-
Something wrong with this record ?
Direct analysis in real time high-resolution mass spectrometry for high-throughput analysis of antiparasitic veterinary drugs in feed and food
A. Martínez-Villalba, L. Vaclavik, E. Moyano, MT. Galceran, J. Hajslova,
Language English Country England, Great Britain
Document type Journal Article, Research Support, Non-U.S. Gov't
PubMed
23280979
DOI
10.1002/rcm.6466
Knihovny.cz E-resources
- MeSH
- Antiparasitic Agents analysis chemistry MeSH
- Benzimidazoles analysis chemistry MeSH
- Mass Spectrometry methods MeSH
- Animal Feed analysis MeSH
- Milk chemistry MeSH
- High-Throughput Screening Assays methods MeSH
- Cattle MeSH
- Veterinary Drugs analysis chemistry MeSH
- Animals MeSH
- Check Tag
- Cattle MeSH
- Animals MeSH
- Publication type
- Journal Article MeSH
- Research Support, Non-U.S. Gov't MeSH
RATIONALE: Direct analysis in real time (DART) is a novel ionization technique that has been demonstrated in numerous applications as a useful tool for fast and convenient mass spectrometry (MS)-based analysis of complex samples. In this study, the feasibility of DART ionization coupled to a high-resolution mass spectrometer utilizing an orbitrap mass analyzer (orbitrap MS) for high-throughput analysis of antiparasitic veterinary drugs was explored. METHODS: To obtain the best DART-orbitrap MS performance, stepwise optimization of instrumental parameter settings, such as ionization gas temperature and mass resolving power, was performed. The optimized method was applied to feed and bovine milk samples previously extracted following a QuEChERS-like strategy. RESULTS: Most antiparasitic drugs could be analyzed following the described method. Positive DART ionization provided the protonated molecules [M+H](+); in negative DART ion mode, deprotonated molecules [M-H](-) were observed. As an exception, polyether ionophores could be observed as the sodiated adducts [M+Na](+). Samples of milk and feed were extracted using a modified QuEChERS method for the determination of benzimidazoles and coccidiostats respectively and quantification was carried out by matrix-matched calibration curves. CONCLUSIONS: The combination of an analysis time of less than 1 min per sample and the possibility to acquire accurate masses under high mass resolving power (HR) makes the DART-HRMS technique an effective tool for rapid qualitative screening of antiparasitic veterinary drugs. Additionally, the results obtained in this study demonstrated the feasibility of this approach to quantify target analytes at levels down to 1 µg kg(-1) for benzimidazolic compounds in milk and 0.25 mg kg(-1) for coccidiostats in chicken feed.
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc13024034
- 003
- CZ-PrNML
- 005
- 20130709104825.0
- 007
- ta
- 008
- 130703s2013 enk f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1002/rcm.6466 $2 doi
- 035 __
- $a (PubMed)23280979
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a enk
- 100 1_
- $a Martínez-Villalba, Anna $u Institute of Chemical Technology Prague, Faculty of Food and Biochemical Technology, Department of Food Chemistry and Nutrition, Technická 5, 16628, Prague 6, Czech Republic.
- 245 10
- $a Direct analysis in real time high-resolution mass spectrometry for high-throughput analysis of antiparasitic veterinary drugs in feed and food / $c A. Martínez-Villalba, L. Vaclavik, E. Moyano, MT. Galceran, J. Hajslova,
- 520 9_
- $a RATIONALE: Direct analysis in real time (DART) is a novel ionization technique that has been demonstrated in numerous applications as a useful tool for fast and convenient mass spectrometry (MS)-based analysis of complex samples. In this study, the feasibility of DART ionization coupled to a high-resolution mass spectrometer utilizing an orbitrap mass analyzer (orbitrap MS) for high-throughput analysis of antiparasitic veterinary drugs was explored. METHODS: To obtain the best DART-orbitrap MS performance, stepwise optimization of instrumental parameter settings, such as ionization gas temperature and mass resolving power, was performed. The optimized method was applied to feed and bovine milk samples previously extracted following a QuEChERS-like strategy. RESULTS: Most antiparasitic drugs could be analyzed following the described method. Positive DART ionization provided the protonated molecules [M+H](+); in negative DART ion mode, deprotonated molecules [M-H](-) were observed. As an exception, polyether ionophores could be observed as the sodiated adducts [M+Na](+). Samples of milk and feed were extracted using a modified QuEChERS method for the determination of benzimidazoles and coccidiostats respectively and quantification was carried out by matrix-matched calibration curves. CONCLUSIONS: The combination of an analysis time of less than 1 min per sample and the possibility to acquire accurate masses under high mass resolving power (HR) makes the DART-HRMS technique an effective tool for rapid qualitative screening of antiparasitic veterinary drugs. Additionally, the results obtained in this study demonstrated the feasibility of this approach to quantify target analytes at levels down to 1 µg kg(-1) for benzimidazolic compounds in milk and 0.25 mg kg(-1) for coccidiostats in chicken feed.
- 650 _2
- $a krmivo pro zvířata $x analýza $7 D000821
- 650 _2
- $a zvířata $7 D000818
- 650 _2
- $a antiparazitární látky $x analýza $x chemie $7 D000977
- 650 _2
- $a benzimidazoly $x analýza $x chemie $7 D001562
- 650 _2
- $a skot $7 D002417
- 650 _2
- $a rychlé screeningové testy $x metody $7 D057166
- 650 _2
- $a hmotnostní spektrometrie $x metody $7 D013058
- 650 _2
- $a mléko $x chemie $7 D008892
- 650 _2
- $a veterinární léky $x analýza $x chemie $7 D019155
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Vaclavik, Lukas $u -
- 700 1_
- $a Moyano, Encarnación $u -
- 700 1_
- $a Galceran, Maria Teresa $u -
- 700 1_
- $a Hajslova, Jana $u -
- 773 0_
- $w MED00004050 $t Rapid communications in mass spectrometry : RCM $x 1097-0231 $g Roč. 27, č. 3 (2013), s. 467-75
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/23280979 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20130703 $b ABA008
- 991 __
- $a 20130709105247 $b ABA008
- 999 __
- $a ok $b bmc $g 987714 $s 822414
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2013 $b 27 $c 3 $d 467-75 $i 1097-0231 $m Rapid communications in mass spectrometry $n Rapid Commun Mass Spectrom $x MED00004050
- LZP __
- $a Pubmed-20130703