Detail
Článek
Článek online
FT
Medvik - BMČ
  • Je něco špatně v tomto záznamu ?

An image based microtiter plate reader system for 96-well format fluorescence assays [Bild-basierte Mikrotiterplattenleser System für 96-well Format Flureszenz Assay] [Un système de lecteur de microplaque basé sur une image pour épreuves de fluorescence de format de 96 puits]

Durai Arun P., Sankaran K., Muttan S.

. 2013 ; 9 (2) : 58-68.

Jazyk angličtina Země Česko Médium elektronický zdroj

Typ dokumentu práce podpořená grantem

Perzistentní odkaz   https://www.medvik.cz/link/bmc14040322

Background: 96-well microtiter plate assay are becoming popular analytical procedures in laboratory and clinical practices generating a demand for microtiter plate readers. The present colorimetric and fluorimetric based microtiter plate reader are efficient in general applications such as measuring reflectance, absorbance, and optical density of reaction mixtures. However, a dedicated system incorporating automation and computational techniques in specific microtiter plate readers for Drug discovery and Microbial viability, provides portability and compatibility with highthroughput analysis at affordable cost. Objective: To develop image-based reader system for semi-quantitative measurements of transport assay performed in microtiter plate. In this work, we focus on deduction of illumination source and classification of fluorescence emitted by transport assay using this microtiter plate reader. Method: We have taken the images of 96-well fluorescence efflux assay and developed an appropriate image analysis system to read the individual well images and categorize the results as fast efflux and slow efflux by the classifier. The images exhibited non-uniform illumination due to UV transilluminator, which then replaced by the circuit of blue LED after performing a study on its classification performance. Statistical descriptive features extracted from the image are classified using k-means clustering technique. The proposed system can be adapted to read any kind of microtiter plate assay. Results: For uniform illumination of the source, of both UV transilluminator and blue LED, the color profile varied in accord to reaction mixture concentration. For classification performance of the source, out of four different images at various intensities of illumination from blue LED circuit controlled by potentiometer, the classification of efflux assay for image with maximum intensity gave high accuracy than the rest. For classification performance of the classifier, out of 1920-sub-images, the classifier misclassifies none. Conclusion: For the microtiter plate reader, which classifies the liquid transport assay as fast efflux or slow efflux, the usage of UV transilluminator as illumination source is limited due to its non-uniform illumination and blue LED is apt for this application due its uniformity. The k-means clustering technique had been effective for this application when fed with statistical features describing the clusters.

Bild-basierte Mikrotiterplattenleser System für 96-well Format Flureszenz Assay

Un système de lecteur de microplaque basé sur une image pour épreuves de fluorescence de format de 96 puits

An image based microtiter plate reader system for 96-well format fluorescence assays [elektronický zdroj] /

Citace poskytuje Crossref.org

Bibliografie atd.

Literatura

000      
00000naa a2200000 a 4500
001      
bmc14040322
003      
CZ-PrNML
005      
20161031130345.0
007      
cr|cn|
008      
140106s2013 xr ad fs 000 0eng||
009      
eAR
024    7_
$a 10.24105/ejbi.2013.09.2.9 $2 doi
040    __
$a ABA008 $d ABA008 $e AACR2 $b cze
041    0_
$a eng $b ger $b fre
044    __
$a xr
100    1_
$a Durai Arun, P. $u Dept. Of Electronics and Communication Engineering, College of Engineering, Anna University, Chennai
245    13
$a An image based microtiter plate reader system for 96-well format fluorescence assays $h [elektronický zdroj] / $c Durai Arun P., Sankaran K., Muttan S.
246    31
$a Bild-basierte Mikrotiterplattenleser System für 96-well Format Flureszenz Assay
246    31
$a Un système de lecteur de microplaque basé sur une image pour épreuves de fluorescence de format de 96 puits
504    __
$a Literatura
520    9_
$a Background: 96-well microtiter plate assay are becoming popular analytical procedures in laboratory and clinical practices generating a demand for microtiter plate readers. The present colorimetric and fluorimetric based microtiter plate reader are efficient in general applications such as measuring reflectance, absorbance, and optical density of reaction mixtures. However, a dedicated system incorporating automation and computational techniques in specific microtiter plate readers for Drug discovery and Microbial viability, provides portability and compatibility with highthroughput analysis at affordable cost. Objective: To develop image-based reader system for semi-quantitative measurements of transport assay performed in microtiter plate. In this work, we focus on deduction of illumination source and classification of fluorescence emitted by transport assay using this microtiter plate reader. Method: We have taken the images of 96-well fluorescence efflux assay and developed an appropriate image analysis system to read the individual well images and categorize the results as fast efflux and slow efflux by the classifier. The images exhibited non-uniform illumination due to UV transilluminator, which then replaced by the circuit of blue LED after performing a study on its classification performance. Statistical descriptive features extracted from the image are classified using k-means clustering technique. The proposed system can be adapted to read any kind of microtiter plate assay. Results: For uniform illumination of the source, of both UV transilluminator and blue LED, the color profile varied in accord to reaction mixture concentration. For classification performance of the source, out of four different images at various intensities of illumination from blue LED circuit controlled by potentiometer, the classification of efflux assay for image with maximum intensity gave high accuracy than the rest. For classification performance of the classifier, out of 1920-sub-images, the classifier misclassifies none. Conclusion: For the microtiter plate reader, which classifies the liquid transport assay as fast efflux or slow efflux, the usage of UV transilluminator as illumination source is limited due to its non-uniform illumination and blue LED is apt for this application due its uniformity. The k-means clustering technique had been effective for this application when fed with statistical features describing the clusters.
650    12
$a fluorescence $7 D005453
650    12
$a titrace $x metody $x statistika a číselné údaje $7 D017186
650    12
$a optické jevy $7 D055620
650    _2
$a počítače $x využití $7 D003201
650    _2
$a osvětlení $7 D008029
650    12
$a klinické laboratorní techniky $x metody $x statistika a číselné údaje $7 D019411
650    _2
$a statistika jako téma $7 D013223
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Sankaran, K. $u Centre for Biotechnology, Alagappa College of Technology, Anna University, Chennai
700    1_
$a Muttan, S. $u Dept. Of Electronics and Communication Engineering, College of Engineering, Anna University, Chennai
773    0_
$t European journal for biomedical informatics $x 1801-5603 $g Roč. 9, č. 2 (2013), s. 58-68 $w MED00173462
856    41
$u http://www.ejbi.org/img/ejbi/2013/2/Durai_en.pdf $y plný text volně přístupný
910    __
$a ABA008 $z 0 $y 4
990    __
$a 20140105160254 $b ABA008
991    __
$a 20161031130309 $b ABA008
999    __
$a ok $b bmc $g 1004729 $s 838827
BAS    __
$a 3 $a 4
BMC    __
$a 2013 $b 9 $c 2 $d 58-68 $i 1801-5603 $m European Journal for Biomedical Informatics $n Eur. J. Biomed. Inform. (Praha) $x MED00173462
LZP    __
$c NLK185 $d 20140206 $a NLK 2014-03/vt

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...