Detail
Article
Online article
FT
Medvik - BMC
  • Something wrong with this record ?

Catheter ablation of focal atrial tachycardia from the aortic cusp: the role of electroanatomic mapping and intracardiac echocardiography

H. Mlčochová, D. Wichterle, P. Peichl, J. Kautzner,

. 2013 ; 36 (1) : e19-22.

Language English Country United States

Document type Case Reports, Journal Article, Research Support, Non-U.S. Gov't

Catheter ablation of periatrioventricular (peri-AV) nodal atrial tachycardias (AT) from the noncoronary aortic cusp (NCC) can be challenging due to the close proximity of the AV node In such cases, intracardiac echocardiography (ICE) together with three-dimensional mapping system can be helpful in guiding the ablation catheter and in assessing the anatomic relationship of the aorta to the surrounding structures. We report two patients with AT originating near the AV node who underwent successful catheter ablation from the NCC. ICE proved useful in positioning the ablation catheter within the aortic cusps. Electroanatomic mapping enabled tagging the earliest activation site and renavigation back.

References provided by Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc13031957
003      
CZ-PrNML
005      
20181023140302.0
007      
ta
008      
131002s2013 xxu f 000 0|eng||
009      
AR
024    7_
$a 10.1111/j.1540-8159.2010.02982.x $2 doi
035    __
$a (PubMed)21138448
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xxu
100    1_
$a Mlčochová, Hanka $u Department of Cardiology, Institute for Clinical and Experimental Medicine, Prague, Czech Republic.
245    10
$a Catheter ablation of focal atrial tachycardia from the aortic cusp: the role of electroanatomic mapping and intracardiac echocardiography / $c H. Mlčochová, D. Wichterle, P. Peichl, J. Kautzner,
520    9_
$a Catheter ablation of periatrioventricular (peri-AV) nodal atrial tachycardias (AT) from the noncoronary aortic cusp (NCC) can be challenging due to the close proximity of the AV node In such cases, intracardiac echocardiography (ICE) together with three-dimensional mapping system can be helpful in guiding the ablation catheter and in assessing the anatomic relationship of the aorta to the surrounding structures. We report two patients with AT originating near the AV node who underwent successful catheter ablation from the NCC. ICE proved useful in positioning the ablation catheter within the aortic cusps. Electroanatomic mapping enabled tagging the earliest activation site and renavigation back.
650    _2
$a dospělí $7 D000328
650    _2
$a aorta $x chirurgie $7 D001011
650    _2
$a fibrilace síní $x diagnóza $x chirurgie $7 D001281
650    _2
$a mapování potenciálů tělesného povrchu $x metody $7 D018780
650    _2
$a katetrizační ablace $x metody $7 D017115
650    _2
$a endosonografie $x metody $7 D019160
650    _2
$a ženské pohlaví $7 D005260
650    _2
$a lidé $7 D006801
650    _2
$a zobrazování trojrozměrné $x metody $7 D021621
650    _2
$a lidé středního věku $7 D008875
650    _2
$a chirurgie s pomocí počítače $x metody $7 D025321
650    _2
$a výsledek terapie $7 D016896
655    _2
$a kazuistiky $7 D002363
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Wichterle, Dan $u -
700    1_
$a Peichl, Petr, $u - $d 1976- $7 xx0092197
700    1_
$a Kautzner, Josef $u -
773    0_
$w MED00003671 $t Pacing and clinical electrophysiology PACE $x 1540-8159 $g Roč. 36, č. 1 (2013), s. e19-22
856    41
$u https://pubmed.ncbi.nlm.nih.gov/21138448 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20131002 $b ABA008
991    __
$a 20181023140809 $b ABA008
999    __
$a ok $b bmc $g 996044 $s 830402
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2013 $b 36 $c 1 $d e19-22 $i 1540-8159 $m Pacing and clinical electrophysiology $n Pacing Clin Electrophysiol $x MED00003671
LZP    __
$a Pubmed-20131002

Find record

Citation metrics

Loading data ...

Archiving options

Loading data ...