-
Je něco špatně v tomto záznamu ?
Cross-linker effects on the separation efficiency on (poly)methacrylate capillary monolithic columns. Part I. Reversed-phase liquid chromatography
P. Jandera, M. Staňková, V. Škeříková, J. Urban,
Jazyk angličtina Země Nizozemsko
Typ dokumentu časopisecké články, práce podpořená grantem
- MeSH
- benzenové deriváty izolace a purifikace MeSH
- chromatografie s reverzní fází přístrojové vybavení MeSH
- kyseliny polymethakrylové chemie MeSH
- polymerizace MeSH
- poréznost MeSH
- proteiny izolace a purifikace MeSH
- reagencia zkříženě vázaná chemie MeSH
- reprodukovatelnost výsledků MeSH
- skot MeSH
- zvířata MeSH
- Check Tag
- skot MeSH
- zvířata MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
We synthesized 8 polymethacrylate monolithic capillary columns using laurylmethacrylate functional monomer and various cross-linking monomers differing in the polarity and size. The efficiency of monolithic columns for low-molecular compounds significantly improved with increasing number of repeat non-polar methylene groups in the cross-linker molecules, correlating with greater proportion of small pores with size less than 50 nm. The best efficiency with HETP=25 μm for alkylbenzenes was achieved for columns prepared using hexamethylene dimethacrylate (HEDMA). Columns prepared with polar (poly)oxyethylene dimethacrylate cross-linkers show also improved efficiency with increasing chain length and generally better performance in comparison to the (poly)methylene dimethacrylate cross-linkers of comparable size, however with less apparent effects of the chain lengths on the pore distribution. The monolithic columns prepared with tetraoxyethylene dimethacrylate (TeEDMA) showed the best efficiency of all the columns tested, corresponding to HETP=15 μm (approx. 70,000 theoretical plates/m), show excellent column-to-column reproducibility with standard deviations of 2.5% in retention times, good permeability and low mass transfer resistance, so that is suitable for fast separation of low-molecular compounds in 2 min or less. By modification of the fused-silica capillary inner walls pre-treatment procedure, very good long-term stability was achieved even in 0.5 mm i.d. capillary format. The TeEDMA column can be also used for size-exclusion chromatography of lower non-polar synthetic polymers, whereas it is less suitable for separations of proteins than the HEDMA column.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc13024039
- 003
- CZ-PrNML
- 005
- 20130703125409.0
- 007
- ta
- 008
- 130703s2013 ne f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1016/j.chroma.2012.12.003 $2 doi
- 035 __
- $a (PubMed)23273635
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a ne
- 100 1_
- $a Jandera, Pavel $u Department of Analytical Chemistry, Faculty of Chemical Technology, University of Pardubice, Studentská 573, 53210 Pardubice, Czech Republic. Pavel.Jandera@upce.cz
- 245 10
- $a Cross-linker effects on the separation efficiency on (poly)methacrylate capillary monolithic columns. Part I. Reversed-phase liquid chromatography / $c P. Jandera, M. Staňková, V. Škeříková, J. Urban,
- 520 9_
- $a We synthesized 8 polymethacrylate monolithic capillary columns using laurylmethacrylate functional monomer and various cross-linking monomers differing in the polarity and size. The efficiency of monolithic columns for low-molecular compounds significantly improved with increasing number of repeat non-polar methylene groups in the cross-linker molecules, correlating with greater proportion of small pores with size less than 50 nm. The best efficiency with HETP=25 μm for alkylbenzenes was achieved for columns prepared using hexamethylene dimethacrylate (HEDMA). Columns prepared with polar (poly)oxyethylene dimethacrylate cross-linkers show also improved efficiency with increasing chain length and generally better performance in comparison to the (poly)methylene dimethacrylate cross-linkers of comparable size, however with less apparent effects of the chain lengths on the pore distribution. The monolithic columns prepared with tetraoxyethylene dimethacrylate (TeEDMA) showed the best efficiency of all the columns tested, corresponding to HETP=15 μm (approx. 70,000 theoretical plates/m), show excellent column-to-column reproducibility with standard deviations of 2.5% in retention times, good permeability and low mass transfer resistance, so that is suitable for fast separation of low-molecular compounds in 2 min or less. By modification of the fused-silica capillary inner walls pre-treatment procedure, very good long-term stability was achieved even in 0.5 mm i.d. capillary format. The TeEDMA column can be also used for size-exclusion chromatography of lower non-polar synthetic polymers, whereas it is less suitable for separations of proteins than the HEDMA column.
- 650 _2
- $a zvířata $7 D000818
- 650 _2
- $a benzenové deriváty $x izolace a purifikace $7 D001555
- 650 _2
- $a skot $7 D002417
- 650 _2
- $a chromatografie s reverzní fází $x přístrojové vybavení $7 D056148
- 650 _2
- $a reagencia zkříženě vázaná $x chemie $7 D003432
- 650 _2
- $a polymerizace $7 D058105
- 650 _2
- $a kyseliny polymethakrylové $x chemie $7 D011109
- 650 _2
- $a poréznost $7 D016062
- 650 _2
- $a proteiny $x izolace a purifikace $7 D011506
- 650 _2
- $a reprodukovatelnost výsledků $7 D015203
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Staňková, Magda $u -
- 700 1_
- $a Škeříková, Veronika $u -
- 700 1_
- $a Urban, Jiří $u -
- 773 0_
- $w MED00004962 $t Journal of chromatography. A $x 1873-3778 $g Roč. 1274(2013), s. 97-106
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/23273635 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20130703 $b ABA008
- 991 __
- $a 20130703125827 $b ABA008
- 999 __
- $a ok $b bmc $g 987719 $s 822419
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2013 $b 1274 $d 97-106 $i 1873-3778 $m Journal of chromatography. A, Including electrophoresis and other separation methods $n J Chromatogr A $x MED00004962
- LZP __
- $a Pubmed-20130703