• Je něco špatně v tomto záznamu ?

Challenges in the development of bioanalytical liquid chromatography-mass spectrometry method with emphasis on fast analysis

L. Nováková,

Jazyk angličtina Země Nizozemsko

Typ dokumentu časopisecké články, práce podpořená grantem, přehledy

Perzistentní odkaz   https://www.medvik.cz/link/bmc13031865

The development of bioanalytical methods has become more and more challenging over the past years due to very demanding requirements in terms of method reliability, sensitivity, speed of analysis and sample throughput. LC-MS/MS has established itself as a method of choice for routine analysis of biological materials. A development of such method consists of several steps including sample preparation and clean-up step, efficient chromatographic separation, sensitive and selective detection of analytes in complex matrices, a choice of convenient data processing and calibration approach and finally method validation. Each of these steps has its own constraints and challenges, which are discussed in detail in this review. Novel and modern approaches in sample preparation, chromatography and detection are especially emphasized. Attention is paid to proper calibration approach and matrix effects that can seriously affect method accuracy and precision.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc13031865
003      
CZ-PrNML
005      
20131007122303.0
007      
ta
008      
131002s2013 ne f 000 0|eng||
009      
AR
024    7_
$a 10.1016/j.chroma.2012.08.087 $2 doi
035    __
$a (PubMed)22999195
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a ne
100    1_
$a Nováková, Lucie $u Department of Analytical Chemistry, Faculty of Pharmacy, Charles University, Heyrovského 1203, 500 05 Hradec Králové, Czech Republic. nol@email.cz
245    10
$a Challenges in the development of bioanalytical liquid chromatography-mass spectrometry method with emphasis on fast analysis / $c L. Nováková,
520    9_
$a The development of bioanalytical methods has become more and more challenging over the past years due to very demanding requirements in terms of method reliability, sensitivity, speed of analysis and sample throughput. LC-MS/MS has established itself as a method of choice for routine analysis of biological materials. A development of such method consists of several steps including sample preparation and clean-up step, efficient chromatographic separation, sensitive and selective detection of analytes in complex matrices, a choice of convenient data processing and calibration approach and finally method validation. Each of these steps has its own constraints and challenges, which are discussed in detail in this review. Novel and modern approaches in sample preparation, chromatography and detection are especially emphasized. Attention is paid to proper calibration approach and matrix effects that can seriously affect method accuracy and precision.
650    _2
$a zvířata $7 D000818
650    _2
$a chromatografie kapalinová $x ekonomika $x přístrojové vybavení $x metody $7 D002853
650    _2
$a lidé $7 D006801
650    _2
$a hmotnostní spektrometrie $x ekonomika $x přístrojové vybavení $x metody $7 D013058
650    _2
$a časové faktory $7 D013997
650    _2
$a validační studie jako téma $7 D054928
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
655    _2
$a přehledy $7 D016454
773    0_
$w MED00004962 $t Journal of chromatography. A $x 1873-3778 $g Roč. 1292(2013), s. 25-37
856    41
$u https://pubmed.ncbi.nlm.nih.gov/22999195 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20131002 $b ABA008
991    __
$a 20131007122824 $b ABA008
999    __
$a ok $b bmc $g 995952 $s 830310
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2013 $b 1292 $d 25-37 $i 1873-3778 $m Journal of chromatography. A, Including electrophoresis and other separation methods $n J Chromatogr A $x MED00004962
LZP    __
$a Pubmed-20131002

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...