Detail
Článek
Článek online
FT
Medvik - BMČ
  • Je něco špatně v tomto záznamu ?

Discrepancy in ultrasound biometric parameters of the head (HC - head circumference, BPD - biparietal diameter) in breech presented fetuses

M. Lubusky, M. Prochazka, M. Langova, K. Vomackova, L. Cizek

. 2007 ; 151 (2) : 323-326.

Jazyk angličtina Země Česko

Typ dokumentu časopisecké články, práce podpořená grantem

Perzistentní odkaz   https://www.medvik.cz/link/bmc13003594

BACKGROUND: A comparison of fetal ultrasonographic biometric parameters of the head (head circumference - HC, biparietal diameter - BPD) in breech presented fetuses. METHODS: Ultrasound biometry was performed in accordance with the method presented in the reference tables. In all breech presented fetuses, the HC, BPD and FL (femur length) were measured. High-risk and multiple pregnancies were excluded from the study. RESULTS: A total of 111 ultrasonographic biometries were performed between the 31(st) - 38(th) week of gestation. Fetuses in the breech position had a significantly lower BPD compared to HC and FL. The difference between BPD and HC was 16.2 days (95%Cl 14.3-18.1; p = 0.001). Maternal age at delivery was 20 - 36 years (average 28.1; median 28.0). CONCLUSIONS: According to our results, fetuses in the breech position have a significantly lower BPD compared to HC or FL. HC and FL parameters correlate with gestational age. In cases of ultrasonographic biometric discrepancy between BPD and FL, the fetal position should be taken into account. Breech-presented fetuses have an elongated head shape and ultrasound biometrics should evaluate its circumference (HC). It is important to responsibly interpret the results so as not to stress the expecting mother with suspicions of fetal pathology.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc13003594
003      
CZ-PrNML
005      
20130225123131.0
007      
ta
008      
130128s2007 xr dfo f 000 0|eng||
009      
AR
024    7_
$a 10.5507/bp.2007.055 $2 doi
035    __
$a (PubMed)18345272
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xr
100    1_
$a Ľubušký, Marek, $d 1970- $7 xx0073925 $u Department of Obstetrics and Gynecology, Palacky University, Teaching Hospital, Olomouc; Department of Medical Genetics and Fetal Medicine, Palacky University, Teaching Hospital, Olomouc
245    10
$a Discrepancy in ultrasound biometric parameters of the head (HC - head circumference, BPD - biparietal diameter) in breech presented fetuses / $c M. Lubusky, M. Prochazka, M. Langova, K. Vomackova, L. Cizek
520    9_
$a BACKGROUND: A comparison of fetal ultrasonographic biometric parameters of the head (head circumference - HC, biparietal diameter - BPD) in breech presented fetuses. METHODS: Ultrasound biometry was performed in accordance with the method presented in the reference tables. In all breech presented fetuses, the HC, BPD and FL (femur length) were measured. High-risk and multiple pregnancies were excluded from the study. RESULTS: A total of 111 ultrasonographic biometries were performed between the 31(st) - 38(th) week of gestation. Fetuses in the breech position had a significantly lower BPD compared to HC and FL. The difference between BPD and HC was 16.2 days (95%Cl 14.3-18.1; p = 0.001). Maternal age at delivery was 20 - 36 years (average 28.1; median 28.0). CONCLUSIONS: According to our results, fetuses in the breech position have a significantly lower BPD compared to HC or FL. HC and FL parameters correlate with gestational age. In cases of ultrasonographic biometric discrepancy between BPD and FL, the fetal position should be taken into account. Breech-presented fetuses have an elongated head shape and ultrasound biometrics should evaluate its circumference (HC). It is important to responsibly interpret the results so as not to stress the expecting mother with suspicions of fetal pathology.
650    _2
$a antropometrie $7 D000886
650    _2
$a poloha plodu koncem pánevním $x patologie $7 D001946
650    _2
$a kefalometrie $7 D002508
650    _2
$a ženské pohlaví $7 D005260
650    _2
$a plod $x anatomie a histologie $7 D005333
650    _2
$a hlava $x ultrasonografie $7 D006257
650    _2
$a lidé $7 D006801
650    _2
$a těhotenství $7 D011247
650    _2
$a ultrasonografie prenatální $7 D016216
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Procházka, Martin, $7 xx0019288 $u Department of Obstetrics and Gynecology, Palacky University, Teaching Hospital, Olomouc $d 1970-
700    1_
$a Langová, Martina. $7 _BN004128 $u Department of Obstetrics and Gynecology, Palacky University, Teaching Hospital, Olomouc
700    1_
$a Vomáčková, Katherine $7 xx0142837 $u Department of Obstetrics and Gynecology, Palacky University, Teaching Hospital, Olomouc
700    1_
$a Čížek, Luděk, $d 1974- $7 xx0060784 $u Department of Preventive Medicine, Palacky University, Olomouc
773    0_
$w MED00012606 $t Biomedical papers of the Medical Faculty of the University Palacký, Olomouc, Czech Republic $x 1213-8118 $g Roč. 151, č. 2 (2007), s. 323-326
910    __
$a ABA008 $b A 1502 $c sign $y 3 $z 0
990    __
$a 20130128 $b ABA008
991    __
$a 20130225123329 $b ABA008
999    __
$a ok $b bmc $g 966250 $s 801789
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2007 $b 151 $c 2 $d 323-326 $i 1213-8118 $m Biomedical papers of the Medical Faculty of the University Palacký, Olomouc Czech Republic $n Biomed. Pap. Fac. Med. Palacký Univ. Olomouc Czech Repub. (Print) $x MED00012606
LZP    __
$b NLK111 $a Pubmed-20130128

Najít záznam

Citační ukazatele

Pouze přihlášení uživatelé

Možnosti archivace

Nahrávání dat ...