Detail
Článek
Článek online
FT
Medvik - BMČ
  • Je něco špatně v tomto záznamu ?

Robot-assisted navigation in atrial fibrillation ablation—Of any benefits?

Jan Petrů, Jan Škoda

. 2012 ; 54 (11-12) : 597-602. [epub] 6 : e408-e413

Jazyk angličtina Země Česko

Typ dokumentu přehledy, práce podpořená grantem

Perzistentní odkaz   https://www.medvik.cz/link/bmc13008811

In recent years, catheter ablation has been established as a safe and effective treatment for atrial fibrillation (AF). The benefits of robotic catheter navigation technology and techniques for AF ablation are currently a frequent topic of discussion. Most clinical trials have suggested that robotic ablation is (at least) as effective as the manual approach. The most important potential advantages of robotic ablation include excellent catheter stability and accuracy of its movement, reduced fluoroscopic time, catheter contact monitoring, improved comfort of the operator during the procedure as they can sit most of the time unexposed to radiation and, last but not least, a very short learning curve potentially allowing for more complicated procedures (persistent forms of AF, structural ventricular tachycardias, congenital heart disease).

Bibliografie atd.

Literatura

000      
00000naa a2200000 a 4500
001      
bmc13008811
003      
CZ-PrNML
005      
20130320104123.0
007      
ta
008      
130305s2012 xr fo f 000 0eng||
009      
AR
024    7_
$2 doi $a 10.1016/j.crvasa.2012.11.016
040    __
$a ABA008 $d ABA008 $e AACR2 $b cze
041    0_
$a eng $b cze
044    __
$a xr
100    1_
$a Petrů, Jan. $7 xx0312278 $u Department of Cardiology, Na Homolce Hospital, Prague, Czech Republic
245    10
$a Robot-assisted navigation in atrial fibrillation ablation—Of any benefits? / $c Jan Petrů, Jan Škoda
504    __
$a Literatura
520    9_
$a In recent years, catheter ablation has been established as a safe and effective treatment for atrial fibrillation (AF). The benefits of robotic catheter navigation technology and techniques for AF ablation are currently a frequent topic of discussion. Most clinical trials have suggested that robotic ablation is (at least) as effective as the manual approach. The most important potential advantages of robotic ablation include excellent catheter stability and accuracy of its movement, reduced fluoroscopic time, catheter contact monitoring, improved comfort of the operator during the procedure as they can sit most of the time unexposed to radiation and, last but not least, a very short learning curve potentially allowing for more complicated procedures (persistent forms of AF, structural ventricular tachycardias, congenital heart disease).
650    12
$a fibrilace síní $x chirurgie $7 D001281
650    12
$a katetrizační ablace $x metody $7 D017115
650    12
$a robotika $x metody $7 D012371
650    _2
$a lidé $7 D006801
650    _2
$a výsledek terapie $7 D016896
650    _2
$a lidé $7 D006801
653    00
$a dálková navigace
655    _2
$a přehledy $7 D016454
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Škoda, Jan $7 xx0105434 $u Department of Cardiology, Na Homolce Hospital, Prague, Czech Republic
773    0_
$t Cor et vasa $x 0010-8650 $g Roč. 54, č. 11-12 [6] (2012), s. 597-602 (e e408-e413) $w MED00010972
856    41
$u https://e-coretvasa.cz/pdfs/cor/2012/11/16.pdf $y domovská stránka časopisu
910    __
$a ABA008 $b A 2980 $c 438 $y 3 $z 0
990    __
$a 20130304171100 $b ABA008
991    __
$a 20130320104341 $b ABA008
999    __
$a ok $b bmc $g 971520 $s 807059
BAS    __
$a 3
BMC    __
$a 2012 $b 54 $c 11-12 $d 597-602 $f e408-e413 $g 6 $i 0010-8650 $m Cor et Vasa (Brno) $n Cor Vasa (Brno Print) $x MED00010972
LZP    __
$c NLK125 $d 20130320 $a NLK 2013-14/dk

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...