-
Je něco špatně v tomto záznamu ?
Comparison of five integrative samplers in laboratory for the monitoring of indicator and dioxin-like polychlorinated biphenyls in water
R. Jacquet, C. Miège, F. Smedes, C. Tixier, J. Tronczynski, A. Togola, C. Berho, I. Valor, J. Llorca, B. Barillon, P. Marchand, M. Coquery,
Jazyk angličtina Země Anglie, Velká Británie
Typ dokumentu srovnávací studie, časopisecké články, práce podpořená grantem
- MeSH
- chemické látky znečišťující vodu analýza MeSH
- dioxiny analýza MeSH
- monitorování životního prostředí přístrojové vybavení metody MeSH
- polychlorované bifenyly analýza MeSH
- polychlorované dibenzodioxiny MeSH
- teplota MeSH
- voda chemie MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- srovnávací studie MeSH
This study aimed at evaluating and comparing five integrative samplers for the monitoring of indicator and dioxin-like polychlorinated biphenyls (PCBs) in water: semi-permeable membrane device (SPMD), silicone rubber, low-density polyethylene (LDPE) strip, Chemcatcher and a continuous-flow integrative sampler (CFIS). These samplers were spiked with performance reference compounds (PRCs) and then simultaneously exposed under constant agitation and temperature in a 200 L stainless steel tank for periods ranging from one day to three months. A constant PCB concentration of about 1 ng·L(-1) was achieved by immersing a large amount of silicone rubber sheets ("dosing sheets") spiked with the target PCBs. The uptake of PCBs in the five samplers showed overall good repeatability and their accumulation was linear with time. The samplers SPMD, silicone rubber and LDPE strip were the most promising in terms of achieving low limits of quantification. Time-weighted average (TWA) concentrations of PCBs in water were estimated from uptake of PCBs using the sampling rates calculated from the release of PRCs. Except for Chemcatcher, a good agreement was found between the different samplers and TWA concentrations ranged between 0.4 and 2.8 times the nominal water concentration. Finally, the influence of calculation methods (sampler-water partition coefficients, selected PRCs, models) on final TWA concentrations was studied.
BRGM Monitoring and Analysis Division 3 Avenue Claude Guillemin 45060 Orléans France
Deltares PO Box 85467 3508 AL Utrecht The Netherlands
Ifremer RBE BE LBCO rue de l'Ile d'Yeu 44311 Nantes Cedex 3 France
Irstea U R MALY 5 rue de la Doua CS70077 69626 Villeurbanne Cedex France
LABAQUA c Dracma 16 18 Poligono Industrial Las Atalayas 03114 Alicante Spain
LUNAM University ONIRIS LABERCA Atlanpôle La Chantrerie BP 50707 Nantes 44307 France
Masaryk University RECETOX Kamenice 126 3 625 00 Brno Czech Republic
Suez Environnement CIRSEE 38 rue du Président Wilson 78230 Le Peck France
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc15008522
- 003
- CZ-PrNML
- 005
- 20150306132846.0
- 007
- ta
- 008
- 150306s2014 enk f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1016/j.chemosphere.2013.09.011 $2 doi
- 035 __
- $a (PubMed)24200044
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a enk
- 100 1_
- $a Jacquet, Romain $u Irstea, U.R. MALY, 5 rue de la Doua, CS70077, 69626 Villeurbanne Cedex, France.
