• Je něco špatně v tomto záznamu ?

Comparison of five integrative samplers in laboratory for the monitoring of indicator and dioxin-like polychlorinated biphenyls in water

R. Jacquet, C. Miège, F. Smedes, C. Tixier, J. Tronczynski, A. Togola, C. Berho, I. Valor, J. Llorca, B. Barillon, P. Marchand, M. Coquery,

. 2014 ; 98 (-) : 18-27.

Jazyk angličtina Země Anglie, Velká Británie

Typ dokumentu srovnávací studie, časopisecké články, práce podpořená grantem

Perzistentní odkaz   https://www.medvik.cz/link/bmc15008522

This study aimed at evaluating and comparing five integrative samplers for the monitoring of indicator and dioxin-like polychlorinated biphenyls (PCBs) in water: semi-permeable membrane device (SPMD), silicone rubber, low-density polyethylene (LDPE) strip, Chemcatcher and a continuous-flow integrative sampler (CFIS). These samplers were spiked with performance reference compounds (PRCs) and then simultaneously exposed under constant agitation and temperature in a 200 L stainless steel tank for periods ranging from one day to three months. A constant PCB concentration of about 1 ng·L(-1) was achieved by immersing a large amount of silicone rubber sheets ("dosing sheets") spiked with the target PCBs. The uptake of PCBs in the five samplers showed overall good repeatability and their accumulation was linear with time. The samplers SPMD, silicone rubber and LDPE strip were the most promising in terms of achieving low limits of quantification. Time-weighted average (TWA) concentrations of PCBs in water were estimated from uptake of PCBs using the sampling rates calculated from the release of PRCs. Except for Chemcatcher, a good agreement was found between the different samplers and TWA concentrations ranged between 0.4 and 2.8 times the nominal water concentration. Finally, the influence of calculation methods (sampler-water partition coefficients, selected PRCs, models) on final TWA concentrations was studied.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc15008522
003      
CZ-PrNML
005      
20150306132846.0
007      
ta
008      
150306s2014 enk f 000 0|eng||
009      
AR
024    7_
$a 10.1016/j.chemosphere.2013.09.011 $2 doi
035    __
$a (PubMed)24200044
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a enk
100    1_
$a Jacquet, Romain $u Irstea, U.R. MALY, 5 rue de la Doua, CS70077, 69626 Villeurbanne Cedex, France.
245    10
$a Comparison of five integrative samplers in laboratory for the monitoring of indicator and dioxin-like polychlorinated biphenyls in water / $c R. Jacquet, C. Miège, F. Smedes, C. Tixier, J. Tronczynski, A. Togola, C. Berho, I. Valor, J. Llorca, B. Barillon, P. Marchand, M. Coquery,
520    9_
$a This study aimed at evaluating and comparing five integrative samplers for the monitoring of indicator and dioxin-like polychlorinated biphenyls (PCBs) in water: semi-permeable membrane device (SPMD), silicone rubber, low-density polyethylene (LDPE) strip, Chemcatcher and a continuous-flow integrative sampler (CFIS). These samplers were spiked with performance reference compounds (PRCs) and then simultaneously exposed under constant agitation and temperature in a 200 L stainless steel tank for periods ranging from one day to three months. A constant PCB concentration of about 1 ng·L(-1) was achieved by immersing a large amount of silicone rubber sheets ("dosing sheets") spiked with the target PCBs. The uptake of PCBs in the five samplers showed overall good repeatability and their accumulation was linear with time. The samplers SPMD, silicone rubber and LDPE strip were the most promising in terms of achieving low limits of quantification. Time-weighted average (TWA) concentrations of PCBs in water were estimated from uptake of PCBs using the sampling rates calculated from the release of PRCs. Except for Chemcatcher, a good agreement was found between the different samplers and TWA concentrations ranged between 0.4 and 2.8 times the nominal water concentration. Finally, the influence of calculation methods (sampler-water partition coefficients, selected PRCs, models) on final TWA concentrations was studied.
650    _2
$a dioxiny $x analýza $7 D004147
650    _2
$a monitorování životního prostředí $x přístrojové vybavení $x metody $7 D004784
650    _2
$a polychlorované bifenyly $x analýza $7 D011078
650    _2
$a teplota $7 D013696
650    _2
$a polychlorované dibenzodioxiny $7 D000072317
650    _2
$a voda $x chemie $7 D014867
650    _2
$a chemické látky znečišťující vodu $x analýza $7 D014874
655    _2
$a srovnávací studie $7 D003160
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Miège, Cécile $u Irstea, U.R. MALY, 5 rue de la Doua, CS70077, 69626 Villeurbanne Cedex, France. Electronic address: cecile.miege@irstea.fr.
700    1_
$a Smedes, Foppe $u Deltares, PO Box 85467, 3508 AL, Utrecht, The Netherlands; Masaryk University, RECETOX, Kamenice 126/3, 625 00 Brno, Czech Republic.
700    1_
$a Tixier, Céline $u Ifremer, RBE-BE-LBCO, rue de l'Ile d'Yeu, 44311 Nantes Cedex 3, France.
700    1_
$a Tronczynski, Jacek $u Ifremer, RBE-BE-LBCO, rue de l'Ile d'Yeu, 44311 Nantes Cedex 3, France.
700    1_
$a Togola, Anne $u BRGM, Monitoring and Analysis Division, 3 Avenue Claude Guillemin, 45060 Orléans, France.
700    1_
$a Berho, Catherine $u BRGM, Monitoring and Analysis Division, 3 Avenue Claude Guillemin, 45060 Orléans, France.
700    1_
$a Valor, Ignacio $u LABAQUA, c/Dracma 16-18, Poligono Industrial Las Atalayas, 03114 Alicante, Spain.
700    1_
$a Llorca, Julio $u LABAQUA, c/Dracma 16-18, Poligono Industrial Las Atalayas, 03114 Alicante, Spain.
700    1_
$a Barillon, Bruno $u Suez Environnement CIRSEE, 38 rue du Président Wilson, 78230 Le Peck, France.
700    1_
$a Marchand, P $u LUNAM University, ONIRIS, LABERCA, Atlanpôle -La Chantrerie, BP 50707, Nantes 44307, France.
700    1_
$a Coquery, Marina $u Irstea, U.R. MALY, 5 rue de la Doua, CS70077, 69626 Villeurbanne Cedex, France.
773    0_
$w MED00002124 $t Chemosphere $x 1879-1298 $g Roč. 98, č. - (2014), s. 18-27
856    41
$u https://pubmed.ncbi.nlm.nih.gov/24200044 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20150306 $b ABA008
991    __
$a 20150306133118 $b ABA008
999    __
$a ok $b bmc $g 1065795 $s 891322
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2014 $b 98 $c - $d 18-27 $i 1879-1298 $m Chemosphere $n Chemosphere $x MED00002124
LZP    __
$a Pubmed-20150306

Najít záznam

Citační ukazatele

Nahrávání dat ...

    Možnosti archivace