Detail
Article
Online article
FT
Medvik - BMC
  • Something wrong with this record ?

The importance of angle kappa evaluation for implantation of diffractive multifocal intra-ocular lenses using pseudophakic eye model

M. Karhanová, F. Pluháček, P. Mlčák, O. Vláčil, M. Šín, K. Marešová,

. 2015 ; 93 (2) : e123-8. [pub] 20140827

Language English Country England, Great Britain

Document type Comparative Study, Journal Article, Research Support, Non-U.S. Gov't

E-resources Online Full text

NLK Free Medical Journals from 2008 to 1 year ago
Medline Complete (EBSCOhost) from 2008-02-01 to 1 year ago
Wiley Free Content from 2008 to 1 year ago

PURPOSE: To determine the critical value of the angle kappa in connection with a higher risk of photic phenomena for the AcrySof ReSTOR and Tecnis multifocal intra-ocular lens (MIOL) on a standardized pseudophakic eye model. To analyse the impact of biometric value changes on the critical angle kappa. METHODS: Geometrical optic rules applied to a suitable optical model of the pseudophakic eye were used to calculate the critical value of the angle kappa for the Tecnis and three types of the AcrySof ReSTOR MIOLs. The angle kappa was defined as critical if the incident ray passed through the first ring's edge area. The influence of different positive optical corneal power (K), effective lens position (ELP) and axial length (AL) on the critical angle kappa (κc) was investigated. The dependence of κc on one of the parameters was studied for standardized values of the remaining parameters. RESULTS: The highest value of the critical angle kappa was evaluated for the Tecnis MIOL. The increase in ELP and K caused an increase in κc under the given conditions. On the contrary, an increase in AL led to lower values of κc. CONCLUSION: We demonstrated the dependence of the critical angle kappa on the central part of the MIOL and on biometric parameters of the eye, especially on the effective lens position. According to these results, we conclude that shallow anterior chamber depth in connection with a higher angle kappa is an important risk factor for pronounced photic phenomena after implantation of a diffractive MIOL.

References provided by Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc15031893
003      
CZ-PrNML
005      
20151007103048.0
007      
ta
008      
151005s2015 enk f 000 0|eng||
009      
AR
024    7_
$a 10.1111/aos.12521 $2 doi
035    __
$a (PubMed)25160117
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a enk
100    1_
$a Karhanová, Marta $u Department of Ophthalmology, Olomouc University Hospital and Faculty of Medicine and Dentistry, Palacky University, Olomouc, Czech Republic.
245    14
$a The importance of angle kappa evaluation for implantation of diffractive multifocal intra-ocular lenses using pseudophakic eye model / $c M. Karhanová, F. Pluháček, P. Mlčák, O. Vláčil, M. Šín, K. Marešová,
520    9_
$a PURPOSE: To determine the critical value of the angle kappa in connection with a higher risk of photic phenomena for the AcrySof ReSTOR and Tecnis multifocal intra-ocular lens (MIOL) on a standardized pseudophakic eye model. To analyse the impact of biometric value changes on the critical angle kappa. METHODS: Geometrical optic rules applied to a suitable optical model of the pseudophakic eye were used to calculate the critical value of the angle kappa for the Tecnis and three types of the AcrySof ReSTOR MIOLs. The angle kappa was defined as critical if the incident ray passed through the first ring's edge area. The influence of different positive optical corneal power (K), effective lens position (ELP) and axial length (AL) on the critical angle kappa (κc) was investigated. The dependence of κc on one of the parameters was studied for standardized values of the remaining parameters. RESULTS: The highest value of the critical angle kappa was evaluated for the Tecnis MIOL. The increase in ELP and K caused an increase in κc under the given conditions. On the contrary, an increase in AL led to lower values of κc. CONCLUSION: We demonstrated the dependence of the critical angle kappa on the central part of the MIOL and on biometric parameters of the eye, especially on the effective lens position. According to these results, we conclude that shallow anterior chamber depth in connection with a higher angle kappa is an important risk factor for pronounced photic phenomena after implantation of a diffractive MIOL.
650    _2
$a axiální délka oka $7 D058452
650    _2
$a rohovka $x fyziologie $7 D003315
650    _2
$a lidé $7 D006801
650    12
$a implantace nitrooční čočky $7 D019654
650    12
$a nitrooční čočky $7 D007910
650    12
$a teoretické modely $7 D008962
650    12
$a optika a fotonika $7 D055095
650    _2
$a pseudofakie $x patofyziologie $7 D019591
650    _2
$a pupila $x fyziologie $7 D011680
655    _2
$a srovnávací studie $7 D003160
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Pluháček, František
700    1_
$a Mlčák, Petr
700    1_
$a Vláčil, Ondřej
700    1_
$a Šín, Martin
700    1_
$a Marešová, Klára
773    0_
$w MED00179743 $t Acta ophthalmologica $x 1755-3768 $g Roč. 93, č. 2 (2015), s. e123-8
856    41
$u https://pubmed.ncbi.nlm.nih.gov/25160117 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20151005 $b ABA008
991    __
$a 20151007103233 $b ABA008
999    __
$a ok $b bmc $g 1092769 $s 915019
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2015 $b 93 $c 2 $d e123-8 $e 20140827 $i 1755-3768 $m Acta ophthalmologica $n Acta Ophthalmol $x MED00179743
LZP    __
$a Pubmed-20151005

Find record

Citation metrics

Loading data ...

Archiving options

Loading data ...