Je něco špatně v tomto záznamu ?
New solution IEF device for micropreparative separation of peptides and proteins
F. Duša, K. Šlais,
Jazyk angličtina Země Německo
Typ dokumentu časopisecké články, práce podpořená grantem
PubMed
23417644
DOI
10.1002/elps.201200485
Knihovny.cz E-zdroje
- MeSH
- design vybavení MeSH
- isoelektrická fokusace přístrojové vybavení metody MeSH
- mléčné bílkoviny izolace a purifikace MeSH
- peptidy izolace a purifikace MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
The article presents a new concept of preparative solution IEF where time requirements and efficiency are similar to gel-based IEF whereas simple fraction handling as well as quick and complete protein recovery typical for solution-based IEF methods are maintained. The presented method is based on the IEF in separation medium soaked in a segmented strip of nonwoven fabric. The strip is positioned in an open horizontal V-shaped trough. Suggested focusing method combines free solution IEF under continuous evaporation and whole channel dispensing. Separation medium based on ethylene glycol/water mixture enhances viscosity enough to reduce electroosmosis and prevents the medium from completely drying out. Generation of pH gradient and final local pH is visually traced by colored low-molecular pI markers added to input mixture, which enables an optimization of focusing process and collection of individual fractions at desired pH range. The proposed method was tested by fractionation of the proteins and bioactive peptides originating from raw whey. Moreover, subsequent HPLC analysis of the individually collected solution IEF fractions was used for identification of whey components. We confirmed that the method is capable to process directly few tenths of milliliters of raw samples including the salty ones.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc14040926
- 003
- CZ-PrNML
- 005
- 20140110114805.0
- 007
- ta
- 008
- 140107s2013 gw f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1002/elps.201200485 $2 doi
- 035 __
- $a (PubMed)23417644
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a gw
- 100 1_
- $a Duša, Filip
- 245 10
- $a New solution IEF device for micropreparative separation of peptides and proteins / $c F. Duša, K. Šlais,
- 520 9_
- $a The article presents a new concept of preparative solution IEF where time requirements and efficiency are similar to gel-based IEF whereas simple fraction handling as well as quick and complete protein recovery typical for solution-based IEF methods are maintained. The presented method is based on the IEF in separation medium soaked in a segmented strip of nonwoven fabric. The strip is positioned in an open horizontal V-shaped trough. Suggested focusing method combines free solution IEF under continuous evaporation and whole channel dispensing. Separation medium based on ethylene glycol/water mixture enhances viscosity enough to reduce electroosmosis and prevents the medium from completely drying out. Generation of pH gradient and final local pH is visually traced by colored low-molecular pI markers added to input mixture, which enables an optimization of focusing process and collection of individual fractions at desired pH range. The proposed method was tested by fractionation of the proteins and bioactive peptides originating from raw whey. Moreover, subsequent HPLC analysis of the individually collected solution IEF fractions was used for identification of whey components. We confirmed that the method is capable to process directly few tenths of milliliters of raw samples including the salty ones.
- 650 _2
- $a design vybavení $7 D004867
- 650 _2
- $a isoelektrická fokusace $x přístrojové vybavení $x metody $7 D007525
- 650 _2
- $a mléčné bílkoviny $x izolace a purifikace $7 D008894
- 650 _2
- $a peptidy $x izolace a purifikace $7 D010455
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Šlais, Karel $u -
- 773 0_
- $w MED00001508 $t Electrophoresis $x 1522-2683 $g Roč. 34, č. 11 (2013), s. 1519-25
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/23417644 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20140107 $b ABA008
- 991 __
- $a 20140110115506 $b ABA008
- 999 __
- $a ok $b bmc $g 1005322 $s 839438
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2013 $b 34 $c 11 $d 1519-25 $i 1522-2683 $m Electrophoresis $n Electrophoresis $x MED00001508
- LZP __
- $a Pubmed-20140107