             Je něco špatně v tomto záznamu ?
 
Possibilities of experimental verification of the validity of urethral pressure profilometry
F. Zatura, J. Rosenberg
Jazyk angličtina Země Česko
Typ dokumentu časopisecké články, práce podpořená grantem, validační studie
        Grantová podpora
          
              NR7840 
          
      MZ0   
          
            CEP - Centrální evidence projektů  
          
      
      
  Digitální knihovna  NLK 
   
   
      Plný text - Část
   
   
   
   
      Zdroj
   
   
 NLK 
   
      Directory of Open Access Journals
   
    od 2001
   
      Free Medical Journals
   
    od 1998
   
      ROAD: Directory of Open Access Scholarly Resources
   
    od 2001
    
    PubMed
          
           17426804
           
          
          
    DOI
          
           10.5507/bp.2006.053
           
          
          
  
    Knihovny.cz E-zdroje
    
  
              
      
- MeSH
- katetrizace močového měchýře MeSH
- reprodukovatelnost výsledků MeSH
- skot MeSH
- techniky in vitro MeSH
- tlak MeSH
- uretra fyziologie MeSH
- urodynamika MeSH
- zvířata MeSH
- Check Tag
- mužské pohlaví MeSH
- skot MeSH
- zvířata MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- validační studie MeSH
Objectives: The aim is to define conditions for exact measurement of urethral pressure profile, to prepare an aparatus and fabricate an artificial urethra for testing measuring catethers. To examine it's qualities by experiment. METHODS: We designed a measuring appliance and a specialized software for measuring and evaluating. An experimental phantom of urethra, made from a part of bull's urethra, was used for testing of measurement's validity with use of different measuring catethers. Measurements were 10x repeated within the same position of the catether. Reproducibility of the measurement and stability of the experimental model was tested. RESULTS: Measuring urethra and experimental phantom of urethra succeeded, it was possible to make well reproducible measurements with different measuring catethers and to evaluate their metrologic abilities and limits. Results of our measurements confirmed appointed theoretical conditions of the measurement. CONCLUSION: Measurements proved that it is possible to simulate the conditions that are similar to physiological conditions and that it is possible to test metrological qualities of compressive profilometry of urethra.
Department of Mechanical Engineering University of West Bohemia Pilsen
Faculty of Medicine and Dentistry Palacky University Olomouc
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc13003653
- 003
- CZ-PrNML
- 005
- 20130731141420.0
- 007
- ta
- 008
- 130128s2006 xr fdo f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.5507/bp.2006.053 $2 doi
- 035 __
- $a (PubMed)17426804
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xr
- 100 1_
- $a Záťura, František, $d 1951- $7 jo2002107483 $u Faculty of Medicine and Dentistry, Palacky University, Olomouc
- 245 10
- $a Possibilities of experimental verification of the validity of urethral pressure profilometry / $c F. Zatura, J. Rosenberg
- 520 9_
- $a Objectives: The aim is to define conditions for exact measurement of urethral pressure profile, to prepare an aparatus and fabricate an artificial urethra for testing measuring catethers. To examine it's qualities by experiment. METHODS: We designed a measuring appliance and a specialized software for measuring and evaluating. An experimental phantom of urethra, made from a part of bull's urethra, was used for testing of measurement's validity with use of different measuring catethers. Measurements were 10x repeated within the same position of the catether. Reproducibility of the measurement and stability of the experimental model was tested. RESULTS: Measuring urethra and experimental phantom of urethra succeeded, it was possible to make well reproducible measurements with different measuring catethers and to evaluate their metrologic abilities and limits. Results of our measurements confirmed appointed theoretical conditions of the measurement. CONCLUSION: Measurements proved that it is possible to simulate the conditions that are similar to physiological conditions and that it is possible to test metrological qualities of compressive profilometry of urethra.
- 650 _2
- $a zvířata $7 D000818
- 650 _2
- $a skot $7 D002417
- 650 _2
- $a mužské pohlaví $7 D008297
- 650 _2
- $a tlak $7 D011312
- 650 _2
- $a reprodukovatelnost výsledků $7 D015203
- 650 _2
- $a uretra $x fyziologie $7 D014521
- 650 _2
- $a katetrizace močového měchýře $7 D014546
- 650 _2
- $a urodynamika $7 D014563
- 650 _2
- $a techniky in vitro $7 D066298
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 655 _2
- $a validační studie $7 D023361
- 700 1_
- $a Rosenberg, Josef, $d 1940- $7 ola2004220068 $u Department of Mechanical Engineering, University of West Bohemia, Pilsen
- 773 0_
- $w MED00012606 $t Biomedical papers of the Medical Faculty of the University Palacký, Olomouc, Czech Republic $x 1213-8118 $g Roč. 150, č. 2 (2006), s. 345-351
- 910 __
- $a ABA008 $b A 1502 $c sign $y 3 $z 0
- 990 __
- $a 20130128 $b ABA008
- 991 __
- $a 20130731141917 $b ABA008
- 999 __
- $a ok $b bmc $g 966309 $s 801848
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2006 $b 150 $c 2 $d 345-351 $i 1213-8118 $m Biomedical papers of the Medical Faculty of the University Palacký, Olomouc Czech Republic $n Biomed. Pap. Fac. Med. Palacký Univ. Olomouc Czech Repub. (Print) $x MED00012606
- GRA __
- $a NR7840 $p MZ0
- LZP __
- $b NLK111 $a Pubmed-20130128