Chromatography and spectrofluorometry of brain fluorophores in neuronal ceroid lipofuscinosis (NCL)

D Armstrong, J Wilhelm, F Smid, M Elleder

. 1992 ; 64 (3) : 293-302.

Jazyk angličtina Země Švýcarsko

Typ dokumentu práce podpořená grantem

Perzistentní odkaz   https://www.medvik.cz/link/bmc13029427

Grantová podpora
PL226 MZ0 CEP - Centrální evidence projektů

The aim of the present work was to develop a chromatographic system for the separation of individual fluorophores extracted from neuronal ceroid lipofuscinosis (NCL) brain and isolated storage bodies. Extracts from gray matter were best resolved on silica-gel HPTLC plates using a mixture of chloroform/methanol/water (55:45:10 by vol.). Two other chromatographic systems were tested which gave poorer separation. Corrected fluorescence spectra were obtained on the original extract and fluorescence intensity, especially at longer wavelengths was increased in both samples. Yellow and blue fluorophores were detected on HPTLC plates using a primary violet and secondary yellow filter with cut-off levels of 400 and 520 nm, respectively. Plates were photographed at 20 min, 2 h and 1 week after chromatography. With this filter system, up to 12 yellow bands of differing intensity were observed at 20 min but with time, some of these changed to blue as a result of autoxidation. NCL tissues emit yellow fluorescence when viewed under light microscopy, however extracted material did not demonstrate a distinct peak in this region of the spectrum which should be around 575 nm. HPTLC confirmed this observation and time studies revealed that autoxidation changes occur and must be carefully controlled to reduce artifacts. The discrepancy between extracted and non-extracted observations may be the result of superposition of multiple fluorophores with differing maxima and/or a self-absorption phenomenon. The combination of chromatographic separation and spectral analysis as described in this study, may be a valuable technique to further clarify the characteristics of compound fluorescent lipopigments. It is suggested that NCL fluorophores of human brain differ in their properties from other models.

000      
00000naa a2200000 a 4500
001      
bmc13029427
003      
CZ-PrNML
005      
20130916101851.0
007      
ta
008      
130913s1992 sz f 000 0|eng||
009      
AR
035    __
$a (PubMed)1405786
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a sz
100    1_
$a Armstrong, Donald $u Department of Medical Technology, State University of New York, Buffalo 14215. $7 gn_A_00008622
245    10
$a Chromatography and spectrofluorometry of brain fluorophores in neuronal ceroid lipofuscinosis (NCL) / $c D Armstrong, J Wilhelm, F Smid, M Elleder
520    9_
$a The aim of the present work was to develop a chromatographic system for the separation of individual fluorophores extracted from neuronal ceroid lipofuscinosis (NCL) brain and isolated storage bodies. Extracts from gray matter were best resolved on silica-gel HPTLC plates using a mixture of chloroform/methanol/water (55:45:10 by vol.). Two other chromatographic systems were tested which gave poorer separation. Corrected fluorescence spectra were obtained on the original extract and fluorescence intensity, especially at longer wavelengths was increased in both samples. Yellow and blue fluorophores were detected on HPTLC plates using a primary violet and secondary yellow filter with cut-off levels of 400 and 520 nm, respectively. Plates were photographed at 20 min, 2 h and 1 week after chromatography. With this filter system, up to 12 yellow bands of differing intensity were observed at 20 min but with time, some of these changed to blue as a result of autoxidation. NCL tissues emit yellow fluorescence when viewed under light microscopy, however extracted material did not demonstrate a distinct peak in this region of the spectrum which should be around 575 nm. HPTLC confirmed this observation and time studies revealed that autoxidation changes occur and must be carefully controlled to reduce artifacts. The discrepancy between extracted and non-extracted observations may be the result of superposition of multiple fluorophores with differing maxima and/or a self-absorption phenomenon. The combination of chromatographic separation and spectral analysis as described in this study, may be a valuable technique to further clarify the characteristics of compound fluorescent lipopigments. It is suggested that NCL fluorophores of human brain differ in their properties from other models.
590    __
$a bohemika - dle Pubmed
650    12
$a mozek - chemie $7 D001923
650    02
$a ceroid $x izolace a purifikace $7 D002566
650    02
$a chromatografie na tenké vrstvě $x metody $7 D002855
650    12
$a fluorescenční barviva $x izolace a purifikace $7 D005456
650    02
$a lidé $7 D006801
650    12
$a lipidy $x izolace a purifikace $7 D008055
650    12
$a neuronální ceroidlipofuscinózy $x metabolismus $7 D009472
650    02
$a oxidace-redukce $7 D010084
650    02
$a fluorescenční spektrometrie $7 D013050
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Wilhelm, Jiří, $d 1950- $7 nlk19990074059 $u Department of Medical Technology, State University of New York, Buffalo 14215; Laboratory for Endocrinology and Metabolism, Charles University, School of Medicine, Prague, Czechoslovakia
700    1_
$a Šmíd, František, $d 1940- $7 jo20010088859 $u Institute of Pathology, Charles University, School of Medicine, Prague, Czechoslovakia
700    1_
$a Elleder, Milan, $d 1938-2011 $7 jn20000400630 $u Institute of Pathology, Charles University, School of Medicine, Prague, Czechoslovakia
773    0_
$t Mechanisms of ageing and development $x 0047-6374 $g Roč. 64, č. 3 (1992), s. 293-302 $p Mech Ageing Dev $w MED00003321
910    __
$a ABA008 $y 3 $z 0
990    __
$a 20130913094815 $b ABA008
991    __
$a 20130916102352 $b ABA008
999    __
$a ok $b bmc $g 993496 $s 827864
BAS    __
$a 3
BMC    __
$x MED00003321 $i 0047-6374 $a 1992 $b 64 $c 3 $d 293-302 $m Mechanisms of ageing and development $n Mech Ageing Dev
GRA    __
$a PL226 $p MZ0
LZP    __
$a NLK 201309/lpbo

Najít záznam

Citační ukazatele

Pouze přihlášení uživatelé

Možnosti archivace

Nahrávání dat ...