Detail
Článek
Článek online
FT
Medvik - BMČ
  • Je něco špatně v tomto záznamu ?

Inter-daily variability in body composition among young men

P. Kutáč,

. 2015 ; 34 (-) : 32. [pub] 20150922

Jazyk angličtina Země Anglie, Velká Británie

Typ dokumentu časopisecké články, práce podpořená grantem

Perzistentní odkaz   https://www.medvik.cz/link/bmc16009956

BACKGROUND: The present study analyses changes in body composition over the course of a working week. The purpose of the study is to identify the size of the changes in the observed parameters by means of typical error of measurement (TE) as the initial value for the interpretation of the detected changes in the repeated measurement in diagnostic practice. METHODS: The researched group consisted of 86 males, aged 21.4 ± 1.0 years. All the participants were free of any medical conditions. The measurement of each participant took place over 1 week from Monday till Friday, in the morning hours. Parameters measured: body mass (BM), total body water (TBW), and body fat (BF). The measurement employed two devices using the bioelectric impedance analysis. These devices were the analyzers Tanita BC 418 MA and Nutriguard MS. In order to assess the differences between the average values, the analysis of repeated measurements was used. To assess the material significance, eta squared was used. TE was used to express the size of the changes in the observed parameters. RESULTS: A statistically significant difference between the average values of the observed parameters was only detected when using the Tanita BC 418 MA analyzer. Based on the post-hoc tests, these differences in the average values were always detected on Monday and Friday. No material significance was proved, however. The highest TE values were also detected in measurements carried out on Monday and Friday. For BM, the value of TE was 0.6 kg, for TBW 1.0-1.1%, 0.8-0.9 kg, and for BF 1.2-1.6%, 1.1-1.3 kg depending on the analyzer used. CONCLUSIONS: The results of the present study demonstrate the stability of parameters of body composition throughout a working week, with the provision that standard measuring conditions are fulfilled. For the purpose of diagnostic practice, when interpreting the results of the repeated measurements, it is advisable to take as provable change caused by the observed factors only the ones whose values exceed the value of a weekly TE or the upper limit of the interval of the measurement reliability.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc16009956
003      
CZ-PrNML
005      
20160520111521.0
007      
ta
008      
160408s2015 enk f 000 0|eng||
009      
AR
024    7_
$a 10.1186/s40101-015-0070-6 $2 doi
024    7_
$a 10.1186/s40101-015-0070-6 $2 doi
035    __
$a (PubMed)26395170
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a enk
100    1_
$a Kutáč, Petr $u Human Motion Diagnostics Center, University of Ostrava, Varenska 40a, Ostrava 1, 702 00, Czech Republic. petr.kutac@osu.cz.
245    10
$a Inter-daily variability in body composition among young men / $c P. Kutáč,
520    9_
$a BACKGROUND: The present study analyses changes in body composition over the course of a working week. The purpose of the study is to identify the size of the changes in the observed parameters by means of typical error of measurement (TE) as the initial value for the interpretation of the detected changes in the repeated measurement in diagnostic practice. METHODS: The researched group consisted of 86 males, aged 21.4 ± 1.0 years. All the participants were free of any medical conditions. The measurement of each participant took place over 1 week from Monday till Friday, in the morning hours. Parameters measured: body mass (BM), total body water (TBW), and body fat (BF). The measurement employed two devices using the bioelectric impedance analysis. These devices were the analyzers Tanita BC 418 MA and Nutriguard MS. In order to assess the differences between the average values, the analysis of repeated measurements was used. To assess the material significance, eta squared was used. TE was used to express the size of the changes in the observed parameters. RESULTS: A statistically significant difference between the average values of the observed parameters was only detected when using the Tanita BC 418 MA analyzer. Based on the post-hoc tests, these differences in the average values were always detected on Monday and Friday. No material significance was proved, however. The highest TE values were also detected in measurements carried out on Monday and Friday. For BM, the value of TE was 0.6 kg, for TBW 1.0-1.1%, 0.8-0.9 kg, and for BF 1.2-1.6%, 1.1-1.3 kg depending on the analyzer used. CONCLUSIONS: The results of the present study demonstrate the stability of parameters of body composition throughout a working week, with the provision that standard measuring conditions are fulfilled. For the purpose of diagnostic practice, when interpreting the results of the repeated measurements, it is advisable to take as provable change caused by the observed factors only the ones whose values exceed the value of a weekly TE or the upper limit of the interval of the measurement reliability.
650    _2
$a dospělí $7 D000328
650    _2
$a složení těla $x fyziologie $7 D001823
650    _2
$a tělesná výška $7 D001827
650    _2
$a tělesná hmotnost $7 D001835
650    _2
$a kohortové studie $7 D015331
650    _2
$a lidé $7 D006801
650    _2
$a mužské pohlaví $7 D008297
650    _2
$a reprodukovatelnost výsledků $7 D015203
650    _2
$a mladý dospělý $7 D055815
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
773    0_
$w MED00188778 $t Journal of physiological anthropology $x 1880-6805 $g Roč. 34, č. - (2015), s. 32
856    41
$u https://pubmed.ncbi.nlm.nih.gov/26395170 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20160408 $b ABA008
991    __
$a 20160520111634 $b ABA008
999    __
$a ok $b bmc $g 1113385 $s 934324
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2015 $b 34 $c - $d 32 $e 20150922 $i 1880-6805 $m Journal of physiological anthropology $n J Physiol Anthropol $x MED00188778
LZP    __
$a Pubmed-20160408

Najít záznam

Citační ukazatele

Pouze přihlášení uživatelé

Možnosti archivace

Nahrávání dat ...