• Je něco špatně v tomto záznamu ?

Hydrophilic interaction liquid chromatography with tandem mass spectrometric detection applied for analysis of pteridines in two Graphosoma species (Insecta: Heteroptera)

P. Kozlík, J. Krajíček, K. Kalíková, E. Tesařová, R. Cabala, A. Exnerová, P. Stys, Z. Bosáková,

. 2013 ; 930 (-) : 82-9.

Jazyk angličtina Země Nizozemsko

Typ dokumentu časopisecké články, práce podpořená grantem

Perzistentní odkaz   https://www.medvik.cz/link/bmc14051030

A new separation method involving hydrophilic interaction chromatography with tandem mass spectrometric detection has been developed for the analysis of pteridines, namely biopterin, isoxanthopterin, leucopterin, neopterin, xanthopterin and erythropterin in the cuticle of heteropteran insect species. Two columns, Atlantis HILIC Silica and ZIC(®)-HILIC were tested for the separation of these pteridines. The effect of organic modifier content, buffer type, concentration and pH in mobile phase on retention and separation behavior of the selected pteridines was studied and the separation mechanism was also investigated. The optimized conditions for the separation of pteridines consisted of ZIC(®)-HILIC column, mobile phase composed of acetonitrile/5mM ammonium acetate, pH 6.80, 85/15 (v/v), flow rate 0.5mL/min and column temperature 30°C. Detection was performed by tandem mass spectrometry operating in electrospray ionization with Agilent Jet Stream technology using the selected reaction monitoring mode. The optimized method provided a linearity range from 0.3 to 5000ng/mL (r>0.9975) and repeatability with relative standard deviation<8.09% for all the studied pteridines. The method was applied to the analysis of pteridines in the cuticle of larvae and three adult color forms of Graphosoma lineatum and one form of Graphosoma semipunctatum (Insecta: Hemiptera: Heteroptera: Pentatomidae). The analysis shows that different forms of Graphosoma species can be characterized by different distribution of individual pteridines, which affects the coloration of various forms. Only isoxanthopterin was found in all the five forms tested.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc14051030
003      
CZ-PrNML
005      
20140414094612.0
007      
ta
008      
140401s2013 ne f 000 0|eng||
009      
AR
024    7_
$a 10.1016/j.jchromb.2013.05.004 $2 doi
035    __
$a (PubMed)23727871
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a ne
100    1_
$a Kozlík, Petr
245    10
$a Hydrophilic interaction liquid chromatography with tandem mass spectrometric detection applied for analysis of pteridines in two Graphosoma species (Insecta: Heteroptera) / $c P. Kozlík, J. Krajíček, K. Kalíková, E. Tesařová, R. Cabala, A. Exnerová, P. Stys, Z. Bosáková,
520    9_
$a A new separation method involving hydrophilic interaction chromatography with tandem mass spectrometric detection has been developed for the analysis of pteridines, namely biopterin, isoxanthopterin, leucopterin, neopterin, xanthopterin and erythropterin in the cuticle of heteropteran insect species. Two columns, Atlantis HILIC Silica and ZIC(®)-HILIC were tested for the separation of these pteridines. The effect of organic modifier content, buffer type, concentration and pH in mobile phase on retention and separation behavior of the selected pteridines was studied and the separation mechanism was also investigated. The optimized conditions for the separation of pteridines consisted of ZIC(®)-HILIC column, mobile phase composed of acetonitrile/5mM ammonium acetate, pH 6.80, 85/15 (v/v), flow rate 0.5mL/min and column temperature 30°C. Detection was performed by tandem mass spectrometry operating in electrospray ionization with Agilent Jet Stream technology using the selected reaction monitoring mode. The optimized method provided a linearity range from 0.3 to 5000ng/mL (r>0.9975) and repeatability with relative standard deviation<8.09% for all the studied pteridines. The method was applied to the analysis of pteridines in the cuticle of larvae and three adult color forms of Graphosoma lineatum and one form of Graphosoma semipunctatum (Insecta: Hemiptera: Heteroptera: Pentatomidae). The analysis shows that different forms of Graphosoma species can be characterized by different distribution of individual pteridines, which affects the coloration of various forms. Only isoxanthopterin was found in all the five forms tested.
650    _2
$a zvířata $7 D000818
650    _2
$a chromatografie kapalinová $x metody $7 D002853
650    _2
$a Heteroptera $x chemie $7 D020062
650    _2
$a hydrofobní a hydrofilní interakce $7 D057927
650    _2
$a limita detekce $7 D057230
650    _2
$a pteridiny $x analýza $x chemie $7 D011621
650    _2
$a reprodukovatelnost výsledků $7 D015203
650    _2
$a tandemová hmotnostní spektrometrie $x metody $7 D053719
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Krajíček, Jan $u -
700    1_
$a Kalíková, Květa $u -
700    1_
$a Tesařová, Eva $u -
700    1_
$a Cabala, Radomír $u -
700    1_
$a Exnerová, Alice $u -
700    1_
$a Stys, Pavel $u -
700    1_
$a Bosáková, Zuzana $u -
773    0_
$w MED00006642 $t Journal of chromatography. B, Analytical technologies in the biomedical and life sciences $x 1873-376X $g Roč. 930, č. - (2013), s. 82-9
856    41
$u https://pubmed.ncbi.nlm.nih.gov/23727871 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20140401 $b ABA008
991    __
$a 20140414094708 $b ABA008
999    __
$a ok $b bmc $g 1018166 $s 849610
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2013 $b 930 $c - $d 82-9 $i 1873-376X $m Journal of chromatography. B, Analytical technologies in the biomedical and life sciences $n J Chromatogr B Analyt Technol Biomed Life Sci $x MED00006642
LZP    __
$a Pubmed-20140401

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...