• Je něco špatně v tomto záznamu ?

Role of latency jittering correction in motion-onset VEP amplitude decay during prolonged visual stimulation

J. Kremláček, M. Hulan, M. Kuba, Z. Kubová, J. Langrová, F. Vít, J. Szanyi,

. 2012 ; 124 (3) : 211-23.

Jazyk angličtina Země Nizozemsko

Typ dokumentu časopisecké články, práce podpořená grantem

Perzistentní odkaz   https://www.medvik.cz/link/bmc12034654
E-zdroje Online Plný text

NLK ProQuest Central od 1997-03-01 do Před 1 rokem
Medline Complete (EBSCOhost) od 2011-02-01 do Před 1 rokem
Health & Medicine (ProQuest) od 1997-03-01 do Před 1 rokem

Visual evoked potentials to motion-onset stimulation (M-VEPs) gradually attenuate in amplitude during examination. The observed decline in averaged responses can be caused by decreases in single response magnitudes and/or increased variability in a response delays, that is, latency jittering. To illuminate the origins of the suppression of M-VEPs during stimuli repetition, we used correlation technique to estimate an upper bound of possible latency jittering of single sweeps and we evaluated the effect of its correction on the amplitudes of three M-VEP dominant peaks P1, N2 and P3. During prolonged visual motion stimulation, the variability of corrective latency shifts in the occipital region increased (r = 0.35: 0.44) and the number of single responses corresponding to the average curve declined in occipital and parietal derivations (r = -0.48: -0.62). While the P1 peak amplitude did not exhibit any time-specific behaviour, the N2 amplitude exhibited a significant decay of 29.4% that was partially reduced to 16.6% in the central occipital derivation by the latency jitter and non-correspondence corrections. The strongest attenuation (32.7%) was observed in the P3 amplitude and was less sensitive to the corrections, dropping only to 27.9%. The main part of the response suppression to repeated motion stimulation was caused by amplitude drop and represents non-stationary process that likely correspond to a fatigue model. The rise of variability in latency jitter correction and the reduction in single responses correlated with the M-VEP were significant factors associated with prolonged motion stimulation. The relation of these parameters to a hypothetical veridical response is ambiguous and can be caused by a time shift of the response or by a change of signal-to-noise ratio. Using selective averaging and latency jitter correction, the effect of response suppression was partially removed.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc12034654
003      
CZ-PrNML
005      
20121207094914.0
007      
ta
008      
121023s2012 ne f 000 0|eng||
009      
AR
024    7_
$a 10.1007/s10633-012-9321-6 $2 doi
035    __
$a (PubMed)22431242
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a ne
100    1_
$a Kremláček, J $u Department of Pathophysiology, Faculty of Medicine in Hradec Králové, Charles University in Prague, Prague, Czech Republic. jan.kremlacek@lfhk.cuni.cz
245    10
$a Role of latency jittering correction in motion-onset VEP amplitude decay during prolonged visual stimulation / $c J. Kremláček, M. Hulan, M. Kuba, Z. Kubová, J. Langrová, F. Vít, J. Szanyi,
520    9_
$a Visual evoked potentials to motion-onset stimulation (M-VEPs) gradually attenuate in amplitude during examination. The observed decline in averaged responses can be caused by decreases in single response magnitudes and/or increased variability in a response delays, that is, latency jittering. To illuminate the origins of the suppression of M-VEPs during stimuli repetition, we used correlation technique to estimate an upper bound of possible latency jittering of single sweeps and we evaluated the effect of its correction on the amplitudes of three M-VEP dominant peaks P1, N2 and P3. During prolonged visual motion stimulation, the variability of corrective latency shifts in the occipital region increased (r = 0.35: 0.44) and the number of single responses corresponding to the average curve declined in occipital and parietal derivations (r = -0.48: -0.62). While the P1 peak amplitude did not exhibit any time-specific behaviour, the N2 amplitude exhibited a significant decay of 29.4% that was partially reduced to 16.6% in the central occipital derivation by the latency jitter and non-correspondence corrections. The strongest attenuation (32.7%) was observed in the P3 amplitude and was less sensitive to the corrections, dropping only to 27.9%. The main part of the response suppression to repeated motion stimulation was caused by amplitude drop and represents non-stationary process that likely correspond to a fatigue model. The rise of variability in latency jitter correction and the reduction in single responses correlated with the M-VEP were significant factors associated with prolonged motion stimulation. The relation of these parameters to a hypothetical veridical response is ambiguous and can be caused by a time shift of the response or by a change of signal-to-noise ratio. Using selective averaging and latency jitter correction, the effect of response suppression was partially removed.
650    _2
$a adaptace oční $x fyziologie $7 D000221
650    _2
$a dospělí $7 D000328
650    _2
$a zrakové evokované potenciály $x fyziologie $7 D005074
650    _2
$a ženské pohlaví $7 D005260
650    _2
$a lidé $7 D006801
650    _2
$a mužské pohlaví $7 D008297
650    _2
$a lidé středního věku $7 D008875
650    _2
$a vnímání pohybu $x fyziologie $7 D009039
650    _2
$a rozpoznávání obrazu $x fyziologie $7 D010364
650    _2
$a zrakové korové centrum $x fyziologie $7 D014793
650    _2
$a mladý dospělý $7 D055815
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Hulan, M
700    1_
$a Kuba, M
700    1_
$a Kubová, Z
700    1_
$a Langrová, J
700    1_
$a Vít, F
700    1_
$a Szanyi, J
773    0_
$w MED00010453 $t Documenta ophthalmologica. Advances in ophthalmology $x 1573-2622 $g Roč. 124, č. 3 (2012), s. 211-23
856    41
$u https://pubmed.ncbi.nlm.nih.gov/22431242 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a
990    __
$a 20121023 $b ABA008
991    __
$a 20121207094949 $b ABA008
999    __
$a ok $b bmc $g 956664 $s 792151
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2012 $b 124 $c 3 $d 211-23 $i 1573-2622 $m Documenta ophthalmologica $n Doc Ophthalmol $x MED00010453
LZP    __
$a Pubmed-20121023

Najít záznam

Citační ukazatele

Nahrávání dat ...

    Možnosti archivace