-
Something wrong with this record ?
Microfluidic tool coupled with electrochemical assay for detection of lactoferrin isolated by antibody-modified paramagnetic beads
O. Zitka, S. Krizkova, S. Skalickova, D. Dospivova, V. Adam, R. Kizek,
Language English Country Germany
Document type Evaluation Study, Journal Article, Research Support, Non-U.S. Gov't
- MeSH
- Equipment Design MeSH
- Adult MeSH
- Electrochemical Techniques instrumentation MeSH
- Antibodies, Immobilized chemistry MeSH
- Lactoferrin analysis isolation & purification MeSH
- Humans MeSH
- Limit of Detection MeSH
- Magnets chemistry MeSH
- Flow Injection Analysis instrumentation MeSH
- Saliva chemistry MeSH
- Animals MeSH
- Check Tag
- Adult MeSH
- Humans MeSH
- Male MeSH
- Animals MeSH
- Publication type
- Journal Article MeSH
- Evaluation Study MeSH
- Research Support, Non-U.S. Gov't MeSH
Lactoferrin (LF) is approximately 80 kDa iron-binding protein, which is important part of saliva and other body fluids. Due to its ability to bind metal ions, it has many biologically important functions. In this study, a method for the isolation of LF from a biological sample using robotically prepared antibody-modified paramagnetic particles was developed using robotic pipetting station. The method consisted of the following optimised steps. Protein G was bound on the paramagnetic particles, on which goat antibody (10 μg) was linked. LF was subsequently added to microtitration plate, which had affinity to goat antibody and the interaction lasted for 30 min. We found that the highest signals were obtained using the combination of goat antibody 1:3000, murine antibody 1:5000 and conjugate 1:1500. Horseradish peroxidase reducing 3,3,5,5-tetramethylbenzidine (TMB) was linked to the merged complex. The resulted product of this reaction was subsequently analysed spectrometrically with detection limit (3 S/N) as 5 ng/mL. In addition, we also determined TMB by stopped flow injection analysis with electrochemical detection. The limit of detection (3 S/N) was estimated as 0.1 μg/mL. To compare spectrometric and electrochemical approach for detection of TMB, calibration range of bead-LF-antibodies complex was prepared and was determined using a least-squares correlation with coefficient R² higher than 0.95, indicating a very good agreement of the results obtained.
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc14050808
- 003
- CZ-PrNML
- 005
- 20140402114829.0
- 007
- ta
- 008
- 140401s2013 gw f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1002/elps.201200631 $2 doi
- 035 __
- $a (PubMed)24024242
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a gw
- 100 1_
- $a Zitka, Ondrej
- 245 10
- $a Microfluidic tool coupled with electrochemical assay for detection of lactoferrin isolated by antibody-modified paramagnetic beads / $c O. Zitka, S. Krizkova, S. Skalickova, D. Dospivova, V. Adam, R. Kizek,
- 520 9_
- $a Lactoferrin (LF) is approximately 80 kDa iron-binding protein, which is important part of saliva and other body fluids. Due to its ability to bind metal ions, it has many biologically important functions. In this study, a method for the isolation of LF from a biological sample using robotically prepared antibody-modified paramagnetic particles was developed using robotic pipetting station. The method consisted of the following optimised steps. Protein G was bound on the paramagnetic particles, on which goat antibody (10 μg) was linked. LF was subsequently added to microtitration plate, which had affinity to goat antibody and the interaction lasted for 30 min. We found that the highest signals were obtained using the combination of goat antibody 1:3000, murine antibody 1:5000 and conjugate 1:1500. Horseradish peroxidase reducing 3,3,5,5-tetramethylbenzidine (TMB) was linked to the merged complex. The resulted product of this reaction was subsequently analysed spectrometrically with detection limit (3 S/N) as 5 ng/mL. In addition, we also determined TMB by stopped flow injection analysis with electrochemical detection. The limit of detection (3 S/N) was estimated as 0.1 μg/mL. To compare spectrometric and electrochemical approach for detection of TMB, calibration range of bead-LF-antibodies complex was prepared and was determined using a least-squares correlation with coefficient R² higher than 0.95, indicating a very good agreement of the results obtained.
- 650 _2
- $a dospělí $7 D000328
- 650 _2
- $a zvířata $7 D000818
- 650 _2
- $a imobilizační protilátky $x chemie $7 D055910
- 650 _2
- $a elektrochemické techniky $x přístrojové vybavení $7 D055664
- 650 _2
- $a design vybavení $7 D004867
- 650 _2
- $a průtoková injekční analýza $x přístrojové vybavení $7 D017022
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a laktoferrin $x analýza $x izolace a purifikace $7 D007781
- 650 _2
- $a limita detekce $7 D057230
- 650 _2
- $a magnety $x chemie $7 D059346
- 650 _2
- $a mužské pohlaví $7 D008297
- 650 _2
- $a sliny $x chemie $7 D012463
- 655 _2
- $a hodnotící studie $7 D023362
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Krizkova, Sona $u -
- 700 1_
- $a Skalickova, Sylvie $u -
- 700 1_
- $a Dospivova, Dana $u -
- 700 1_
- $a Adam, Vojtěch $u - $7 xx0064599
- 700 1_
- $a Kizek, Rene $u -
- 773 0_
- $w MED00001508 $t Electrophoresis $x 1522-2683 $g Roč. 34, č. 14 (2013), s. 2120-8
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/24024242 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20140401 $b ABA008
- 991 __
- $a 20140402114909 $b ABA008
- 999 __
- $a ok $b bmc $g 1017944 $s 849388
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2013 $b 34 $c 14 $d 2120-8 $i 1522-2683 $m Electrophoresis $n Electrophoresis $x MED00001508
- LZP __
- $a Pubmed-20140401