-
Something wrong with this record ?
Quality assessment program for EuroFlow protocols: summary results of four-year (2010-2013) quality assurance rounds
T. Kalina, J. Flores-Montero, Q. Lecrevisse, CE. Pedreira, VH. van der Velden, M. Novakova, E. Mejstrikova, O. Hrusak, S. Böttcher, D. Karsch, Ł. Sędek, A. Trinquand, N. Boeckx, J. Caetano, V. Asnafi, P. Lucio, M. Lima, A. Helena Santos, P....
Language English Country United States
Document type Journal Article
Grant support
NT12425
MZ0
CEP Register
NT14534
MZ0
CEP Register
Digital library NLK
Full text - Article
Source
NLK
Free Medical Journals
from 2003 to 1 year ago
Medline Complete (EBSCOhost)
from 2012-06-01 to 1 year ago
Wiley Free Content
from 2003 to 1 year ago
PubMed
25345353
DOI
10.1002/cyto.a.22581
Knihovny.cz E-resources
- MeSH
- Immunophenotyping methods MeSH
- Leukemia classification diagnosis MeSH
- Lymphoma classification diagnosis MeSH
- Lymphocyte Subsets immunology MeSH
- Flow Cytometry methods MeSH
- Reference Values MeSH
- Reference Standards MeSH
- Quality Control MeSH
- Healthy Volunteers MeSH
- Publication type
- Journal Article MeSH
- Geographicals
- Europe MeSH
Flow cytometric immunophenotyping has become essential for accurate diagnosis, classification, and disease monitoring in hemato-oncology. The EuroFlow Consortium has established a fully standardized "all-in-one" pipeline consisting of standardized instrument settings, reagent panels, and sample preparation protocols and software for data analysis and disease classification. For its reproducible implementation, parallel development of a quality assurance (QA) program was required. Here, we report on the results of four consecutive annual rounds of the novel external QA EuroFlow program. The novel QA scheme aimed at monitoring the whole flow cytometric analysis process (cytometer setting, sample preparation, acquisition and analysis) by reading the median fluorescence intensities (MedFI) of defined lymphocytes' subsets. Each QA participant applied the predefined reagents' panel on blood cells of local healthy donors. A uniform gating strategy was applied to define lymphocyte subsets and to read MedFI values per marker. The MedFI values were compared with reference data and deviations from reference values were quantified using performance score metrics. In four annual QA rounds, we analyzed 123 blood samples from local healthy donors on 14 different instruments in 11 laboratories from nine European countries. The immunophenotype of defined cellular subsets appeared sufficiently standardized to permit unified (software) data analysis. The coefficient of variation of MedFI for 7 of 11 markers performed repeatedly below 30%, average MedFI in each QA round ranged from 86 to 125% from overall median. Calculation of performance scores was instrumental to pinpoint standardization failures and their causes. Overall, the new EuroFlow QA system for the first time allowed to quantify the technical variation that is introduced in the measurement of fluorescence intensities in a multicentric setting over an extended period of time. EuroFlow QA is a proficiency test specific for laboratories that use standardized EuroFlow protocols. It may be used to complement, but not replace, established proficiency tests. © 2014 International Society for Advancement of Cytometry.
