Attenuation of X and Gamma Rays in Personal Radiation Shielding Protective Clothing

M. Kozlovska, R. Cerny, P. Otahal,

. 2015 ; 109 (3 Suppl 3) : S205-11.

Jazyk angličtina Země Spojené státy americké

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc16009943

A collection of personal radiation shielding protective clothing, suitable for use in case of accidents in nuclear facilities or radiological emergency situations involving radioactive agents, was gathered and tested at the Nuclear Protection Department of the National Institute for Nuclear, Chemical and Biological Protection, Czech Republic. Attenuating qualities of shielding layers in individual protective clothing were tested via spectra measurement of x and gamma rays, penetrating them. The rays originated from different radionuclide point sources, the gamma ray energies of which cover a broad energy range. The spectra were measured by handheld spectrometers, both scintillation and High Purity Germanium. Different narrow beam geometries were adjusted using a special testing bench and a set of various collimators. The main experimentally determined quantity for individual samples of personal radiation shielding protective clothing was x and gamma rays attenuation for significant energies of the spectra. The attenuation was assessed comparing net peak areas (after background subtraction) in spectra, where a tested sample was placed between the source and the detector, and corresponding net peak areas in spectra, measured without the sample. Mass attenuation coefficients, which describe attenuating qualities of shielding layers materials in individual samples, together with corresponding lead equivalents, were determined as well. Experimentally assessed mass attenuation coefficients of the samples were compared to the referred ones for individual heavy metals.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc16009943
003      
CZ-PrNML
005      
20160414102320.0
007      
ta
008      
160408s2015 xxu f 000 0|eng||
009      
AR
024    7_
$a 10.1097/HP.0000000000000361 $2 doi
024    7_
$a 10.1097/HP.0000000000000361 $2 doi
035    __
$a (PubMed)26425983
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xxu
100    1_
$a Kozlovska, Michaela $u * National Institute for NBC Protection (SUJCHBO v.v.i.), Nuclear Protection Department, Kamenna 71, 262 31 Milin, Czech Republic.
245    10
$a Attenuation of X and Gamma Rays in Personal Radiation Shielding Protective Clothing / $c M. Kozlovska, R. Cerny, P. Otahal,
520    9_
$a A collection of personal radiation shielding protective clothing, suitable for use in case of accidents in nuclear facilities or radiological emergency situations involving radioactive agents, was gathered and tested at the Nuclear Protection Department of the National Institute for Nuclear, Chemical and Biological Protection, Czech Republic. Attenuating qualities of shielding layers in individual protective clothing were tested via spectra measurement of x and gamma rays, penetrating them. The rays originated from different radionuclide point sources, the gamma ray energies of which cover a broad energy range. The spectra were measured by handheld spectrometers, both scintillation and High Purity Germanium. Different narrow beam geometries were adjusted using a special testing bench and a set of various collimators. The main experimentally determined quantity for individual samples of personal radiation shielding protective clothing was x and gamma rays attenuation for significant energies of the spectra. The attenuation was assessed comparing net peak areas (after background subtraction) in spectra, where a tested sample was placed between the source and the detector, and corresponding net peak areas in spectra, measured without the sample. Mass attenuation coefficients, which describe attenuating qualities of shielding layers materials in individual samples, together with corresponding lead equivalents, were determined as well. Experimentally assessed mass attenuation coefficients of the samples were compared to the referred ones for individual heavy metals.
650    _2
$a plánování postupu v případě katastrof $x metody $7 D004189
650    12
$a first responder $7 D060731
650    _2
$a záření gama $7 D005720
650    _2
$a germanium $7 D005857
650    _2
$a lidé $7 D006801
650    _2
$a těžké kovy $7 D019216
650    _2
$a fotony $7 D017785
650    12
$a ochranné oděvy $7 D011481
650    _2
$a dávka záření $7 D011829
650    _2
$a radiační poranění $x prevence a kontrola $7 D011832
650    _2
$a radiační ochrana $x metody $7 D011835
650    12
$a únik radioaktivních látek $7 D018788
650    _2
$a software $7 D012984
650    _2
$a rentgenové záření $7 D014965
655    _2
$a časopisecké články $7 D016428
700    1_
$a Cerny, Radek
700    1_
$a Otahal, Petr
773    0_
$w MED00001994 $t Health physics $x 1538-5159 $g Roč. 109, č. 3 Suppl 3 (2015), s. S205-11
856    41
$u https://pubmed.ncbi.nlm.nih.gov/26425983 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20160408 $b ABA008
991    __
$a 20160414102404 $b ABA008
999    __
$a ok $b bmc $g 1113372 $s 934311
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2015 $b 109 $c 3 Suppl 3 $d S205-11 $i 1538-5159 $m Health physics $n Health Phys $x MED00001994
LZP    __
$a Pubmed-20160408

Najít záznam

Citační ukazatele

Pouze přihlášení uživatelé

Možnosti archivace

Nahrávání dat ...