-
Je něco špatně v tomto záznamu ?
Case report: restoration of edentulous mandible with 4 BOI implants in an immediate load procedure
S. Ihde, M. Eber
Jazyk angličtina Země Česko
Typ dokumentu kazuistiky, časopisecké články
NLK
Directory of Open Access Journals
od 2001
Free Medical Journals
od 1998
ROAD: Directory of Open Access Scholarly Resources
od 2001
PubMed
15744373
DOI
10.5507/bp.2004.036
Knihovny.cz E-zdroje
- MeSH
- čelist bezzubá chirurgie MeSH
- endoseální implantace zubů MeSH
- lidé MeSH
- mandibula chirurgie MeSH
- senioři MeSH
- zubní náhrada ve spojení s implantáty MeSH
- Check Tag
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- Publikační typ
- časopisecké články MeSH
- kazuistiky MeSH
Dental implants for insertion from the lateral aspects of the jaw bone have been described repeatedly, since 1972. Long term results have been reported. Due to their design, BOI-Implants (basal osseointegration) can be installed even in those cases, where the vertical bone supply is reduced. This applies to the distal areas of the maxilla and the mandible. Furthermore, BOI-implants allow immediate loading as long as a balanced masticatory function can be achieved and maintained. This paper reports on the steps taken to install a full lower bridge in 4 BOI-implants and restoration in a patient with a circular bridge. The bridge was made from CoCr-Alloy and covered with acrylic resin. This treatment technique reduces costs and treatment time by about 50% compared to conventional techniques.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc13003816
- 003
- CZ-PrNML
- 005
- 20130219150114.0
- 007
- ta
- 008
- 130128s2004 xr do f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.5507/bp.2004.036 $2 doi
- 035 __
- $a (PubMed)15744373
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xr
- 100 1_
- $a Ihde, Stefan $u Zahnärztliche Klinik Gommiswald AG, Dorfplatz 11, Gommiswald, CH-8737. dr.ihde@bluewin.ch
- 245 10
- $a Case report: restoration of edentulous mandible with 4 BOI implants in an immediate load procedure / $c S. Ihde, M. Eber
- 520 9_
- $a Dental implants for insertion from the lateral aspects of the jaw bone have been described repeatedly, since 1972. Long term results have been reported. Due to their design, BOI-Implants (basal osseointegration) can be installed even in those cases, where the vertical bone supply is reduced. This applies to the distal areas of the maxilla and the mandible. Furthermore, BOI-implants allow immediate loading as long as a balanced masticatory function can be achieved and maintained. This paper reports on the steps taken to install a full lower bridge in 4 BOI-implants and restoration in a patient with a circular bridge. The bridge was made from CoCr-Alloy and covered with acrylic resin. This treatment technique reduces costs and treatment time by about 50% compared to conventional techniques.
- 650 _2
- $a senioři $7 D000368
- 650 _2
- $a endoseální implantace zubů $7 D003758
- 650 _2
- $a zubní náhrada ve spojení s implantáty $7 D019094
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a čelist bezzubá $x chirurgie $7 D007575
- 650 _2
- $a mužské pohlaví $7 D008297
- 650 _2
- $a mandibula $x chirurgie $7 D008334
- 655 _2
- $a kazuistiky $7 D002363
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Eber, Miroslav, $d 1939-2018 $7 nlk19990073126 $u Clinic of Dentistry, Faculty of Medicine, Palacky University, Palackeho 12, 772 00 Olomouc, Czech Republic
- 773 0_
- $w MED00012606 $t Biomedical papers of the Medical Faculty of the University Palacký, Olomouc, Czech Republic $x 1213-8118 $g Roč. 148, č. 2 (2004), s. 195-198
- 910 __
- $a ABA008 $b A 1502 $c sign $y 3 $z 0
- 990 __
- $a 20130128 $b ABA008
- 991 __
- $a 20130219150304 $b ABA008
- 999 __
- $a ok $b bmc $g 966469 $s 802011
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2004 $b 148 $c 2 $d 195-198 $i 1213-8118 $m Biomedical papers of the Medical Faculty of the University Palacký, Olomouc Czech Republic $n Biomed. Pap. Fac. Med. Palacký Univ. Olomouc Czech Repub. (Print) $x MED00012606
- LZP __
- $b NLK138 $a Pubmed-20130128