Je něco špatně v tomto záznamu ?
Bipolar thermofusion BiClamp 150 in thyroidectomy: a review of 1156 operations
T. Pniak, M. Formánek, P. Matoušek, K. Zeleník, P. Komínek,
Jazyk angličtina Země Spojené státy americké
Typ dokumentu časopisecké články
NLK
Free Medical Journals
od 2013
PubMed Central
od 2013
Europe PubMed Central
od 2013
ProQuest Central
od 2013
Open Access Digital Library
od 2001-01-01
Open Access Digital Library
od 2012-12-04
Open Access Digital Library
od 2013-01-01
CINAHL Plus with Full Text (EBSCOhost)
od 2013-01-01
Medline Complete (EBSCOhost)
od 2013-01-01
Health & Medicine (ProQuest)
od 2013
Wiley-Blackwell Open Access Titles
od 2001
ROAD: Directory of Open Access Scholarly Resources
od 2013
PubMed
24829915
DOI
10.1155/2014/707265
Knihovny.cz E-zdroje
- MeSH
- chirurgické nástroje * MeSH
- délka operace MeSH
- lidé MeSH
- ligace MeSH
- štítná žláza chirurgie MeSH
- tyreoidektomie * MeSH
- Check Tag
- lidé MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
OBJECTIVES: To compare the bipolar thermofusion BiClamp 150 with conventional ligature techniques for thyroid gland surgery, and report the advantages/disadvantages of both techniques. METHODS: In this retrospective comparative study, all thyroid gland operations performed in the ENT Clinic Faculty Hospital Ostrava from 2006 to 2013 were included (1156 operations, 2122 lobes). Patients were categorized into two groups according to the type of vessel sealing method used, group I (BiClamp, n = 819 operations) and group II (conventional ligature, n = 337 operations). The number of revision surgeries due to wound hematoma was recorded as a bleeding event. Statistical analysis of the complication rate (bleeding rate, recurrent nerve palsy) and time of duration was performed. RESULTS: The rate of revision surgery performed due to postoperative wound hematoma was significantly lower in group I (15/819, 1.83%) compared with group II (14/337, 4.15%) (P = 0.022). There was no statistically significant difference in the frequency of recurrent laryngeal nerve palsy between groups I and II (P = 0.36). The average surgery time was significantly shorter in group I (P < 0.001). CONCLUSION: Bipolar thermofusion BiClamp is an effective vessel sealing method that leads to a significant reduction in postoperative wound bleeding rates and reduces surgical time compared with conventional vessel ligature.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc15008050
- 003
- CZ-PrNML
- 005
- 20250422081043.0
- 007
- ta
- 008
- 150306s2014 xxu f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1155/2014/707265 $2 doi
- 035 __
- $a (PubMed)24829915
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xxu
- 100 1_
- $a Pniak, Tomáš $u Department of Otolaryngology, University Hospital Ostrava, 17 Listopadu 1790, 708 52 Ostrava, Czech Republic. $7 xx0082616
- 245 10
- $a Bipolar thermofusion BiClamp 150 in thyroidectomy: a review of 1156 operations / $c T. Pniak, M. Formánek, P. Matoušek, K. Zeleník, P. Komínek,
- 520 9_
- $a OBJECTIVES: To compare the bipolar thermofusion BiClamp 150 with conventional ligature techniques for thyroid gland surgery, and report the advantages/disadvantages of both techniques. METHODS: In this retrospective comparative study, all thyroid gland operations performed in the ENT Clinic Faculty Hospital Ostrava from 2006 to 2013 were included (1156 operations, 2122 lobes). Patients were categorized into two groups according to the type of vessel sealing method used, group I (BiClamp, n = 819 operations) and group II (conventional ligature, n = 337 operations). The number of revision surgeries due to wound hematoma was recorded as a bleeding event. Statistical analysis of the complication rate (bleeding rate, recurrent nerve palsy) and time of duration was performed. RESULTS: The rate of revision surgery performed due to postoperative wound hematoma was significantly lower in group I (15/819, 1.83%) compared with group II (14/337, 4.15%) (P = 0.022). There was no statistically significant difference in the frequency of recurrent laryngeal nerve palsy between groups I and II (P = 0.36). The average surgery time was significantly shorter in group I (P < 0.001). CONCLUSION: Bipolar thermofusion BiClamp is an effective vessel sealing method that leads to a significant reduction in postoperative wound bleeding rates and reduces surgical time compared with conventional vessel ligature.
- 650 _2
- $a ženské pohlaví $7 D005260
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a ligace $7 D008026
- 650 _2
- $a mužské pohlaví $7 D008297
- 650 _2
- $a délka operace $7 D061646
- 650 12
- $a chirurgické nástroje $7 D013525
- 650 _2
- $a štítná žláza $x chirurgie $7 D013961
- 650 12
- $a tyreoidektomie $7 D013965
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Formánek, Martin $u Department of Otolaryngology, University Hospital Ostrava, 17 Listopadu 1790, 708 52 Ostrava, Czech Republic.
- 700 1_
- $a Matoušek, Petr, $d 1973- $u Department of Otolaryngology, University Hospital Ostrava, 17 Listopadu 1790, 708 52 Ostrava, Czech Republic. $7 xx0068189
- 700 1_
- $a Zeleník, Karol $u Department of Otolaryngology, University Hospital Ostrava, 17 Listopadu 1790, 708 52 Ostrava, Czech Republic.
- 700 1_
- $a Komínek, Pavel $u Department of Otolaryngology, University Hospital Ostrava, 17 Listopadu 1790, 708 52 Ostrava, Czech Republic.
- 773 0_
- $w MED00182164 $t BioMed research international $x 2314-6141 $g Roč. 2014 (2014), s. 707265
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/24829915 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20150306 $b ABA008
- 991 __
- $a 20250422081044 $b ABA008
- 999 __
- $a ok $b bmc $g 1065323 $s 890850
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2014 $b 2014 $c - $d 707265 $i 2314-6141 $m BioMed research international $n Biomed Res Int $x MED00182164
- LZP __
- $a Pubmed-20150306