Something wrong with this record ?
A portable device for fast analysis of explosives in the environment
L. Čapka, Z. Večeřa, P. Mikuška, J. Šesták, V. Kahle, A. Bumbová,
Language English Country Netherlands
Document type Journal Article, Research Support, Non-U.S. Gov't
- MeSH
- Aniline Compounds analysis MeSH
- Chromatography, Liquid instrumentation methods MeSH
- Nitrates analysis MeSH
- Peroxynitrous Acid analysis MeSH
- Luminescent Measurements MeSH
- Nitrobenzenes analysis MeSH
- Signal-To-Noise Ratio MeSH
- Soil chemistry MeSH
- Water chemistry MeSH
- Explosive Agents analysis MeSH
- Publication type
- Journal Article MeSH
- Research Support, Non-U.S. Gov't MeSH
A novel portable device for fast and sensitive analysis of explosives in environmental samples is presented. The developed system consists of miniaturized microcolumn liquid chromatograph, photolytic converter and chemiluminescence detector. The device is able to determine selectively nitramine- and nitroester- and most of nitroaromates-based explosives as well as inorganic nitrates at trace concentrations in water or soil extracts in less than 8 min. The device allows to analyze various environmental samples such as soils or water materials without previous preconcentration. Because of internal power supply, the device ensures 12h of continuous operation. Limits of detection of compounds of interest are in the range of concentrations from 5.0 × 10(-9)M to 8.0 × 10(-5)M for a signal-to-noise ratio of 3. Limits of quantification are in the range of concentrations from 1.7 × 10(-8)M to 2.7 × 10(-4)M for a signal-to-noise ratio of 10. The repeatability of the method (RSD=2.9-5.6%) was determined by repeated injections (n=10) of the standard samples during 4h.
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc15022799
- 003
- CZ-PrNML
- 005
- 20150729112350.0
- 007
- ta
- 008
- 150709s2015 ne f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1016/j.chroma.2015.02.041 $2 doi
- 035 __
- $a (PubMed)25736306
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a ne
- 100 1_
- $a Čapka, Lukáš $u Institute of Analytical Chemistry, Academy of Sciences of the Czech Republic, Veveří 97, 60200 Brno, Czech Republic. Electronic address: capka@iach.cz.
- 245 12
- $a A portable device for fast analysis of explosives in the environment / $c L. Čapka, Z. Večeřa, P. Mikuška, J. Šesták, V. Kahle, A. Bumbová,
- 520 9_
- $a A novel portable device for fast and sensitive analysis of explosives in environmental samples is presented. The developed system consists of miniaturized microcolumn liquid chromatograph, photolytic converter and chemiluminescence detector. The device is able to determine selectively nitramine- and nitroester- and most of nitroaromates-based explosives as well as inorganic nitrates at trace concentrations in water or soil extracts in less than 8 min. The device allows to analyze various environmental samples such as soils or water materials without previous preconcentration. Because of internal power supply, the device ensures 12h of continuous operation. Limits of detection of compounds of interest are in the range of concentrations from 5.0 × 10(-9)M to 8.0 × 10(-5)M for a signal-to-noise ratio of 3. Limits of quantification are in the range of concentrations from 1.7 × 10(-8)M to 2.7 × 10(-4)M for a signal-to-noise ratio of 10. The repeatability of the method (RSD=2.9-5.6%) was determined by repeated injections (n=10) of the standard samples during 4h.
- 650 _2
- $a aniliny $x analýza $7 D000814
- 650 _2
- $a chromatografie kapalinová $x přístrojové vybavení $x metody $7 D002853
- 650 _2
- $a výbušné látky $x analýza $7 D053834
- 650 _2
- $a luminiscenční měření $7 D008163
- 650 _2
- $a dusičnany $x analýza $7 D009566
- 650 _2
- $a nitrobenzeny $x analýza $7 D009578
- 650 _2
- $a kyselina peroxydusitá $x analýza $7 D030421
- 650 _2
- $a poměr signál - šum $7 D059629
- 650 _2
- $a půda $x chemie $7 D012987
- 650 _2
- $a voda $x chemie $7 D014867
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Večeřa, Zbyněk $u Institute of Analytical Chemistry, Academy of Sciences of the Czech Republic, Veveří 97, 60200 Brno, Czech Republic.
- 700 1_
- $a Mikuška, Pavel $u Institute of Analytical Chemistry, Academy of Sciences of the Czech Republic, Veveří 97, 60200 Brno, Czech Republic.
- 700 1_
- $a Šesták, Jozef $u Institute of Analytical Chemistry, Academy of Sciences of the Czech Republic, Veveří 97, 60200 Brno, Czech Republic.
- 700 1_
- $a Kahle, Vladislav $u Institute of Analytical Chemistry, Academy of Sciences of the Czech Republic, Veveří 97, 60200 Brno, Czech Republic.
- 700 1_
- $a Bumbová, Alena $u University of Defence, Kounicova 65, 66210 Brno, Czech Republic.
- 773 0_
- $w MED00004962 $t Journal of chromatography. A. Including electrophoresis and other separation methods $x 1873-3778 $g Roč. 1388, č. - (2015), s. 167-73
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/25736306 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20150709 $b ABA008
- 991 __
- $a 20150729112436 $b ABA008
- 999 __
- $a ok $b bmc $g 1083138 $s 905792
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2015 $b 1388 $c - $d 167-73 $i 1873-3778 $m Journal of chromatography. A, Including electrophoresis and other separation methods $n J Chromatogr A $x MED00004962 $o Including electrophoresis and other separation methods
- LZP __
- $a Pubmed-20150709