Model-based vs hybrid iterative reconstruction technique in ultralow-dose submillisievert CT colonography

L. Lambert, P. Ourednicek, J. Jahoda, A. Lambertova, J. Danes,

. 2015 ; 88 (1048) : 20140667. [pub] 20150121

Jazyk angličtina Země Anglie, Velká Británie

Typ dokumentu srovnávací studie, časopisecké články, práce podpořená grantem

Perzistentní odkaz   https://www.medvik.cz/link/bmc15031497

OBJECTIVE: To compare image quality of different reconstruction techniques in submillisievert ultralow-dose CT colonography (CTC) and to correlate colonic findings with subsequent optical colonoscopy. METHODS: 58 patients underwent ultralow-dose CTC. The images were reconstructed with filtered back projection (FBP), hybrid iterative reconstruction (HIR) or model-based iterative reconstruction (MBIR) techniques. In each segment, endoluminal noise (expressed as standard deviation of endoluminal density) was measured and image quality was rated on a five-point Likert scale by two independent readers. Colonic lesions were evaluated in consensus and correlated with subsequent optical colonoscopy where possible. RESULTS: The estimated radiation dose was 0.41 ± 0.05 mSv for the supine and 0.42 ± 0.04 mSv for the prone acquisitions. In the endoluminal view, the image quality was rated better in HIR, whereas better scores were obtained in MBIR in the cross-sectional view, where the endoluminal noise was the lowest (p < 0.0001). Five (26%) polyps were not identified using both computer-aided detection and endoluminal inspection in FBP images vs only one (5%) in MBIR and none in HIR images. CONCLUSION: This study showed that in submillisievert ultralow-dose CTC, the image quality for the endoluminal view is better when HIR is used, whereas MBIR yields superior images for the cross-sectional view. The inferior quality of images reconstructed with FBP may result in decreased detection of colonic lesions. ADVANCES IN KNOWLEDGE: Radiation dose from CTC can be safely reduced <1 mSv for both positions when iterative reconstruction is used. MBIR provides better image quality in the cross-sectional view and HIR in the endoluminal view.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc15031497
003      
CZ-PrNML
005      
20151014121717.0
007      
ta
008      
151005s2015 enk f 000 0|eng||
009      
AR
024    7_
$a 10.1259/bjr.20140667 $2 doi
035    __
$a (PubMed)25605346
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a enk
100    1_
$a Lambert, L $u 1 Department of Radiology, First Faculty of Medicine of Charles University in Prague, Prague, Czech Republic.
245    10
$a Model-based vs hybrid iterative reconstruction technique in ultralow-dose submillisievert CT colonography / $c L. Lambert, P. Ourednicek, J. Jahoda, A. Lambertova, J. Danes,
520    9_
$a OBJECTIVE: To compare image quality of different reconstruction techniques in submillisievert ultralow-dose CT colonography (CTC) and to correlate colonic findings with subsequent optical colonoscopy. METHODS: 58 patients underwent ultralow-dose CTC. The images were reconstructed with filtered back projection (FBP), hybrid iterative reconstruction (HIR) or model-based iterative reconstruction (MBIR) techniques. In each segment, endoluminal noise (expressed as standard deviation of endoluminal density) was measured and image quality was rated on a five-point Likert scale by two independent readers. Colonic lesions were evaluated in consensus and correlated with subsequent optical colonoscopy where possible. RESULTS: The estimated radiation dose was 0.41 ± 0.05 mSv for the supine and 0.42 ± 0.04 mSv for the prone acquisitions. In the endoluminal view, the image quality was rated better in HIR, whereas better scores were obtained in MBIR in the cross-sectional view, where the endoluminal noise was the lowest (p < 0.0001). Five (26%) polyps were not identified using both computer-aided detection and endoluminal inspection in FBP images vs only one (5%) in MBIR and none in HIR images. CONCLUSION: This study showed that in submillisievert ultralow-dose CTC, the image quality for the endoluminal view is better when HIR is used, whereas MBIR yields superior images for the cross-sectional view. The inferior quality of images reconstructed with FBP may result in decreased detection of colonic lesions. ADVANCES IN KNOWLEDGE: Radiation dose from CTC can be safely reduced <1 mSv for both positions when iterative reconstruction is used. MBIR provides better image quality in the cross-sectional view and HIR in the endoluminal view.
650    _2
$a senioři $7 D000368
650    _2
$a kolonografie počítačovou tomografií $x metody $7 D023881
650    _2
$a ženské pohlaví $7 D005260
650    _2
$a lidé $7 D006801
650    _2
$a mužské pohlaví $7 D008297
650    _2
$a lidé středního věku $7 D008875
650    _2
$a teoretické modely $7 D008962
650    _2
$a dávka záření $7 D011829
650    _2
$a rentgenový obraz - interpretace počítačová $x metody $7 D011857
655    _2
$a srovnávací studie $7 D003160
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Ourednicek, P
700    1_
$a Jahoda, J
700    1_
$a Lambertova, A
700    1_
$a Danes, J
773    0_
$w MED00000884 $t The British journal of radiology $x 1748-880X $g Roč. 88, č. 1048 (2015), s. 20140667
856    41
$u https://pubmed.ncbi.nlm.nih.gov/25605346 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20151005 $b ABA008
991    __
$a 20151014121907 $b ABA008
999    __
$a ok $b bmc $g 1092373 $s 914623
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2015 $b 88 $c 1048 $d 20140667 $e 20150121 $i 1748-880X $m British journal of radiology $n Br J Radiol $x MED00000884
LZP    __
$a Pubmed-20151005

Najít záznam

Citační ukazatele

Pouze přihlášení uživatelé

Možnosti archivace

Nahrávání dat ...