Enhanced capabilities of separation in Sequential Injection Chromatography--fused-core particle column and its comparison with narrow-bore monolithic column
P. Chocholouš, L. Kosařová, D. Satínský, H. Sklenářová, P. Solich,
Jazyk angličtina Země Anglie, Velká Británie
Typ dokumentu časopisecké články, práce podpořená grantem
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
In the Sequential Injection Chromatography (SIC) only monolithic columns for chromatographic separations have been used so far. This article presents the first use of fused-core particle packed column in an attempt to extend of the chromatographic capabilities of the SIC system. A new fused-core particle column (2.7 μm) Ascentis(®) Express C18 (Supelco™ Analytical) 30 mm × 4.6 mm brings high separation efficiency within flow rates and pressures comparable to monolithic column Chromolith(®) Performance RP-18e 100-3 (Merck(®)) 100 mm × 3 mm. Both columns matches the conditions of the commercially produced SIC system - SIChrom™ (8-port high-pressure selection valve and medium-pressure Sapphire™ syringe pump with 4 mL reservoir - maximal work pressure 1000 PSI) (FIAlab(®), USA). The system was tested by the separation of four estrogens with similar structure and an internal standard - ethylparaben. The mobile phase composed of acetonitrile/water (40/60 (v/v)) was pumped isocratic at flow rate 0.48 mL min(-1). Spectrophotometric detection was performed at wavelength of 225 nm and injected volume of sample solutions was 10 μL. The chromatographic characteristics of both columns were compared. Obtained results and conclusions have shown that both fused-core particle column and longer narrow shaped monolithic column bring benefits into the SIC method.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc13015850
- 003
- CZ-PrNML
- 005
- 20130424134929.0
- 007
- ta
- 008
- 130424s2011 enk f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1016/j.talanta.2011.05.027 $2 doi
- 035 __
- $a (PubMed)21726748
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a enk
- 100 1_
- $a Chocholouš, Petr $u Department of Analytical Chemistry, Faculty of Pharmacy, Charles University, Heyrovského 1203, 500 05 Hradec Králové, Czech Republic. petr.chocholous@faf.cuni.cz
- 245 10
- $a Enhanced capabilities of separation in Sequential Injection Chromatography--fused-core particle column and its comparison with narrow-bore monolithic column / $c P. Chocholouš, L. Kosařová, D. Satínský, H. Sklenářová, P. Solich,
- 520 9_
- $a In the Sequential Injection Chromatography (SIC) only monolithic columns for chromatographic separations have been used so far. This article presents the first use of fused-core particle packed column in an attempt to extend of the chromatographic capabilities of the SIC system. A new fused-core particle column (2.7 μm) Ascentis(®) Express C18 (Supelco™ Analytical) 30 mm × 4.6 mm brings high separation efficiency within flow rates and pressures comparable to monolithic column Chromolith(®) Performance RP-18e 100-3 (Merck(®)) 100 mm × 3 mm. Both columns matches the conditions of the commercially produced SIC system - SIChrom™ (8-port high-pressure selection valve and medium-pressure Sapphire™ syringe pump with 4 mL reservoir - maximal work pressure 1000 PSI) (FIAlab(®), USA). The system was tested by the separation of four estrogens with similar structure and an internal standard - ethylparaben. The mobile phase composed of acetonitrile/water (40/60 (v/v)) was pumped isocratic at flow rate 0.48 mL min(-1). Spectrophotometric detection was performed at wavelength of 225 nm and injected volume of sample solutions was 10 μL. The chromatographic characteristics of both columns were compared. Obtained results and conclusions have shown that both fused-core particle column and longer narrow shaped monolithic column bring benefits into the SIC method.
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Kosařová, Lucie $u -
- 700 1_
- $a Satínský, Dalibor $u -
- 700 1_
- $a Sklenářová, Hana $u -
- 700 1_
- $a Solich, Petr $u -
- 773 0_
- $w MED00004484 $t Talanta $x 1873-3573 $g Roč. 85, č. 2 (2011), s. 1129-34
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/21726748 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20130424 $b ABA008
- 991 __
- $a 20130424135216 $b ABA008
- 999 __
- $a ind $b bmc $g 979051 $s 814171
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2011 $b 85 $c 2 $d 1129-34 $i 1873-3573 $m Talanta $n Talanta $x MED00004484
- LZP __
- $a Pubmed-20130424