-
Je něco špatně v tomto záznamu ?
Retention and selectivity of basic drugs on solid-phase extraction sorbents: application to direct determination of β-blockers in urine
W. Boonjob, H. Sklenářová, FJ. Lara, AM. García-Campaña, P. Solich,
Jazyk angličtina Země Německo
Typ dokumentu hodnotící studie, časopisecké články, práce podpořená grantem
NLK
ProQuest Central
od 2011-01-01 do Před 1 rokem
Medline Complete (EBSCOhost)
od 2003-01-01 do Před 1 rokem
Health & Medicine (ProQuest)
od 2011-01-01 do Před 1 rokem
- MeSH
- adsorpce MeSH
- beta blokátory izolace a purifikace moč MeSH
- extrakce na pevné fázi přístrojové vybavení metody MeSH
- lidé MeSH
- molekulový imprinting MeSH
- polymery chemická syntéza chemie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- hodnotící studie MeSH
- práce podpořená grantem MeSH
Seven solid phase sorbent materials with reversed-phase, mixed-mode interactions (ion-exchange and reversed-phase), and molecularly imprinted polymers (MIP), namely Oasis HLB, Oasis MAX, Oasis MCX, Bond Elute Plexa, Bond Elute Plexa PAX, Bond Elute Plexa PCX, and SupelMIP sorbents, were investigated. The present study was focused on the retention and elution of pharmaceutically active substances based on several analyte-sorbent interaction properties. Basic drugs, such as β-blockers (i.e., atenolol, pindolol, acebutolol, metoprolol, labetalol, and propranolol) were selected as the model compounds for this study. These compounds are frequently encountered in anti-doping tests. The extraction efficiencies of the individual sorbents were compared based on the recovery of known amounts of the targeted analytes in a metered elution volume (500 μL) in three separate elution fractions. The elution efficiency of the total amount of the target analytes on various sorbents was not appreciably influenced by the volume of eluent required for complete elution. Based on the small matrix effects and clear baseline, SupelMIP was the most suitable sorbent for urine analysis. The relative analyte recoveries of the SPE-HPLC procedure proved satisfactory for the range from 94% to 105%, with an RSD ranging from 2% to 4%. The regression equations for all of the targeted compounds exhibited excellent linearity (r(2) > 0.9991) over the range of 10 to 1000 ng mL(-1). The limits of detection and quantification for the selected β-blocker compounds in urine were in the ranges of 0.6 to 2.0 ng mL(-1) and 2.0 to 6.7 ng mL(-1), respectively.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc15023446
- 003
- CZ-PrNML
- 005
- 20250114081628.0
- 007
- ta
- 008
- 150709s2014 gw f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1007/s00216-014-7753-4 $2 doi
- 035 __
- $a (PubMed)24788887
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a gw
- 100 1_
- $a Boonjob, Warunya $u Department of Analytical Chemistry, Faculty of Pharmacy, Charles University in Prague, Heyrovského 1203, 500 05, Hradec Králové, Czech Republic, boonjobw@faf.cuni.cz. $7 xx0327572
- 245 10
- $a Retention and selectivity of basic drugs on solid-phase extraction sorbents: application to direct determination of β-blockers in urine / $c W. Boonjob, H. Sklenářová, FJ. Lara, AM. García-Campaña, P. Solich,
- 520 9_
- $a Seven solid phase sorbent materials with reversed-phase, mixed-mode interactions (ion-exchange and reversed-phase), and molecularly imprinted polymers (MIP), namely Oasis HLB, Oasis MAX, Oasis MCX, Bond Elute Plexa, Bond Elute Plexa PAX, Bond Elute Plexa PCX, and SupelMIP sorbents, were investigated. The present study was focused on the retention and elution of pharmaceutically active substances based on several analyte-sorbent interaction properties. Basic drugs, such as β-blockers (i.e., atenolol, pindolol, acebutolol, metoprolol, labetalol, and propranolol) were selected as the model compounds for this study. These compounds are frequently encountered in anti-doping tests. The extraction efficiencies of the individual sorbents were compared based on the recovery of known amounts of the targeted analytes in a metered elution volume (500 μL) in three separate elution fractions. The elution efficiency of the total amount of the target analytes on various sorbents was not appreciably influenced by the volume of eluent required for complete elution. Based on the small matrix effects and clear baseline, SupelMIP was the most suitable sorbent for urine analysis. The relative analyte recoveries of the SPE-HPLC procedure proved satisfactory for the range from 94% to 105%, with an RSD ranging from 2% to 4%. The regression equations for all of the targeted compounds exhibited excellent linearity (r(2) > 0.9991) over the range of 10 to 1000 ng mL(-1). The limits of detection and quantification for the selected β-blocker compounds in urine were in the ranges of 0.6 to 2.0 ng mL(-1) and 2.0 to 6.7 ng mL(-1), respectively.
- 650 _2
- $a beta blokátory $x izolace a purifikace $x moč $7 D000319
- 650 _2
- $a adsorpce $7 D000327
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a molekulový imprinting $7 D054802
- 650 _2
- $a polymery $x chemická syntéza $x chemie $7 D011108
- 650 _2
- $a extrakce na pevné fázi $x přístrojové vybavení $x metody $7 D052616
- 655 _2
- $a hodnotící studie $7 D023362
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Sklenářová, Hana
- 700 1_
- $a Lara, Francisco J
- 700 1_
- $a García-Campaña, Ana M
- 700 1_
- $a Solich, Petr
- 773 0_
- $w MED00006638 $t Analytical and bioanalytical chemistry $x 1618-2650 $g Roč. 406, č. 17 (2014), s. 4207-15
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/24788887 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20150709 $b ABA008
- 991 __
- $a 20250114081625 $b ABA008
- 999 __
- $a ok $b bmc $g 1083783 $s 906439
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2014 $b 406 $c 17 $d 4207-15 $i 1618-2650 $m Analytical and bioanalytical chemistry $n Anal Bioanal Chem $x MED00006638
- LZP __
- $a Pubmed-20150709