-
Something wrong with this record ?
Robot-assisted navigation in atrial fibrillation ablation—Of any benefits?
Jan Petrů, Jan Škoda
Language English Country Czech Republic
Document type Review, Research Support, Non-U.S. Gov't
- Keywords
- dálková navigace,
- MeSH
- Atrial Fibrillation * surgery MeSH
- Catheter Ablation * methods MeSH
- Humans MeSH
- Robotics * methods MeSH
- Treatment Outcome MeSH
- Check Tag
- Humans MeSH
- Publication type
- Research Support, Non-U.S. Gov't MeSH
- Review MeSH
In recent years, catheter ablation has been established as a safe and effective treatment for atrial fibrillation (AF). The benefits of robotic catheter navigation technology and techniques for AF ablation are currently a frequent topic of discussion. Most clinical trials have suggested that robotic ablation is (at least) as effective as the manual approach. The most important potential advantages of robotic ablation include excellent catheter stability and accuracy of its movement, reduced fluoroscopic time, catheter contact monitoring, improved comfort of the operator during the procedure as they can sit most of the time unexposed to radiation and, last but not least, a very short learning curve potentially allowing for more complicated procedures (persistent forms of AF, structural ventricular tachycardias, congenital heart disease).
Literatura
- 000
- 00000naa a2200000 a 4500
- 001
- bmc13008811
- 003
- CZ-PrNML
- 005
- 20130320104123.0
- 007
- ta
- 008
- 130305s2012 xr fo f 000 0eng||
- 009
- AR
- 024 7_
- $2 doi $a 10.1016/j.crvasa.2012.11.016
- 040 __
- $a ABA008 $d ABA008 $e AACR2 $b cze
- 041 0_
- $a eng $b cze
- 044 __
- $a xr
- 100 1_
- $a Petrů, Jan. $7 xx0312278 $u Department of Cardiology, Na Homolce Hospital, Prague, Czech Republic
- 245 10
- $a Robot-assisted navigation in atrial fibrillation ablation—Of any benefits? / $c Jan Petrů, Jan Škoda
- 504 __
- $a Literatura
- 520 9_
- $a In recent years, catheter ablation has been established as a safe and effective treatment for atrial fibrillation (AF). The benefits of robotic catheter navigation technology and techniques for AF ablation are currently a frequent topic of discussion. Most clinical trials have suggested that robotic ablation is (at least) as effective as the manual approach. The most important potential advantages of robotic ablation include excellent catheter stability and accuracy of its movement, reduced fluoroscopic time, catheter contact monitoring, improved comfort of the operator during the procedure as they can sit most of the time unexposed to radiation and, last but not least, a very short learning curve potentially allowing for more complicated procedures (persistent forms of AF, structural ventricular tachycardias, congenital heart disease).
- 650 12
- $a fibrilace síní $x chirurgie $7 D001281
- 650 12
- $a katetrizační ablace $x metody $7 D017115
- 650 12
- $a robotika $x metody $7 D012371
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a výsledek terapie $7 D016896
- 650 _2
- $a lidé $7 D006801
- 653 00
- $a dálková navigace
- 655 _2
- $a přehledy $7 D016454
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Škoda, Jan $7 xx0105434 $u Department of Cardiology, Na Homolce Hospital, Prague, Czech Republic
- 773 0_
- $t Cor et vasa $x 0010-8650 $g Roč. 54, č. 11-12 [6] (2012), s. 597-602 (e e408-e413) $w MED00010972
- 856 41
- $u https://e-coretvasa.cz/pdfs/cor/2012/11/16.pdf $y domovská stránka časopisu
- 910 __
- $a ABA008 $b A 2980 $c 438 $y 3 $z 0
- 990 __
- $a 20130304171100 $b ABA008
- 991 __
- $a 20130320104341 $b ABA008
- 999 __
- $a ok $b bmc $g 971520 $s 807059
- BAS __
- $a 3
- BMC __
- $a 2012 $b 54 $c 11-12 $d 597-602 $f e408-e413 $g 6 $i 0010-8650 $m Cor et Vasa (Brno) $n Cor Vasa (Brno Print) $x MED00010972
- LZP __
- $c NLK125 $d 20130320 $a NLK 2013-14/dk