Detail
Článek
Článek online
FT
Medvik - BMČ
  • Je něco špatně v tomto záznamu ?

pI-Control in Comparative Fluorescence Gel Electrophoresis (CoFGE) using amphoteric azo dyes

M. Hanneken, K. Šlais, S. König,

. 2015 ; 3 (-) : 221-8. [pub] 20150401

Jazyk angličtina Země Nizozemsko

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc15031269

Amphoteric azo dyes were used for internal control of pI values in Comparative two-dimensional Fluorescence Gel Electrophoresis (CoFGE) [1]. The 2D-gel images of separated Escherichia coli proteins as well as those of colored amphoteric dyes separated by isoelectric focussing are presented. The latter were used to correct for variation in the first electrophoretic dimension and further improve protein coordinate assignment in 2D-gel electrophoresis. Data tables are supplied to demonstrate pI-value calibration and the effect on the assignment of protein spot coordinates.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc15031269
003      
CZ-PrNML
005      
20210209120220.0
007      
ta
008      
151005s2015 ne f 000 0|eng||
009      
AR
024    7_
$a 10.1016/j.dib.2015.03.007 $2 doi
035    __
$a (PubMed)26217748
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a ne
100    1_
$a Hanneken, Marina $u Core Unit Proteomics, Interdisciplinary Center for Clinical Research, University of Münster, Germany.
245    10
$a pI-Control in Comparative Fluorescence Gel Electrophoresis (CoFGE) using amphoteric azo dyes / $c M. Hanneken, K. Šlais, S. König,
520    9_
$a Amphoteric azo dyes were used for internal control of pI values in Comparative two-dimensional Fluorescence Gel Electrophoresis (CoFGE) [1]. The 2D-gel images of separated Escherichia coli proteins as well as those of colored amphoteric dyes separated by isoelectric focussing are presented. The latter were used to correct for variation in the first electrophoretic dimension and further improve protein coordinate assignment in 2D-gel electrophoresis. Data tables are supplied to demonstrate pI-value calibration and the effect on the assignment of protein spot coordinates.
655    _2
$a časopisecké články $7 D016428
700    1_
$a Šlais, Karel $u Institute of Analytical Chemistry of the ASCR, v. v. i., Brno, Czech Republic.
700    1_
$a König, Simone $u Core Unit Proteomics, Interdisciplinary Center for Clinical Research, University of Münster, Germany.
773    0_
$w MED00188041 $t Data in brief $x 2352-3409 $g Roč. 3, č. - (2015), s. 221-8
856    41
$u https://pubmed.ncbi.nlm.nih.gov/26217748 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20151005 $b ABA008
991    __
$a 20210209120217 $b ABA008
999    __
$a ind $b bmc $g 1092150 $s 914393
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2015 $b 3 $c - $d 221-8 $e 20150401 $i 2352-3409 $m Data in brief $n Data Brief $x MED00188041
LZP    __
$a Pubmed-20151005

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...