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc16000569
- 003
- CZ-PrNML
- 005
- 20250108120648.0
- 007
- ta
- 008
- 160108s2015 xxu f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1002/cyto.a.22581 $2 doi
- 035 __
- $a (PubMed)25345353
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xxu
- 100 1_
- $a Kalina, Tomáš, $u CLIP - Childhood Leukemia Investigation Prague and Department of Pediatric Hematology and Oncology, 2nd Faculty of Medicine, Charles University Prague and University Hospital Motol, Prague, Czech Republic. $d 1975 říjen 11.- $7 xx0060125
- 245 10
- $a Quality assessment program for EuroFlow protocols: summary results of four-year (2010-2013) quality assurance rounds / $c T. Kalina, J. Flores-Montero, Q. Lecrevisse, CE. Pedreira, VH. van der Velden, M. Novakova, E. Mejstrikova, O. Hrusak, S. Böttcher, D. Karsch, Ł. Sędek, A. Trinquand, N. Boeckx, J. Caetano, V. Asnafi, P. Lucio, M. Lima, A. Helena Santos, P. Bonaccorso, AJ. van der Sluijs-Gelling, AW. Langerak, M. Martin-Ayuso, T. Szczepański, JJ. van Dongen, A. Orfao,
- 520 9_
- $a Flow cytometric immunophenotyping has become essential for accurate diagnosis, classification, and disease monitoring in hemato-oncology. The EuroFlow Consortium has established a fully standardized "all-in-one" pipeline consisting of standardized instrument settings, reagent panels, and sample preparation protocols and software for data analysis and disease classification. For its reproducible implementation, parallel development of a quality assurance (QA) program was required. Here, we report on the results of four consecutive annual rounds of the novel external QA EuroFlow program. The novel QA scheme aimed at monitoring the whole flow cytometric analysis process (cytometer setting, sample preparation, acquisition and analysis) by reading the median fluorescence intensities (MedFI) of defined lymphocytes' subsets. Each QA participant applied the predefined reagents' panel on blood cells of local healthy donors. A uniform gating strategy was applied to define lymphocyte subsets and to read MedFI values per marker. The MedFI values were compared with reference data and deviations from reference values were quantified using performance score metrics. In four annual QA rounds, we analyzed 123 blood samples from local healthy donors on 14 different instruments in 11 laboratories from nine European countries. The immunophenotype of defined cellular subsets appeared sufficiently standardized to permit unified (software) data analysis. The coefficient of variation of MedFI for 7 of 11 markers performed repeatedly below 30%, average MedFI in each QA round ranged from 86 to 125% from overall median. Calculation of performance scores was instrumental to pinpoint standardization failures and their causes. Overall, the new EuroFlow QA system for the first time allowed to quantify the technical variation that is introduced in the measurement of fluorescence intensities in a multicentric setting over an extended period of time. EuroFlow QA is a proficiency test specific for laboratories that use standardized EuroFlow protocols. It may be used to complement, but not replace, established proficiency tests. © 2014 International Society for Advancement of Cytometry.
- 650 _2
- $a průtoková cytometrie $x metody $7 D005434
- 650 _2
- $a zdraví dobrovolníci pro lékařské studie $7 D064368
- 650 _2
- $a imunofenotypizace $x metody $7 D016130
- 650 _2
- $a leukemie $x klasifikace $x diagnóza $7 D007938
- 650 _2
- $a podskupiny lymfocytů $x imunologie $7 D016131
- 650 _2
- $a lymfom $x klasifikace $x diagnóza $7 D008223
- 650 _2
- $a řízení kvality $7 D011786
- 650 _2
- $a referenční standardy $7 D012015
- 650 _2
- $a referenční hodnoty $7 D012016
- 651 _2
- $a Evropa $7 D005060
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Flores-Montero, Juan
- 700 1_
- $a Lecrevisse, Quentin
- 700 1_
- $a Pedreira, Carlos E
- 700 1_
- $a van der Velden, Vincent H J
- 700 1_
- $a Nováková, Michaela $7 xx0211356
- 700 1_
- $a Mejstříková, Ester, $d 1977- $7 xx0105223
- 700 1_
- $a Hrušák, Ondřej, $d 1965- $7 xx0036691
- 700 1_
- $a Böttcher, Sebastian, $d 1971- $7 xx0327357
- 700 1_
- $a Karsch, Dennis
- 700 1_
- $a Sędek, Łukasz
- 700 1_
- $a Trinquand, Amelie
- 700 1_
- $a Boeckx, Nancy
- 700 1_
- $a Caetano, Joana
- 700 1_
- $a Asnafi, Vahid $7 gn_A_00009464
- 700 1_
- $a Lucio, Paulo
- 700 1_
- $a Lima, Margarida
- 700 1_
- $a Helena Santos, Ana
- 700 1_
- $a Bonaccorso, Paola
- 700 1_
- $a van der Sluijs-Gelling, Alita J
- 700 1_
- $a Langerak, Anton W
- 700 1_
- $a Martin-Ayuso, Marta
- 700 1_
- $a Szczepański, Tomasz
- 700 1_
- $a van Dongen, Jacques J M
- 700 1_
- $a Orfao, Alberto
- 773 0_
- $w MED00013935 $t Cytometry. Part A $x 1552-4930 $g Roč. 87, č. 2 (2015), s. 145-156
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/25345353 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20160108 $b ABA008
- 991 __
- $a 20250108120644 $b ABA008
- 999 __
- $a ok $b bmc $g 1102850 $s 924775
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2015 $b 87 $c 2 $d 145-156 $e 20141023 $i 1552-4930 $m Cytometry. Part A $n Cytometry A $x MED00013935
- GRA __
- $a NT12425 $p MZ0
- GRA __
- $a NT14534 $p MZ0
- LZP __
- $a Pubmed-20160108