Echocardiographic changes after cardiac resynchronisation therapy

R. Praus, L. Haman, M. Tauchman, R. Pudil, V. Blaha, P. Parizek,

. 2012 ; 70 (12) : 1250-7.

Language English Country Poland

Document type Journal Article, Research Support, Non-U.S. Gov't

BACKGROUND AND AIM: The aim of this prospective study was to evaluate echocardiographic changes in clinical responders and nonresponders after 3 and 15 months of cardiac resynchronisation therapy (CRT). METHODS: Fifty eight patients in whom a biventricular system was implanted between 2005 and 2008 were followed up at 3 and at 15 months. Clinical and echocardiography parameters including intra- and interventricular dyssynchrony were assessed at baseline and after 3 and 15 months of CRT. Every patient in whom quality of life, New York Heart Association (NYHA) class and/or 6-minute walk test (6MWT) improved (improvement of ≥ 1 NYHA class, 6MWT by more than 10%), and who was neither in hospital for heart failure nor died for cardiac reasons, was categorised as a clinical responder. RESULTS: In the responders' group, we found a significant improvement of right ventricular systolic function and a decrease in the size of the right ventricle (RV) only after 15 months (tricuspid annular plane systolic excursion [TAPSE] 17.8 ± 4.0 mm to 19.4 ± 3.7 mm, p 〈 0.05, RV diameter 29.3 ± 5.0 mm to 27.8 ± 4.2 mm, p 〈 0.05). Significant improvement of other monitored parameters occurred 3 months after CRT implantation: left ventricle (LV) end-diastolic diameter 70.5 ± 7.8 mm to 66.1 ± 8.3 mm, p 〈 0.001, LV ejection fraction 22.0 ± 5.4% to 27.1 ± 9.8%, p 〈 0.05, pulmonary artery pressure (peak gradient of tricuspid regurgitation) 37.1 ± 14.8 mm Hg to 27.6 ± 8.9 mm Hg, p 〈 0.001, tricuspid regurgitation (grade) 1.9 ± 0.9 to 1.5 ± 0.6, p 〈 0.05, mitral regurgitation (grade) 2.6 ± 0.9 to 2.2 ± 0.9, p 〈 0.001, LV dP/dt max (peak positive rate of pressure rise [slope of mitral regurgitant jet]) 482.4 ± 155.4 mm Hg/s to 981.2 ± 654.5 mm Hg/s, p 〈 0.001, velocity time integral (VTI) in LV outflow tract (LVOT) 14.1 ± 4.3 cm to 16.7 ± 4.1 cm, p 〈 0.001. In the group of nonresponders, only 2 parameters improved significantly: LV dP/dt max 561.2 ± 347.9 mm Hg/s to 1024.5 ± 745.3 mm Hg/s, p 〈 0.001, and LVOT VTI 14.5 ± 3.0 cm to 16.3 ± 2.9 cm, p 〈 0.001. Other echocardiographic parameters did not show any important changes, and no changes occurred between 3 and 15 months. On the contrary, after 15 months we saw significant progression of tricuspid regurgitation in nonresponders. In multivariate analysis, combination of baseline delay between time to peak systolic velocity in ejection phase at basal septal and basal lateral segments (Ts-lateral-septal delay) and serum creatinine was a strong predictor of clinical CRT response (area under curve was 0.80, percentage of correct decision was 82%). CONCLUSIONS: In the group of responders, significant changes of most monitored echocardiographic parameters were observed 3 months after CRT implantation. The only parameters which changed significantly after 15 months, but not previously, were the systolic function of the RV and the decrease in the RV size. In the group of nonresponders, these changes were not observed.

