The impact of left ventricle assist device on circulating endothelial microparticles - pilot study
J. Pitha, Z. Dorazilova, V. Melenovsky, I. Kralova Lesna, P. Stavek, J. Stepankova, M. Urban, J. Maly, I. Netuka,
Language English Country Sweden
Document type Clinical Trial, Journal Article, Research Support, Non-U.S. Gov't
PubMed
23183513
Knihovny.cz E-resources
- MeSH
- Biomarkers blood MeSH
- Endothelium, Vascular metabolism pathology MeSH
- Cardiomyopathy, Dilated blood surgery MeSH
- Adult MeSH
- Hemodynamics physiology MeSH
- Myocardial Ischemia blood surgery MeSH
- Middle Aged MeSH
- Humans MeSH
- Cell-Derived Microparticles metabolism pathology MeSH
- Pilot Projects MeSH
- Heart-Assist Devices adverse effects MeSH
- Prospective Studies MeSH
- Aged MeSH
- Heart Failure blood surgery MeSH
- Check Tag
- Adult MeSH
- Middle Aged MeSH
- Humans MeSH
- Male MeSH
- Aged MeSH
- Publication type
- Journal Article MeSH
- Clinical Trial MeSH
- Research Support, Non-U.S. Gov't MeSH
OBJECTIVES: Recent technological breakthroughs in the design of reliable systems for long term non-pulsatile mechanical heart support offer the possibility to study the effect of continuous blood flow in the vascular system. Generally, it is assumed that the absence of physiological pulsatile flow leads to prothrombogenic and proatherogenic changes. We investigated the change in the circulating endothelial microparticle concentration as a marker of endothelial damage in patients implanted with a continuous-flow left ventricle assist device (LVAD). METHODS: Endothelial microparticles were measured in 8 males (mean age 54.1±11.5 years) with terminal heart failure before and 3 months after implantation of an LVAD. The group consisted of 3 patients with dilated cardiomyopathy, 3 patients with ischemic cardiomyopathy, 1 patient with both conditions and 1 patient with congenital valvular disease. The concentration of endothelial microparticles was determined by ELISA Zymutest MP activity test. RESULTS: We did not observe a significant change in the concentration of circulating endothelial microparticles measured before and 3 months after implantation (p=0.669). High inter-individual variability in response to implantation was found. However, no association between a change in endothelial microparticle concentration and heart failure aetiology or a significant clinical complication attributed to LVAD implantation was observed. CONCLUSION: Results from this preliminary pilot study do not indicate that LVADs contribute to short-term vascular damage as defined by an increase in circulating endothelial microparticles.
- 000
- 00000naa a2200000 a 4500
- 001
- bmc13024108
- 003
- CZ-PrNML
- 005
- 20131002123541.0
- 007
- ta
- 008
- 130703s2012 sw f 000 0|eng||
- 009
- AR
- 035 __
- $a (PubMed)23183513
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a sw
- 100 1_
- $a Pitha, Jan $u Institute of Clinical and Experimental Medicine, Prague, Czech Republic. japi@ikem.cz
- 245 14
- $a The impact of left ventricle assist device on circulating endothelial microparticles - pilot study / $c J. Pitha, Z. Dorazilova, V. Melenovsky, I. Kralova Lesna, P. Stavek, J. Stepankova, M. Urban, J. Maly, I. Netuka,
- 520 9_
- $a OBJECTIVES: Recent technological breakthroughs in the design of reliable systems for long term non-pulsatile mechanical heart support offer the possibility to study the effect of continuous blood flow in the vascular system. Generally, it is assumed that the absence of physiological pulsatile flow leads to prothrombogenic and proatherogenic changes. We investigated the change in the circulating endothelial microparticle concentration as a marker of endothelial damage in patients implanted with a continuous-flow left ventricle assist device (LVAD). METHODS: Endothelial microparticles were measured in 8 males (mean age 54.1±11.5 years) with terminal heart failure before and 3 months after implantation of an LVAD. The group consisted of 3 patients with dilated cardiomyopathy, 3 patients with ischemic cardiomyopathy, 1 patient with both conditions and 1 patient with congenital valvular disease. The concentration of endothelial microparticles was determined by ELISA Zymutest MP activity test. RESULTS: We did not observe a significant change in the concentration of circulating endothelial microparticles measured before and 3 months after implantation (p=0.669). High inter-individual variability in response to implantation was found. However, no association between a change in endothelial microparticle concentration and heart failure aetiology or a significant clinical complication attributed to LVAD implantation was observed. CONCLUSION: Results from this preliminary pilot study do not indicate that LVADs contribute to short-term vascular damage as defined by an increase in circulating endothelial microparticles.
- 650 _2
- $a dospělí $7 D000328
- 650 _2
- $a senioři $7 D000368
- 650 _2
- $a biologické markery $x krev $7 D015415
- 650 _2
- $a dilatační kardiomyopatie $x krev $x chirurgie $7 D002311
- 650 _2
- $a mikropartikule $x metabolismus $x patologie $7 D055252
- 650 _2
- $a cévní endotel $x metabolismus $x patologie $7 D004730
- 650 _2
- $a srdeční selhání $x krev $x chirurgie $7 D006333
- 650 _2
- $a podpůrné srdeční systémy $x škodlivé účinky $7 D006353
- 650 _2
- $a hemodynamika $x fyziologie $7 D006439
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a mužské pohlaví $7 D008297
- 650 _2
- $a lidé středního věku $7 D008875
- 650 _2
- $a ischemická choroba srdeční $x krev $x chirurgie $7 D017202
- 650 _2
- $a pilotní projekty $7 D010865
- 650 _2
- $a prospektivní studie $7 D011446
- 655 _2
- $a klinické zkoušky $7 D016430
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Dorazilova, Zora $u -
- 700 1_
- $a Melenovsky, Vojtech $u -
- 700 1_
- $a Kralova Lesna, Ivana $u -
- 700 1_
- $a Stavek, Petr $u -
- 700 1_
- $a Stepankova, Jitka $u -
- 700 1_
- $a Urban, Marian $u -
- 700 1_
- $a Maly, Jiri $u -
- 700 1_
- $a Netuka, Ivan $u -
- 773 0_
- $w MED00168352 $t Neuro endocrinology letters $x 0172-780X $g Roč. 33 Suppl 2(2012), s. 68-72
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/23183513 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20130703 $b ABA008
- 991 __
- $a 20131002124058 $b ABA008
- 999 __
- $a ok $b bmc $g 987788 $s 822488
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2012 $b 33 Suppl 2 $d 68-72 $i 0172-780X $m Neuro-endocrinology letters $n Neuro-endocrinol. lett. $x MED00168352
- LZP __
- $a Pubmed-20130703