• Je něco špatně v tomto záznamu ?

A simple physical phantom for an intercomparison exercise on 241Am activity determination in the skull

T. Vrba, I. Malátová, P. Fojtík, M. Fülöp, P. Ragan,

. 2014 ; 158 (2) : 224-9.

Jazyk angličtina Země Anglie, Velká Británie

Typ dokumentu časopisecké články, práce podpořená grantem

Perzistentní odkaz   https://www.medvik.cz/link/bmc14074631

A simple hemispherical phantom has been designed and prepared for the EURADOS intercomparison exercise on (241)Am activity determination in the skull (2011-13). The phantom consists of three parts that substitute bone and soft tissues. (241)Am is deposited on the surfaces of the bone-substituting part. The design and assumed composition of phantom parts are discussed. A preparation of the voxel representation of the phantom is described. The spectrum of a real measurement of the physical phantom agrees well with the simulation. The physical phantom, and its voxel representation, is provided to the participants of the intercomparison exercise.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc14074631
003      
CZ-PrNML
005      
20141009125411.0
007      
ta
008      
141006s2014 enk f 000 0|eng||
009      
AR
024    7_
$a 10.1093/rpd/nct213 $2 doi
035    __
$a (PubMed)24080780
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a enk
100    1_
$a Vrba, T $u Faculty of Nuclear Sciences and Physical Engineering, Czech Technical University in Prague, Břehová 7, Prague 115 19, Czech Republic.
245    12
$a A simple physical phantom for an intercomparison exercise on 241Am activity determination in the skull / $c T. Vrba, I. Malátová, P. Fojtík, M. Fülöp, P. Ragan,
520    9_
$a A simple hemispherical phantom has been designed and prepared for the EURADOS intercomparison exercise on (241)Am activity determination in the skull (2011-13). The phantom consists of three parts that substitute bone and soft tissues. (241)Am is deposited on the surfaces of the bone-substituting part. The design and assumed composition of phantom parts are discussed. A preparation of the voxel representation of the phantom is described. The spectrum of a real measurement of the physical phantom agrees well with the simulation. The physical phantom, and its voxel representation, is provided to the participants of the intercomparison exercise.
650    _2
$a americium $x analýza $7 D000576
650    _2
$a kosti a kostní tkáň $x radioizotopová diagnostika $7 D001842
650    _2
$a kalibrace $7 D002138
650    _2
$a design vybavení $7 D004867
650    _2
$a metoda Monte Carlo $7 D009010
650    _2
$a fantomy radiodiagnostické $7 D019047
650    _2
$a fotony $7 D017785
650    _2
$a polyurethany $x chemie $7 D011140
650    _2
$a monitorování radiace $x metody $7 D011834
650    _2
$a radiometrie $x metody $x normy $7 D011874
650    _2
$a reprodukovatelnost výsledků $7 D015203
650    _2
$a lebka $x účinky záření $7 D012886
650    _2
$a počítačová rentgenová tomografie $7 D014057
651    _2
$a Česká republika $7 D018153
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Malátová, I
700    1_
$a Fojtík, P
700    1_
$a Fülöp, M
700    1_
$a Ragan, P
773    0_
$w MED00004029 $t Radiation protection dosimetry $x 1742-3406 $g Roč. 158, č. 2 (2014), s. 224-9
856    41
$u https://pubmed.ncbi.nlm.nih.gov/24080780 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20141006 $b ABA008
991    __
$a 20141009125800 $b ABA008
999    __
$a ok $b bmc $g 1042514 $s 873543
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2014 $b 158 $c 2 $d 224-9 $i 1742-3406 $m Radiation protection dosimetry $n Radiat Prot Dosimetry $x MED00004029
LZP    __
$a Pubmed-20141006

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...