The importance of angle kappa evaluation for implantation of diffractive multifocal intra-ocular lenses using pseudophakic eye model
M. Karhanová, F. Pluháček, P. Mlčák, O. Vláčil, M. Šín, K. Marešová,
Language English Country England, Great Britain
Document type Comparative Study, Journal Article, Research Support, Non-U.S. Gov't
NLK
Free Medical Journals
from 2008 to 1 year ago
Medline Complete (EBSCOhost)
from 2008-02-01 to 1 year ago
Wiley Free Content
from 2008 to 1 year ago
PubMed
25160117
DOI
10.1111/aos.12521
Knihovny.cz E-resources
- MeSH
- Axial Length, Eye MeSH
- Lens Implantation, Intraocular * MeSH
- Humans MeSH
- Lenses, Intraocular * MeSH
- Optics and Photonics * MeSH
- Pseudophakia physiopathology MeSH
- Pupil physiology MeSH
- Cornea physiology MeSH
- Models, Theoretical * MeSH
- Check Tag
- Humans MeSH
- Publication type
- Journal Article MeSH
- Research Support, Non-U.S. Gov't MeSH
- Comparative Study MeSH
PURPOSE: To determine the critical value of the angle kappa in connection with a higher risk of photic phenomena for the AcrySof ReSTOR and Tecnis multifocal intra-ocular lens (MIOL) on a standardized pseudophakic eye model. To analyse the impact of biometric value changes on the critical angle kappa. METHODS: Geometrical optic rules applied to a suitable optical model of the pseudophakic eye were used to calculate the critical value of the angle kappa for the Tecnis and three types of the AcrySof ReSTOR MIOLs. The angle kappa was defined as critical if the incident ray passed through the first ring's edge area. The influence of different positive optical corneal power (K), effective lens position (ELP) and axial length (AL) on the critical angle kappa (κc) was investigated. The dependence of κc on one of the parameters was studied for standardized values of the remaining parameters. RESULTS: The highest value of the critical angle kappa was evaluated for the Tecnis MIOL. The increase in ELP and K caused an increase in κc under the given conditions. On the contrary, an increase in AL led to lower values of κc. CONCLUSION: We demonstrated the dependence of the critical angle kappa on the central part of the MIOL and on biometric parameters of the eye, especially on the effective lens position. According to these results, we conclude that shallow anterior chamber depth in connection with a higher angle kappa is an important risk factor for pronounced photic phenomena after implantation of a diffractive MIOL.
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc15031893
- 003
- CZ-PrNML
- 005
- 20151007103048.0
- 007
- ta
- 008
- 151005s2015 enk f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1111/aos.12521 $2 doi
- 035 __
- $a (PubMed)25160117
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a enk
- 100 1_
- $a Karhanová, Marta $u Department of Ophthalmology, Olomouc University Hospital and Faculty of Medicine and Dentistry, Palacky University, Olomouc, Czech Republic.
- 245 14
- $a The importance of angle kappa evaluation for implantation of diffractive multifocal intra-ocular lenses using pseudophakic eye model / $c M. Karhanová, F. Pluháček, P. Mlčák, O. Vláčil, M. Šín, K. Marešová,
- 520 9_
- $a PURPOSE: To determine the critical value of the angle kappa in connection with a higher risk of photic phenomena for the AcrySof ReSTOR and Tecnis multifocal intra-ocular lens (MIOL) on a standardized pseudophakic eye model. To analyse the impact of biometric value changes on the critical angle kappa. METHODS: Geometrical optic rules applied to a suitable optical model of the pseudophakic eye were used to calculate the critical value of the angle kappa for the Tecnis and three types of the AcrySof ReSTOR MIOLs. The angle kappa was defined as critical if the incident ray passed through the first ring's edge area. The influence of different positive optical corneal power (K), effective lens position (ELP) and axial length (AL) on the critical angle kappa (κc) was investigated. The dependence of κc on one of the parameters was studied for standardized values of the remaining parameters. RESULTS: The highest value of the critical angle kappa was evaluated for the Tecnis MIOL. The increase in ELP and K caused an increase in κc under the given conditions. On the contrary, an increase in AL led to lower values of κc. CONCLUSION: We demonstrated the dependence of the critical angle kappa on the central part of the MIOL and on biometric parameters of the eye, especially on the effective lens position. According to these results, we conclude that shallow anterior chamber depth in connection with a higher angle kappa is an important risk factor for pronounced photic phenomena after implantation of a diffractive MIOL.
- 650 _2
- $a axiální délka oka $7 D058452
- 650 _2
- $a rohovka $x fyziologie $7 D003315
- 650 _2
- $a lidé $7 D006801
- 650 12
- $a implantace nitrooční čočky $7 D019654
- 650 12
- $a nitrooční čočky $7 D007910
- 650 12
- $a teoretické modely $7 D008962
- 650 12
- $a optika a fotonika $7 D055095
- 650 _2
- $a pseudofakie $x patofyziologie $7 D019591
- 650 _2
- $a pupila $x fyziologie $7 D011680
- 655 _2
- $a srovnávací studie $7 D003160
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Pluháček, František
- 700 1_
- $a Mlčák, Petr
- 700 1_
- $a Vláčil, Ondřej
- 700 1_
- $a Šín, Martin
- 700 1_
- $a Marešová, Klára
- 773 0_
- $w MED00179743 $t Acta ophthalmologica $x 1755-3768 $g Roč. 93, č. 2 (2015), s. e123-8
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/25160117 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20151005 $b ABA008
- 991 __
- $a 20151007103233 $b ABA008
- 999 __
- $a ok $b bmc $g 1092769 $s 915019
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2015 $b 93 $c 2 $d e123-8 $e 20140827 $i 1755-3768 $m Acta ophthalmologica $n Acta Ophthalmol $x MED00179743
- LZP __
- $a Pubmed-20151005