-
Je něco špatně v tomto záznamu ?
Corrosion behavior of palladium-silver-copper alloys in model saliva
L Joska, M Poddana, J Leitner
Jazyk angličtina Země Anglie, Velká Británie
Typ dokumentu srovnávací studie, práce podpořená grantem
Grantová podpora
NR9124
MZ0
CEP - Centrální evidence projektů
- MeSH
- časové faktory MeSH
- elektrochemie MeSH
- koroze MeSH
- lidé MeSH
- měď * chemie MeSH
- mikroanalýza elektronovou sondou MeSH
- náhrada slin * chemie MeSH
- palladium * chemie MeSH
- potenciometrie MeSH
- povrchové vlastnosti MeSH
- stříbro * chemie MeSH
- termodynamika MeSH
- testování materiálů MeSH
- zubní slitiny * chemie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- práce podpořená grantem MeSH
- srovnávací studie MeSH
OBJECTIVES: Palladium-silver system alloyed with other metals represents one of possible material choices in prosthetics. Its corrosion properties are influenced by minority components added in order to obtain the properties required for stomatological purposes. The objective of this work was to ascertain the influence of copper on the corrosion mechanism of palladium-silver alloys. METHODS: Corrosion properties of four palladium-silver-copper alloys were compared with the behavior of the palladium-silver binary system. Standard electrochemical measurements in a model saliva solution were complemented with an XPS analysis of the specimens surface. Experimental data were compared with the results of thermodynamic analysis. RESULTS: The foregoing study revealed formation of a saline layer of insoluble silver compounds as the dominant feature of the corrosion mechanism in a binary system. This process is suppressed in ternary alloys where electrochemical reactions of copper take place on the alloy-electrolyte phase boundary leading to the formation of a layer based on copper oxides. SIGNIFICANCE: The alloying of the palladium-silver binary system with copper results in an important change in the corrosion behavior of ternary alloys. A change in the mechanism of interaction with the environment leads to susceptibility to non-uniform corrosion.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc14047368
- 003
- CZ-PrNML
- 005
- 20190104125604.0
- 007
- ta
- 008
- 140225s2008 enkd f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1016/j.dental.2007.11.017 $2 doi
- 035 __
- $a (PubMed)18191189
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a enk
- 100 1_
- $a Joska, Luděk $7 xx0103993 $u Institute of Chemical Technology, Department of Metals and Corrosion Engineering, Technicka 5, 166 28 Prague 6, Czech Republic. Ludek.Joska@vscht.cz
- 245 10
- $a Corrosion behavior of palladium-silver-copper alloys in model saliva / $c L Joska, M Poddana, J Leitner
- 520 9_
- $a OBJECTIVES: Palladium-silver system alloyed with other metals represents one of possible material choices in prosthetics. Its corrosion properties are influenced by minority components added in order to obtain the properties required for stomatological purposes. The objective of this work was to ascertain the influence of copper on the corrosion mechanism of palladium-silver alloys. METHODS: Corrosion properties of four palladium-silver-copper alloys were compared with the behavior of the palladium-silver binary system. Standard electrochemical measurements in a model saliva solution were complemented with an XPS analysis of the specimens surface. Experimental data were compared with the results of thermodynamic analysis. RESULTS: The foregoing study revealed formation of a saline layer of insoluble silver compounds as the dominant feature of the corrosion mechanism in a binary system. This process is suppressed in ternary alloys where electrochemical reactions of copper take place on the alloy-electrolyte phase boundary leading to the formation of a layer based on copper oxides. SIGNIFICANCE: The alloying of the palladium-silver binary system with copper results in an important change in the corrosion behavior of ternary alloys. A change in the mechanism of interaction with the environment leads to susceptibility to non-uniform corrosion.
- 590 __
- $a bohemika - dle Pubmed
- 650 12
- $a měď $x chemie $7 D003300
- 650 02
- $a koroze $7 D003343
- 650 12
- $a zubní slitiny $x chemie $7 D003722
- 650 02
- $a elektrochemie $7 D004563
- 650 02
- $a mikroanalýza elektronovou sondou $7 D004577
- 650 02
- $a lidé $7 D006801
- 650 02
- $a testování materiálů $7 D008422
- 650 12
- $a palladium $x chemie $7 D010165
- 650 02
- $a potenciometrie $7 D011199
- 650 12
- $a náhrada slin $x chemie $7 D012464
- 650 12
- $a stříbro $x chemie $7 D012834
- 650 02
- $a povrchové vlastnosti $7 D013499
- 650 02
- $a termodynamika $7 D013816
- 650 02
- $a časové faktory $7 D013997
- 655 _2
- $a srovnávací studie $7 D003160
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Poddaná, Marcela $7 xx0108260 $u Institute of Chemical Technology, Department of Metals and Corrosion Engineering, Technicka 5, 166 28 Prague 6, Czech Republic
- 700 1_
- $a Leitner, Jindřich, $d 1956- $7 ola2005262715 $u Institute of Chemical Technology, Department of Solid State Engineering, Technicka 5, 166 28 Prague 6, Czech Republic
- 773 0_
- $t Dental Materials $x 0109-5641 $g Roč. 24, č. 8 (2008), s. 1009-1016 $p Dent Mater $w MED00001334
- 910 __
- $a ABA008 $y 4 $z 0
- 990 __
- $a 20140225113753 $b ABA008
- 991 __
- $a 20190104125759 $b ABA008
- 999 __
- $a ok $b bmc $g 1014335 $s 845912
- BAS __
- $a 3
- BMC __
- $a 2008 $b 24 $c 8 $d 1009-1016 $x MED00001334 $i 0109-5641 $m Dental materials $n Dent Mater
- GRA __
- $a NR9124 $p MZ0
- LZP __
- $a NLK 2014-02/lpbo