• Je něco špatně v tomto záznamu ?

Intra-day and inter-day reliability of heart rate variability measurement

L. Cipryan, M. Litschmannova,

. 2013 ; 31 (2) : 150-8.

Jazyk angličtina Země Anglie, Velká Británie

Typ dokumentu srovnávací studie, časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc13031876

At present, analysis of heart rate variability (HRV) is becoming widely used as a clinical or research tool. Supported reliability studies for HRV measurement are, however, still limited. The main purpose was to perform an assessment of the absolute and relative reliability of HRV parameters from short-term recordings by means of orthoclinostatic stimulation and to investigate, whether there is a difference in repeating the retest immediately or after several days. The study group consisted of 99 participants (mean age 22 ± 1.24 years). Standard HRV indexes were computed: PT (total spectral power), PHF (high frequency spectral power), PLF (low frequency spectral power) and LF/HF. Absolute reliability was assessed by the standard error of measurement and 95% limits of agreement; relative reliability was assessed by the intraclass correlation coefficient. There was also an estimate of the sample size needed to detect the mean difference ≥ 30% of the between-subject standard deviation. In conclusion, a large random variation (within individuals) of HRV parameters was revealed, regardless of whether the retest was repeated immediately or with an interruption. For most HRV parameters (particularly in the immediately repeated test-retest), however, random variation represents a limited portion of the between-subject variability.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc13031876
003      
CZ-PrNML
005      
20131007125042.0
007      
ta
008      
131002s2013 enk f 000 0|eng||
009      
AR
024    7_
$a 10.1080/02640414.2012.721931 $2 doi
035    __
$a (PubMed)22963409
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a enk
100    1_
$a Cipryan, Lukas $u Centre for Diagnostics of Human Movement, Ostrava University, Ostrava, Czech Republic. lukas.cipryan@osu.cz
245    10
$a Intra-day and inter-day reliability of heart rate variability measurement / $c L. Cipryan, M. Litschmannova,
520    9_
$a At present, analysis of heart rate variability (HRV) is becoming widely used as a clinical or research tool. Supported reliability studies for HRV measurement are, however, still limited. The main purpose was to perform an assessment of the absolute and relative reliability of HRV parameters from short-term recordings by means of orthoclinostatic stimulation and to investigate, whether there is a difference in repeating the retest immediately or after several days. The study group consisted of 99 participants (mean age 22 ± 1.24 years). Standard HRV indexes were computed: PT (total spectral power), PHF (high frequency spectral power), PLF (low frequency spectral power) and LF/HF. Absolute reliability was assessed by the standard error of measurement and 95% limits of agreement; relative reliability was assessed by the intraclass correlation coefficient. There was also an estimate of the sample size needed to detect the mean difference ≥ 30% of the between-subject standard deviation. In conclusion, a large random variation (within individuals) of HRV parameters was revealed, regardless of whether the retest was repeated immediately or with an interruption. For most HRV parameters (particularly in the immediately repeated test-retest), however, random variation represents a limited portion of the between-subject variability.
650    _2
$a analýza rozptylu $7 D000704
650    12
$a cirkadiánní rytmus $7 D002940
650    _2
$a elektrokardiografie $7 D004562
650    _2
$a ženské pohlaví $7 D005260
650    _2
$a srdeční frekvence $x fyziologie $7 D006339
650    _2
$a lidé $7 D006801
650    _2
$a mužské pohlaví $7 D008297
650    _2
$a postura těla $x fyziologie $7 D011187
650    _2
$a referenční hodnoty $7 D012016
650    _2
$a reprodukovatelnost výsledků $7 D015203
650    _2
$a velikost vzorku $7 D018401
650    _2
$a mladý dospělý $7 D055815
655    _2
$a srovnávací studie $7 D003160
655    _2
$a časopisecké články $7 D016428
700    1_
$a Litschmannova, Martina $u -
773    0_
$w MED00002949 $t Journal of sports sciences $x 1466-447X $g Roč. 31, č. 2 (2013), s. 150-8
856    41
$u https://pubmed.ncbi.nlm.nih.gov/22963409 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20131002 $b ABA008
991    __
$a 20131007125603 $b ABA008
999    __
$a ok $b bmc $g 995963 $s 830321
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2013 $b 31 $c 2 $d 150-8 $i 1466-447X $m Journal of sports sciences $n J Sports Sci $x MED00002949
LZP    __
$a Pubmed-20131002

Najít záznam

Citační ukazatele

Pouze přihlášení uživatelé

Možnosti archivace

Nahrávání dat ...