• Je něco špatně v tomto záznamu ?

Determination of celecoxib in human plasma by liquid chromatography-tandem mass spectrometry

P. Ptáček, J. Klíma, J. Macek

. 2012 ; 899 () : 163-166.

Jazyk angličtina Země Nizozemsko

Typ dokumentu hodnotící studie, časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc12034475

A liquid chromatography-electrospray tandem mass spectrometry method was developed and validated to quantitate celecoxib in human plasma. The assay was based on protein precipitation with methanol and liquid chromatography on a C₁₈ column (55 mm × 2 mm, 3 μm), the mobile phase consisted of methanol-10 mM ammonium acetate (75:25, v/v). Quantification was performed by mass spectrometry in the multiple reaction monitoring mode with negative electrospray ionization at m/z 380→316 and 384→320 for celecoxib and the internal standard celecoxib-D₄, respectively. The lower limit of quantitation was 7.0 ng/ml using 0.1 ml of plasma and linearity was demonstrated up to 1800 ng/ml. Intra-assay and inter-assay precision expressed by relative standard deviation was less than 4% and inaccuracy did not exceed 6% at all levels. The assay was applied to the analysis of samples from a pharmacokinetic study.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc12034475
003      
CZ-PrNML
005      
20160602161455.0
007      
ta
008      
121023s2012 ne f 000 0|eng||
009      
AR
024    7_
$a 10.1016/j.jchromb.2012.05.013 $2 doi
035    __
$a (PubMed)22633154
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a ne
100    1_
$a Ptáček, Pavel $u Pharmakl s.r.o., Seydlerova 2451, CZ-15800 Prague 13, Czech Republic $7 xx0064070
245    10
$a Determination of celecoxib in human plasma by liquid chromatography-tandem mass spectrometry / $c P. Ptáček, J. Klíma, J. Macek
520    9_
$a A liquid chromatography-electrospray tandem mass spectrometry method was developed and validated to quantitate celecoxib in human plasma. The assay was based on protein precipitation with methanol and liquid chromatography on a C₁₈ column (55 mm × 2 mm, 3 μm), the mobile phase consisted of methanol-10 mM ammonium acetate (75:25, v/v). Quantification was performed by mass spectrometry in the multiple reaction monitoring mode with negative electrospray ionization at m/z 380→316 and 384→320 for celecoxib and the internal standard celecoxib-D₄, respectively. The lower limit of quantitation was 7.0 ng/ml using 0.1 ml of plasma and linearity was demonstrated up to 1800 ng/ml. Intra-assay and inter-assay precision expressed by relative standard deviation was less than 4% and inaccuracy did not exceed 6% at all levels. The assay was applied to the analysis of samples from a pharmacokinetic study.
650    _2
$a mladiství $7 D000293
650    _2
$a dospělí $7 D000328
650    _2
$a vysokoúčinná kapalinová chromatografie $x metody $7 D002851
650    _2
$a inhibitory cyklooxygenasy 2 $x krev $7 D052246
650    _2
$a lidé $7 D006801
650    _2
$a mužské pohlaví $7 D008297
650    _2
$a lidé středního věku $7 D008875
650    _2
$a krevní plazma $x chemie $7 D010949
650    _2
$a pyrazoly $x krev $7 D011720
650    _2
$a hmotnostní spektrometrie s elektrosprejovou ionizací $x metody $7 D021241
650    _2
$a sulfonamidy $x krev $7 D013449
650    _2
$a tandemová hmotnostní spektrometrie $x metody $7 D053719
650    _2
$a mladý dospělý $7 D055815
655    _2
$a hodnotící studie $7 D023362
655    _2
$a časopisecké články $7 D016428
700    1_
$a Klíma, Josef $7 jx20050428026 $u Pharmakl s.r.o., Seydlerova 2451, CZ-15800 Prague 13, Czech Republic
700    1_
$a Macek, Jan $7 xx0061837 $u Pharmakl s.r.o., Seydlerova 2451, CZ-15800 Prague 13, Czech Republic
773    0_
$w MED00006642 $t Journal of chromatography. B, Analytical technologies in the biomedical and life sciences $x 1873-376X $g Roč. 899(2012), s. 163-166
856    41
$u https://pubmed.ncbi.nlm.nih.gov/22633154 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y p $z 0
990    __
$a 20121023 $b ABA008
991    __
$a 20160602161229 $b ABA008
999    __
$a ok $b bmc $g 956485 $s 791972
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2012 $b 899 $d 163-166 $i 1873-376X $m Journal of chromatography. B, Analytical technologies in the biomedical and life sciences $n J Chromatogr B Analyt Technol Biomed Life Sci $x MED00006642
LZP    __
$b NLK112 $a Pubmed-20121023

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...