-
Je něco špatně v tomto záznamu ?
Electrochemical behavior and determination of rutin on modified carbon paste electrodes
P. Macikova, V. Halouzka, J. Hrbac, P. Bartak, J. Skopalova
Jazyk angličtina Země Anglie, Velká Británie
Typ dokumentu časopisecké články, práce podpořená grantem
NLK
Directory of Open Access Journals
od 2001
Free Medical Journals
od 2000
Hindawi Publishing Open Access
od 2000-01-01
PubMed Central
od 2000
Europe PubMed Central
od 2000
ProQuest Central
od 2012-01-01
Open Access Digital Library
od 2000-01-01 do 2012-01-02
Open Access Digital Library
od 2001-01-01
Open Access Digital Library
od 2011-01-01
Open Access Digital Library
od 2012-01-03
Medline Complete (EBSCOhost)
od 2012-01-01
Health & Medicine (ProQuest)
od 2012-01-01
ROAD: Directory of Open Access Scholarly Resources
od 2001
PubMed
22654602
DOI
10.1100/2012/394756
Knihovny.cz E-zdroje
- MeSH
- elektrochemie metody MeSH
- elektrody MeSH
- Fagopyrum chemie MeSH
- molekulární struktura MeSH
- rutin chemie MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
The performances of ionic liquid (1-hexyl-3-methylimidazolium-bis(trifluoromethylsulfonyl)imide, IL/CPE) and iron phthalocyanine (IP/CPE) modified carbon paste electrodes in electroanalytical determinations of rutin were evaluated and compared to the performance of unmodified carbon paste electrode (CPE). Cyclic voltammetry (CV), differential pulse voltammetry (DPV), differential pulse adsorptive stripping voltammetry (DPAdSV), and amperometry were used for rutin analysis. The best current responses of rutin were obtained at pH 4.0 for all tested techniques. IL/CPE electrode was found to perform best with DPAdSV technique, where a detection limit (LOD) as low as 5 nmol L(-1) of rutin was found. On the other hand, IP/CPE showed itself to be an optimum choice for DPV technique, where LOD of 80 nmol L(-1) was obtained. Analytical applicability of newly prepared electrodes was demonstrated on determination of rutin in the model samples and the extracts of buckwheat seeds. To find an optimum method for buckwheat seeds extraction, a boiling water extraction (BWE), Soxhlet extraction (SE), pressurized solvent extraction (PSE), and supercritical fluid extraction (SFE) were tested.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc12034466
- 003
- CZ-PrNML
- 005
- 20160626101440.0
- 007
- ta
- 008
- 121023s2012 enk f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1100/2012/394756 $2 doi
- 035 __
- $a (PubMed)22654602
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a enk
- 100 1_
- $a Macíková, Pavla $u Regional Centre of Advanced Technologies and Materials, Department of Analytical Chemistry, Faculty of Science, Palacky University, 17 listopadu 12, 771 46 Olomouc, Czech Republic
- 245 10
- $a Electrochemical behavior and determination of rutin on modified carbon paste electrodes / $c P. Macikova, V. Halouzka, J. Hrbac, P. Bartak, J. Skopalova
- 520 9_
- $a The performances of ionic liquid (1-hexyl-3-methylimidazolium-bis(trifluoromethylsulfonyl)imide, IL/CPE) and iron phthalocyanine (IP/CPE) modified carbon paste electrodes in electroanalytical determinations of rutin were evaluated and compared to the performance of unmodified carbon paste electrode (CPE). Cyclic voltammetry (CV), differential pulse voltammetry (DPV), differential pulse adsorptive stripping voltammetry (DPAdSV), and amperometry were used for rutin analysis. The best current responses of rutin were obtained at pH 4.0 for all tested techniques. IL/CPE electrode was found to perform best with DPAdSV technique, where a detection limit (LOD) as low as 5 nmol L(-1) of rutin was found. On the other hand, IP/CPE showed itself to be an optimum choice for DPV technique, where LOD of 80 nmol L(-1) was obtained. Analytical applicability of newly prepared electrodes was demonstrated on determination of rutin in the model samples and the extracts of buckwheat seeds. To find an optimum method for buckwheat seeds extraction, a boiling water extraction (BWE), Soxhlet extraction (SE), pressurized solvent extraction (PSE), and supercritical fluid extraction (SFE) were tested.
- 650 _2
- $a elektrochemie $x metody $7 D004563
- 650 _2
- $a elektrody $7 D004566
- 650 _2
- $a Fagopyrum $x chemie $7 D019612
- 650 _2
- $a molekulární struktura $7 D015394
- 650 _2
- $a rutin $x chemie $7 D012431
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Halouzka, Vladimír $u Department of Physical Chemistry, Faculty of Science, Palacky University, 17. listopadu 12, 771 46 Olomouc, Czech Republic
- 700 1_
- $a Hrbáč, Jan, $d 1972- $7 ola2008434627 $u Department of Physical Chemistry, Faculty of Science, Palacky University, 17. listopadu 12, 771 46 Olomouc, Czech Republic
- 700 1_
- $a Barták, Petr, $d 1973- $7 ola2002157879 $u Regional Centre of Advanced Technologies and Materials, Department of Analytical Chemistry, Faculty of Science, Palacky University, 17. listopadu 12, 771 46 Olomouc, Czech Republic
- 700 1_
- $a Skopalová, Jana, $d 1969- $7 ola2002157976 $u Department of Analytical Chemistry, Faculty of Science, Palacky University, 17. listopadu 12, 771 46 Olomouc, Czech Republic
- 773 0_
- $w MED00181094 $t TheScientificWorldJournal $x 1537-744X $g Roč. 2012(2012), s. 394756
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/22654602 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y p $z 0
- 990 __
- $a 20121023 $b ABA008
- 991 __
- $a 20160626101625 $b ABA008
- 999 __
- $a ok $b bmc $g 956476 $s 791963
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2012 $b 2012 $d 394756 $i 1537-744X $m TheScientificWorldJournal $n ScientificWorldJournal $x MED00181094
- LZP __
- $b NLK122 $a Pubmed-20121023