-
Je něco špatně v tomto záznamu ?
pI-Control in Comparative Fluorescence Gel Electrophoresis (CoFGE) using amphoteric azo dyes
M. Hanneken, K. Šlais, S. König,
Jazyk angličtina Země Nizozemsko
Typ dokumentu časopisecké články
NLK
Directory of Open Access Journals
od 2014
Free Medical Journals
od 2014-12-01
PubMed Central
od 2014
Europe PubMed Central
od 2014 do 2020
Open Access Digital Library
od 2014-12-01
Open Access Digital Library
od 2014-01-01
Open Access Digital Library
od 2014-01-01
ROAD: Directory of Open Access Scholarly Resources
od 2014
- Publikační typ
- časopisecké články MeSH
Amphoteric azo dyes were used for internal control of pI values in Comparative two-dimensional Fluorescence Gel Electrophoresis (CoFGE) [1]. The 2D-gel images of separated Escherichia coli proteins as well as those of colored amphoteric dyes separated by isoelectric focussing are presented. The latter were used to correct for variation in the first electrophoretic dimension and further improve protein coordinate assignment in 2D-gel electrophoresis. Data tables are supplied to demonstrate pI-value calibration and the effect on the assignment of protein spot coordinates.
Core Unit Proteomics Interdisciplinary Center for Clinical Research University of Münster Germany
Institute of Analytical Chemistry of the ASCR v v i Brno Czech Republic
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc15031269
- 003
- CZ-PrNML
- 005
- 20210209120220.0
- 007
- ta
- 008
- 151005s2015 ne f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1016/j.dib.2015.03.007 $2 doi
- 035 __
- $a (PubMed)26217748
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a ne
- 100 1_
- $a Hanneken, Marina $u Core Unit Proteomics, Interdisciplinary Center for Clinical Research, University of Münster, Germany.
- 245 10
- $a pI-Control in Comparative Fluorescence Gel Electrophoresis (CoFGE) using amphoteric azo dyes / $c M. Hanneken, K. Šlais, S. König,
- 520 9_
- $a Amphoteric azo dyes were used for internal control of pI values in Comparative two-dimensional Fluorescence Gel Electrophoresis (CoFGE) [1]. The 2D-gel images of separated Escherichia coli proteins as well as those of colored amphoteric dyes separated by isoelectric focussing are presented. The latter were used to correct for variation in the first electrophoretic dimension and further improve protein coordinate assignment in 2D-gel electrophoresis. Data tables are supplied to demonstrate pI-value calibration and the effect on the assignment of protein spot coordinates.
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Šlais, Karel $u Institute of Analytical Chemistry of the ASCR, v. v. i., Brno, Czech Republic.
- 700 1_
- $a König, Simone $u Core Unit Proteomics, Interdisciplinary Center for Clinical Research, University of Münster, Germany.
- 773 0_
- $w MED00188041 $t Data in brief $x 2352-3409 $g Roč. 3, č. - (2015), s. 221-8
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/26217748 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20151005 $b ABA008
- 991 __
- $a 20210209120217 $b ABA008
- 999 __
- $a ind $b bmc $g 1092150 $s 914393
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2015 $b 3 $c - $d 221-8 $e 20150401 $i 2352-3409 $m Data in brief $n Data Brief $x MED00188041
- LZP __
- $a Pubmed-20151005