- 245 10
- $a Comparison of five integrative samplers in laboratory for the monitoring of indicator and dioxin-like polychlorinated biphenyls in water / $c R. Jacquet, C. Miège, F. Smedes, C. Tixier, J. Tronczynski, A. Togola, C. Berho, I. Valor, J. Llorca, B. Barillon, P. Marchand, M. Coquery,
- 520 9_
- $a This study aimed at evaluating and comparing five integrative samplers for the monitoring of indicator and dioxin-like polychlorinated biphenyls (PCBs) in water: semi-permeable membrane device (SPMD), silicone rubber, low-density polyethylene (LDPE) strip, Chemcatcher and a continuous-flow integrative sampler (CFIS). These samplers were spiked with performance reference compounds (PRCs) and then simultaneously exposed under constant agitation and temperature in a 200 L stainless steel tank for periods ranging from one day to three months. A constant PCB concentration of about 1 ng·L(-1) was achieved by immersing a large amount of silicone rubber sheets ("dosing sheets") spiked with the target PCBs. The uptake of PCBs in the five samplers showed overall good repeatability and their accumulation was linear with time. The samplers SPMD, silicone rubber and LDPE strip were the most promising in terms of achieving low limits of quantification. Time-weighted average (TWA) concentrations of PCBs in water were estimated from uptake of PCBs using the sampling rates calculated from the release of PRCs. Except for Chemcatcher, a good agreement was found between the different samplers and TWA concentrations ranged between 0.4 and 2.8 times the nominal water concentration. Finally, the influence of calculation methods (sampler-water partition coefficients, selected PRCs, models) on final TWA concentrations was studied.
- 650 _2
- $a dioxiny $x analýza $7 D004147
- 650 _2
- $a monitorování životního prostředí $x přístrojové vybavení $x metody $7 D004784
- 650 _2
- $a polychlorované bifenyly $x analýza $7 D011078
- 650 _2
- $a teplota $7 D013696
- 650 _2
- $a polychlorované dibenzodioxiny $7 D000072317
- 650 _2
- $a voda $x chemie $7 D014867
- 650 _2
- $a chemické látky znečišťující vodu $x analýza $7 D014874
- 655 _2
- $a srovnávací studie $7 D003160
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Miège, Cécile $u Irstea, U.R. MALY, 5 rue de la Doua, CS70077, 69626 Villeurbanne Cedex, France. Electronic address: cecile.miege@irstea.fr.
- 700 1_
- $a Smedes, Foppe $u Deltares, PO Box 85467, 3508 AL, Utrecht, The Netherlands; Masaryk University, RECETOX, Kamenice 126/3, 625 00 Brno, Czech Republic.
- 700 1_
- $a Tixier, Céline $u Ifremer, RBE-BE-LBCO, rue de l'Ile d'Yeu, 44311 Nantes Cedex 3, France.
- 700 1_
- $a Tronczynski, Jacek $u Ifremer, RBE-BE-LBCO, rue de l'Ile d'Yeu, 44311 Nantes Cedex 3, France.
- 700 1_
- $a Togola, Anne $u BRGM, Monitoring and Analysis Division, 3 Avenue Claude Guillemin, 45060 Orléans, France.
- 700 1_
- $a Berho, Catherine $u BRGM, Monitoring and Analysis Division, 3 Avenue Claude Guillemin, 45060 Orléans, France.
- 700 1_
- $a Valor, Ignacio $u LABAQUA, c/Dracma 16-18, Poligono Industrial Las Atalayas, 03114 Alicante, Spain.
- 700 1_
- $a Llorca, Julio $u LABAQUA, c/Dracma 16-18, Poligono Industrial Las Atalayas, 03114 Alicante, Spain.
- 700 1_
- $a Barillon, Bruno $u Suez Environnement CIRSEE, 38 rue du Président Wilson, 78230 Le Peck, France.
- 700 1_
- $a Marchand, P $u LUNAM University, ONIRIS, LABERCA, Atlanpôle -La Chantrerie, BP 50707, Nantes 44307, France.
- 700 1_
- $a Coquery, Marina $u Irstea, U.R. MALY, 5 rue de la Doua, CS70077, 69626 Villeurbanne Cedex, France.
- 773 0_
- $w MED00002124 $t Chemosphere $x 1879-1298 $g Roč. 98, č. - (2014), s. 18-27
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/24200044 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20150306 $b ABA008
- 991 __
- $a 20150306133118 $b ABA008
- 999 __
- $a ok $b bmc $g 1065795 $s 891322
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2014 $b 98 $c - $d 18-27 $i 1879-1298 $m Chemosphere $n Chemosphere $x MED00002124
- LZP __
- $a Pubmed-20150306