Case report: restoration of edentulous mandible with 4 BOI implants in an immediate load procedure

S. Ihde, M. Eber

. 2004 ; 148 (2) : 195-198.

Jazyk angličtina Země Česko

Typ dokumentu kazuistiky, časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc13003816

Dental implants for insertion from the lateral aspects of the jaw bone have been described repeatedly, since 1972. Long term results have been reported. Due to their design, BOI-Implants (basal osseointegration) can be installed even in those cases, where the vertical bone supply is reduced. This applies to the distal areas of the maxilla and the mandible. Furthermore, BOI-implants allow immediate loading as long as a balanced masticatory function can be achieved and maintained. This paper reports on the steps taken to install a full lower bridge in 4 BOI-implants and restoration in a patient with a circular bridge. The bridge was made from CoCr-Alloy and covered with acrylic resin. This treatment technique reduces costs and treatment time by about 50% compared to conventional techniques.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc13003816
003      
CZ-PrNML
005      
20130219150114.0
007      
ta
008      
130128s2004 xr do f 000 0|eng||
009      
AR
024    7_
$a 10.5507/bp.2004.036 $2 doi
035    __
$a (PubMed)15744373
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xr
100    1_
$a Ihde, Stefan $u Zahnärztliche Klinik Gommiswald AG, Dorfplatz 11, Gommiswald, CH-8737. dr.ihde@bluewin.ch
245    10
$a Case report: restoration of edentulous mandible with 4 BOI implants in an immediate load procedure / $c S. Ihde, M. Eber
520    9_
$a Dental implants for insertion from the lateral aspects of the jaw bone have been described repeatedly, since 1972. Long term results have been reported. Due to their design, BOI-Implants (basal osseointegration) can be installed even in those cases, where the vertical bone supply is reduced. This applies to the distal areas of the maxilla and the mandible. Furthermore, BOI-implants allow immediate loading as long as a balanced masticatory function can be achieved and maintained. This paper reports on the steps taken to install a full lower bridge in 4 BOI-implants and restoration in a patient with a circular bridge. The bridge was made from CoCr-Alloy and covered with acrylic resin. This treatment technique reduces costs and treatment time by about 50% compared to conventional techniques.
650    _2
$a senioři $7 D000368
650    _2
$a endoseální implantace zubů $7 D003758
650    _2
$a zubní náhrada ve spojení s implantáty $7 D019094
650    _2
$a lidé $7 D006801
650    _2
$a čelist bezzubá $x chirurgie $7 D007575
650    _2
$a mužské pohlaví $7 D008297
650    _2
$a mandibula $x chirurgie $7 D008334
655    _2
$a kazuistiky $7 D002363
655    _2
$a časopisecké články $7 D016428
700    1_
$a Eber, Miroslav, $d 1939-2018 $7 nlk19990073126 $u Clinic of Dentistry, Faculty of Medicine, Palacky University, Palackeho 12, 772 00 Olomouc, Czech Republic
773    0_
$w MED00012606 $t Biomedical papers of the Medical Faculty of the University Palacký, Olomouc, Czech Republic $x 1213-8118 $g Roč. 148, č. 2 (2004), s. 195-198
910    __
$a ABA008 $b A 1502 $c sign $y 3 $z 0
990    __
$a 20130128 $b ABA008
991    __
$a 20130219150304 $b ABA008
999    __
$a ok $b bmc $g 966469 $s 802011
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2004 $b 148 $c 2 $d 195-198 $i 1213-8118 $m Biomedical papers of the Medical Faculty of the University Palacký, Olomouc Czech Republic $n Biomed. Pap. Fac. Med. Palacký Univ. Olomouc Czech Repub. (Print) $x MED00012606
LZP    __
$b NLK138 $a Pubmed-20130128

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...