• Je něco špatně v tomto záznamu ?

Analysis of wax esters by silver-ion high-performance liquid chromatography-tandem mass spectrometry

V. Vrkoslav, K. Urbanová, M. Háková, J. Cvačka,

Jazyk angličtina Země Nizozemsko

Typ dokumentu časopisecké články, práce podpořená grantem

Perzistentní odkaz   https://www.medvik.cz/link/bmc14040675

Wax esters (WEs), esters of long-chain fatty acids and long-chain alcohols, were analysed by Ag-HPLC/APCI-MS/MS. Two ChromSpher Lipids columns connected in series (a total length of 50cm) and hexane-2-propanol-acetonitrile mobile phases were used to achieve good separation of the molecular species. The chromatographic behaviour of WEs was studied under optimised conditions: retention increased with the number of double bonds and with the temperature (15-35°C); retention times were affected by the double-bond position, trans isomers eluted earlier than cis isomers, and the WEs were partially separated depending on the aliphatic-chain length. The WEs provided simple APCI spectra with [M+H](+) ions, the MS/MS spectra showed fragments, which allowed their identification. The method was applied for an analysis of the WE mixtures from jojoba oil and human hair and the results were compared with analogous data from an optimised RP-HPLC system.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc14040675
003      
CZ-PrNML
005      
20140113112116.0
007      
ta
008      
140107s2013 ne f 000 0|eng||
009      
AR
024    7_
$a 10.1016/j.chroma.2013.06.031 $2 doi
035    __
$a (PubMed)23831001
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a ne
100    1_
$a Vrkoslav, Vladimír
245    10
$a Analysis of wax esters by silver-ion high-performance liquid chromatography-tandem mass spectrometry / $c V. Vrkoslav, K. Urbanová, M. Háková, J. Cvačka,
520    9_
$a Wax esters (WEs), esters of long-chain fatty acids and long-chain alcohols, were analysed by Ag-HPLC/APCI-MS/MS. Two ChromSpher Lipids columns connected in series (a total length of 50cm) and hexane-2-propanol-acetonitrile mobile phases were used to achieve good separation of the molecular species. The chromatographic behaviour of WEs was studied under optimised conditions: retention increased with the number of double bonds and with the temperature (15-35°C); retention times were affected by the double-bond position, trans isomers eluted earlier than cis isomers, and the WEs were partially separated depending on the aliphatic-chain length. The WEs provided simple APCI spectra with [M+H](+) ions, the MS/MS spectra showed fragments, which allowed their identification. The method was applied for an analysis of the WE mixtures from jojoba oil and human hair and the results were compared with analogous data from an optimised RP-HPLC system.
650    _2
$a vysokoúčinná kapalinová chromatografie $x metody $7 D002851
650    _2
$a estery $x analýza $7 D004952
650    _2
$a lidé $7 D006801
650    _2
$a stříbro $x chemie $7 D012834
650    _2
$a tandemová hmotnostní spektrometrie $x metody $7 D053719
650    _2
$a vosky $x analýza $7 D014885
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Urbanová, Klára $u -
700    1_
$a Háková, Matina $u -
700    1_
$a Cvačka, Josef $u -
773    0_
$w MED00004962 $t Journal of chromatography. A $x 1873-3778 $g Roč. 1302, č. - (2013), s. 105-10
856    41
$u https://pubmed.ncbi.nlm.nih.gov/23831001 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20140107 $b ABA008
991    __
$a 20140113112820 $b ABA008
999    __
$a ok $b bmc $g 1005071 $s 839187
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2013 $b 1302 $c - $d 105-10 $i 1873-3778 $m Journal of chromatography. A, Including electrophoresis and other separation methods $n J Chromatogr A $x MED00004962
LZP    __
$a Pubmed-20140107

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...