-
Je něco špatně v tomto záznamu ?
Determination of thermodynamic values of acidic dissociation constants and complexation constants of profens and their utilization for optimization of separation conditions by Simul 5 Complex
M. Riesová, J. Svobodová, K. Ušelová, Z. Tošner, I. Zusková, B. Gaš,
Jazyk angličtina Země Nizozemsko
Typ dokumentu časopisecké články, práce podpořená grantem
- MeSH
- antiflogistika nesteroidní chemie MeSH
- beta-cyklodextriny chemie MeSH
- elektroforéza kapilární metody MeSH
- flurbiprofen chemie MeSH
- ibuprofen chemie MeSH
- ketoprofen chemie MeSH
- koncentrace vodíkových iontů MeSH
- magnetická rezonanční spektroskopie MeSH
- naproxen chemie MeSH
- osmolární koncentrace MeSH
- počítačová simulace MeSH
- software MeSH
- termodynamika MeSH
- viskozita MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
In this paper we determine acid dissociation constants, limiting ionic mobilities, complexation constants with β-cyclodextrin or heptakis(2,3,6-tri-O-methyl)-β-cyclodextrin, and mobilities of resulting complexes of profens, using capillary zone electrophoresis and affinity capillary electrophoresis. Complexation parameters are determined for both neutral and fully charged forms of profens and further corrected for actual ionic strength and variable viscosity in order to obtain thermodynamic values of complexation constants. The accuracy of obtained complexation parameters is verified by multidimensional nonlinear regression of affinity capillary electrophoretic data, which provides the acid dissociation and complexation parameters within one set of measurements, and by NMR technique. A good agreement among all discussed methods was obtained. Determined complexation parameters were used as input parameters for simulations of electrophoretic separation of profens by Simul 5 Complex. An excellent agreement of experimental and simulated results was achieved in terms of positions, shapes, and amplitudes of analyte peaks, confirming the applicability of Simul 5 Complex to complex systems, and accuracy of obtained physical-chemical constants. Simultaneously, we were able to demonstrate the influence of electromigration dispersion on the separation efficiency, which is not possible using the common theoretical approaches, and predict the electromigration order reversals of profen peaks. We have shown that determined acid dissociation and complexation parameters in combination with tool Simul 5 Complex software can be used for optimization of separation conditions in capillary electrophoresis.
NMR Laboratory Charles University Prague Faculty of Science Prague Czech Republic
Ruprecht Karls Universität Heidelberg Organisch Chemisches Institut Heidelberg Germany
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc15007930
- 003
- CZ-PrNML
- 005
- 20150306132950.0
- 007
- ta
- 008
- 150306s2014 ne f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1016/j.chroma.2014.08.070 $2 doi
- 035 __
- $a (PubMed)25213298
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a ne
- 100 1_
- $a Riesová, Martina $u Charles University in Prague, Faculty of Science, Department of Physical and Macromolecular Chemistry, Prague, Czech Republic.
- 245 10
- $a Determination of thermodynamic values of acidic dissociation constants and complexation constants of profens and their utilization for optimization of separation conditions by Simul 5 Complex / $c M. Riesová, J. Svobodová, K. Ušelová, Z. Tošner, I. Zusková, B. Gaš,
- 520 9_
- $a In this paper we determine acid dissociation constants, limiting ionic mobilities, complexation constants with β-cyclodextrin or heptakis(2,3,6-tri-O-methyl)-β-cyclodextrin, and mobilities of resulting complexes of profens, using capillary zone electrophoresis and affinity capillary electrophoresis. Complexation parameters are determined for both neutral and fully charged forms of profens and further corrected for actual ionic strength and variable viscosity in order to obtain thermodynamic values of complexation constants. The accuracy of obtained complexation parameters is verified by multidimensional nonlinear regression of affinity capillary electrophoretic data, which provides the acid dissociation and complexation parameters within one set of measurements, and by NMR technique. A good agreement among all discussed methods was obtained. Determined complexation parameters were used as input parameters for simulations of electrophoretic separation of profens by Simul 5 Complex. An excellent agreement of experimental and simulated results was achieved in terms of positions, shapes, and amplitudes of analyte peaks, confirming the applicability of Simul 5 Complex to complex systems, and accuracy of obtained physical-chemical constants. Simultaneously, we were able to demonstrate the influence of electromigration dispersion on the separation efficiency, which is not possible using the common theoretical approaches, and predict the electromigration order reversals of profen peaks. We have shown that determined acid dissociation and complexation parameters in combination with tool Simul 5 Complex software can be used for optimization of separation conditions in capillary electrophoresis.
- 650 _2
- $a antiflogistika nesteroidní $x chemie $7 D000894
- 650 _2
- $a počítačová simulace $7 D003198
- 650 _2
- $a elektroforéza kapilární $x metody $7 D019075
- 650 _2
- $a flurbiprofen $x chemie $7 D005480
- 650 _2
- $a koncentrace vodíkových iontů $7 D006863
- 650 _2
- $a ibuprofen $x chemie $7 D007052
- 650 _2
- $a ketoprofen $x chemie $7 D007660
- 650 _2
- $a magnetická rezonanční spektroskopie $7 D009682
- 650 _2
- $a naproxen $x chemie $7 D009288
- 650 _2
- $a osmolární koncentrace $7 D009994
- 650 _2
- $a software $7 D012984
- 650 _2
- $a termodynamika $7 D013816
- 650 _2
- $a viskozita $7 D014783
- 650 _2
- $a beta-cyklodextriny $x chemie $7 D047392
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Svobodová, Jana $u Charles University in Prague, Faculty of Science, Department of Physical and Macromolecular Chemistry, Prague, Czech Republic; Ruprecht-Karls-Universität Heidelberg, Organisch-Chemisches Institut, Heidelberg, Germany. Electronic address: svobod.j@natur.cuni.cz.
- 700 1_
- $a Ušelová, Kateřina $u Charles University in Prague, Faculty of Science, Department of Physical and Macromolecular Chemistry, Prague, Czech Republic.
- 700 1_
- $a Tošner, Zdeněk $u NMR Laboratory, Charles University in Prague, Faculty of Science, Prague, Czech Republic.
- 700 1_
- $a Zusková, Iva $u Charles University in Prague, Faculty of Science, Department of Physical and Macromolecular Chemistry, Prague, Czech Republic.
- 700 1_
- $a Gaš, Bohuslav $u Charles University in Prague, Faculty of Science, Department of Physical and Macromolecular Chemistry, Prague, Czech Republic.
- 773 0_
- $w MED00004962 $t Journal of chromatography. A $x 1873-3778 $g Roč. 1364, č. - (2014), s. 276-88
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/25213298 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20150306 $b ABA008
- 991 __
- $a 20150306133221 $b ABA008
- 999 __
- $a ok $b bmc $g 1065203 $s 890730
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2014 $b 1364 $c - $d 276-88 $i 1873-3778 $m Journal of chromatography. A, Including electrophoresis and other separation methods $n J Chromatogr A $x MED00004962
- LZP __
- $a Pubmed-20150306