000      
00000naa a2200000 a 4500
001      
bmc13024045
003      
CZ-PrNML
005      
20130710110814.0
007      
ta
008      
130703s2012 pl f 000 0|eng||
009      
AR
035    __
$a (PubMed)23264243
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a pl
100    1_
$a Praus, Rudolf $u Department of Cardiovascular Medicine, University Hospital, Hradec Kralove, Czech Republic. rudolfpraus@seznam.cz
245    10
$a Echocardiographic changes after cardiac resynchronisation therapy / $c R. Praus, L. Haman, M. Tauchman, R. Pudil, V. Blaha, P. Parizek,
520    9_
$a BACKGROUND AND AIM: The aim of this prospective study was to evaluate echocardiographic changes in clinical responders and nonresponders after 3 and 15 months of cardiac resynchronisation therapy (CRT). METHODS: Fifty eight patients in whom a biventricular system was implanted between 2005 and 2008 were followed up at 3 and at 15 months. Clinical and echocardiography parameters including intra- and interventricular dyssynchrony were assessed at baseline and after 3 and 15 months of CRT. Every patient in whom quality of life, New York Heart Association (NYHA) class and/or 6-minute walk test (6MWT) improved (improvement of ≥ 1 NYHA class, 6MWT by more than 10%), and who was neither in hospital for heart failure nor died for cardiac reasons, was categorised as a clinical responder. RESULTS: In the responders' group, we found a significant improvement of right ventricular systolic function and a decrease in the size of the right ventricle (RV) only after 15 months (tricuspid annular plane systolic excursion [TAPSE] 17.8 ± 4.0 mm to 19.4 ± 3.7 mm, p 〈 0.05, RV diameter 29.3 ± 5.0 mm to 27.8 ± 4.2 mm, p 〈 0.05). Significant improvement of other monitored parameters occurred 3 months after CRT implantation: left ventricle (LV) end-diastolic diameter 70.5 ± 7.8 mm to 66.1 ± 8.3 mm, p 〈 0.001, LV ejection fraction 22.0 ± 5.4% to 27.1 ± 9.8%, p 〈 0.05, pulmonary artery pressure (peak gradient of tricuspid regurgitation) 37.1 ± 14.8 mm Hg to 27.6 ± 8.9 mm Hg, p 〈 0.001, tricuspid regurgitation (grade) 1.9 ± 0.9 to 1.5 ± 0.6, p 〈 0.05, mitral regurgitation (grade) 2.6 ± 0.9 to 2.2 ± 0.9, p 〈 0.001, LV dP/dt max (peak positive rate of pressure rise [slope of mitral regurgitant jet]) 482.4 ± 155.4 mm Hg/s to 981.2 ± 654.5 mm Hg/s, p 〈 0.001, velocity time integral (VTI) in LV outflow tract (LVOT) 14.1 ± 4.3 cm to 16.7 ± 4.1 cm, p 〈 0.001. In the group of nonresponders, only 2 parameters improved significantly: LV dP/dt max 561.2 ± 347.9 mm Hg/s to 1024.5 ± 745.3 mm Hg/s, p 〈 0.001, and LVOT VTI 14.5 ± 3.0 cm to 16.3 ± 2.9 cm, p 〈 0.001. Other echocardiographic parameters did not show any important changes, and no changes occurred between 3 and 15 months. On the contrary, after 15 months we saw significant progression of tricuspid regurgitation in nonresponders. In multivariate analysis, combination of baseline delay between time to peak systolic velocity in ejection phase at basal septal and basal lateral segments (Ts-lateral-septal delay) and serum creatinine was a strong predictor of clinical CRT response (area under curve was 0.80, percentage of correct decision was 82%). CONCLUSIONS: In the group of responders, significant changes of most monitored echocardiographic parameters were observed 3 months after CRT implantation. The only parameters which changed significantly after 15 months, but not previously, were the systolic function of the RV and the decrease in the RV size. In the group of nonresponders, these changes were not observed.
650    _2
$a senioři $7 D000368
650    12
$a srdeční resynchronizační terapie $7 D058406
650    _2
$a koronární nemoc $x komplikace $x terapie $x ultrasonografie $7 D003327
650    12
$a echokardiografie $7 D004452
650    _2
$a zátěžový test $7 D005080
650    _2
$a ženské pohlaví $7 D005260
650    _2
$a následné studie $7 D005500
650    _2
$a srdeční komory $x ultrasonografie $7 D006352
650    _2
$a lidé $7 D006801
650    _2
$a mužské pohlaví $7 D008297
650    _2
$a kvalita života $7 D011788
650    _2
$a výsledek terapie $7 D016896
650    _2
$a trikuspidální insuficience $x etiologie $x prevence a kontrola $x ultrasonografie $7 D014262
650    _2
$a funkce pravé komory srdeční $7 D016278
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Haman, Ludek $u -
700    1_
$a Tauchman, Miloslav $u -
700    1_
$a Pudil, Radek $u -
700    1_
$a Blaha, Vaclav $u -
700    1_
$a Parizek, Petr $u -
773    0_
$w MED00003056 $t Kardiologia polska $x 0022-9032 $g Roč. 70, č. 12 (2012), s. 1250-7
856    41
$u https://pubmed.ncbi.nlm.nih.gov/23264243 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20130703 $b ABA008
991    __
$a 20130710111237 $b ABA008
999    __
$a ok $b bmc $g 987725 $s 822425
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2012 $b 70 $c 12 $d 1250-7 $i 0022-9032 $m Kardiologia Polska $n Kardiol Pol $x MED00003056
LZP    __
$a Pubmed-20130703

Find record

Citation metrics

Loading data ...

Archiving options

Loading data ...