Divergent-flow isoelectric focusing for separation and preparative analysis of peptides
F. Duša, J. Křenková, D. Moravcová, V. Kahle, K. Slais,
Jazyk angličtina Země Německo
Typ dokumentu časopisecké články, práce podpořená grantem
NLK
Medline Complete (EBSCOhost)
od 2012-10-01 do Před 1 rokem
Wiley Online Library (archiv)
od 1999-01-01 do 2012-12-31
PubMed
22740456
DOI
10.1002/elps.201100587
Knihovny.cz E-zdroje
- MeSH
- design vybavení MeSH
- isoelektrická fokusace přístrojové vybavení metody MeSH
- kaseiny chemie MeSH
- peptidové fragmenty analýza chemie izolace a purifikace MeSH
- peptidy analýza izolace a purifikace MeSH
- proteiny analýza izolace a purifikace MeSH
- skot MeSH
- trypsin chemie MeSH
- zvířata MeSH
- Check Tag
- skot MeSH
- zvířata MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
A divergent-flow isoelectric focusing (DF IEF) technique has been applied for the separation and preparative analysis of peptides. The parameters of the developed DF IEF device such as dimension and shape of the separation bed, selection of nonwoven material of the channel, and separation conditions were optimized. The DF IEF device was tested by the separation of a peptide mixture originating from the tryptic digestion of BSA, cytochrome c, and myoglobin. The pH gradient of DF IEF was created by the autofocusing of tryptic peptides themselves without any addition of carrier ampholytes. The focusing process was monitored visually using colored pI markers, and the obtained fractions were analyzed by RP-HPLC and ESI/TOF-MS. DF IEF operating in the autofocusing mode provides an efficient preseparation of peptides, which is comparable with a commercially available MicroRotofor multicompartment electrolyzer and significantly improves sequence coverage of analyzed proteins. The potential of the DF IEF device as an efficient tool for the preparative scale separations was demonstrated by the isolation of caseinomacropeptide (CMP) from a crude whey solution.
Institute of Analytical Chemistry of Academy of Sciences of Czech Republic v v i Brno Czech Republic
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc13000692
- 003
- CZ-PrNML
- 005
- 20130109115502.0
- 007
- ta
- 008
- 130108s2012 gw f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1002/elps.201100587 $2 doi
- 035 __
- $a (PubMed)22740456
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a gw
- 100 1_
- $a Duša, Filip $u Institute of Analytical Chemistry of Academy of Sciences of Czech Republic, v. v. i., Brno, Czech Republic.
- 245 10
- $a Divergent-flow isoelectric focusing for separation and preparative analysis of peptides / $c F. Duša, J. Křenková, D. Moravcová, V. Kahle, K. Slais,
- 520 9_
- $a A divergent-flow isoelectric focusing (DF IEF) technique has been applied for the separation and preparative analysis of peptides. The parameters of the developed DF IEF device such as dimension and shape of the separation bed, selection of nonwoven material of the channel, and separation conditions were optimized. The DF IEF device was tested by the separation of a peptide mixture originating from the tryptic digestion of BSA, cytochrome c, and myoglobin. The pH gradient of DF IEF was created by the autofocusing of tryptic peptides themselves without any addition of carrier ampholytes. The focusing process was monitored visually using colored pI markers, and the obtained fractions were analyzed by RP-HPLC and ESI/TOF-MS. DF IEF operating in the autofocusing mode provides an efficient preseparation of peptides, which is comparable with a commercially available MicroRotofor multicompartment electrolyzer and significantly improves sequence coverage of analyzed proteins. The potential of the DF IEF device as an efficient tool for the preparative scale separations was demonstrated by the isolation of caseinomacropeptide (CMP) from a crude whey solution.
- 650 _2
- $a zvířata $7 D000818
- 650 _2
- $a kaseiny $x chemie $7 D002364
- 650 _2
- $a skot $7 D002417
- 650 _2
- $a design vybavení $7 D004867
- 650 _2
- $a isoelektrická fokusace $x přístrojové vybavení $x metody $7 D007525
- 650 _2
- $a peptidové fragmenty $x analýza $x chemie $x izolace a purifikace $7 D010446
- 650 _2
- $a peptidy $x analýza $x izolace a purifikace $7 D010455
- 650 _2
- $a proteiny $x analýza $x izolace a purifikace $7 D011506
- 650 _2
- $a trypsin $x chemie $7 D014357
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Křenková, Jana
- 700 1_
- $a Moravcová, Dana
- 700 1_
- $a Kahle, Vladislav
- 700 1_
- $a Slais, Karel
- 773 0_
- $w MED00001508 $t Electrophoresis $x 1522-2683 $g Roč. 33, č. 12 (2012), s. 1687-94
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/22740456 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20130108 $b ABA008
- 991 __
- $a 20130109115607 $b ABA008
- 999 __
- $a ok $b bmc $g 963474 $s 798856
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2012 $b 33 $c 12 $d 1687-94 $i 1522-2683 $m Electrophoresis $n Electrophoresis $x MED00001508
- LZP __
- $a Pubmed-20130108