Attenuation of X and Gamma Rays in Personal Radiation Shielding Protective Clothing
M. Kozlovska, R. Cerny, P. Otahal,
Jazyk angličtina Země Spojené státy americké
Typ dokumentu časopisecké články
- MeSH
- dávka záření MeSH
- first responder * MeSH
- fotony MeSH
- germanium MeSH
- lidé MeSH
- ochranné oděvy * MeSH
- plánování postupu v případě katastrof metody MeSH
- radiační ochrana metody MeSH
- radiační poranění prevence a kontrola MeSH
- rentgenové záření MeSH
- software MeSH
- těžké kovy MeSH
- únik radioaktivních látek * MeSH
- záření gama MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
A collection of personal radiation shielding protective clothing, suitable for use in case of accidents in nuclear facilities or radiological emergency situations involving radioactive agents, was gathered and tested at the Nuclear Protection Department of the National Institute for Nuclear, Chemical and Biological Protection, Czech Republic. Attenuating qualities of shielding layers in individual protective clothing were tested via spectra measurement of x and gamma rays, penetrating them. The rays originated from different radionuclide point sources, the gamma ray energies of which cover a broad energy range. The spectra were measured by handheld spectrometers, both scintillation and High Purity Germanium. Different narrow beam geometries were adjusted using a special testing bench and a set of various collimators. The main experimentally determined quantity for individual samples of personal radiation shielding protective clothing was x and gamma rays attenuation for significant energies of the spectra. The attenuation was assessed comparing net peak areas (after background subtraction) in spectra, where a tested sample was placed between the source and the detector, and corresponding net peak areas in spectra, measured without the sample. Mass attenuation coefficients, which describe attenuating qualities of shielding layers materials in individual samples, together with corresponding lead equivalents, were determined as well. Experimentally assessed mass attenuation coefficients of the samples were compared to the referred ones for individual heavy metals.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc16009943
- 003
- CZ-PrNML
- 005
- 20160414102320.0
- 007
- ta
- 008
- 160408s2015 xxu f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1097/HP.0000000000000361 $2 doi
- 024 7_
- $a 10.1097/HP.0000000000000361 $2 doi
- 035 __
- $a (PubMed)26425983
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xxu
- 100 1_
- $a Kozlovska, Michaela $u * National Institute for NBC Protection (SUJCHBO v.v.i.), Nuclear Protection Department, Kamenna 71, 262 31 Milin, Czech Republic.
- 245 10
- $a Attenuation of X and Gamma Rays in Personal Radiation Shielding Protective Clothing / $c M. Kozlovska, R. Cerny, P. Otahal,
- 520 9_
- $a A collection of personal radiation shielding protective clothing, suitable for use in case of accidents in nuclear facilities or radiological emergency situations involving radioactive agents, was gathered and tested at the Nuclear Protection Department of the National Institute for Nuclear, Chemical and Biological Protection, Czech Republic. Attenuating qualities of shielding layers in individual protective clothing were tested via spectra measurement of x and gamma rays, penetrating them. The rays originated from different radionuclide point sources, the gamma ray energies of which cover a broad energy range. The spectra were measured by handheld spectrometers, both scintillation and High Purity Germanium. Different narrow beam geometries were adjusted using a special testing bench and a set of various collimators. The main experimentally determined quantity for individual samples of personal radiation shielding protective clothing was x and gamma rays attenuation for significant energies of the spectra. The attenuation was assessed comparing net peak areas (after background subtraction) in spectra, where a tested sample was placed between the source and the detector, and corresponding net peak areas in spectra, measured without the sample. Mass attenuation coefficients, which describe attenuating qualities of shielding layers materials in individual samples, together with corresponding lead equivalents, were determined as well. Experimentally assessed mass attenuation coefficients of the samples were compared to the referred ones for individual heavy metals.
- 650 _2
- $a plánování postupu v případě katastrof $x metody $7 D004189
- 650 12
- $a first responder $7 D060731
- 650 _2
- $a záření gama $7 D005720
- 650 _2
- $a germanium $7 D005857
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a těžké kovy $7 D019216
- 650 _2
- $a fotony $7 D017785
- 650 12
- $a ochranné oděvy $7 D011481
- 650 _2
- $a dávka záření $7 D011829
- 650 _2
- $a radiační poranění $x prevence a kontrola $7 D011832
- 650 _2
- $a radiační ochrana $x metody $7 D011835
- 650 12
- $a únik radioaktivních látek $7 D018788
- 650 _2
- $a software $7 D012984
- 650 _2
- $a rentgenové záření $7 D014965
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Cerny, Radek
- 700 1_
- $a Otahal, Petr
- 773 0_
- $w MED00001994 $t Health physics $x 1538-5159 $g Roč. 109, č. 3 Suppl 3 (2015), s. S205-11
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/26425983 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20160408 $b ABA008
- 991 __
- $a 20160414102404 $b ABA008
- 999 __
- $a ok $b bmc $g 1113372 $s 934311
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2015 $b 109 $c 3 Suppl 3 $d S205-11 $i 1538-5159 $m Health physics $n Health Phys $x MED00001994
- LZP __
- $a Pubmed-20160408