On-line coupling of Micro-Extraction by Packed Sorbent with Sequential Injection Chromatography system for direct extraction and determination of betaxolol in human urine
I. Šrámková, P. Chocholouš, H. Sklenářová, D. Šatínský,
Language English Country Netherlands
Document type Journal Article, Research Support, Non-U.S. Gov't
- MeSH
- Urinalysis instrumentation methods MeSH
- Betaxolol isolation & purification urine MeSH
- Chromatography methods MeSH
- Equipment Design MeSH
- Spectrometry, Fluorescence MeSH
- Injections * MeSH
- Humans MeSH
- Solid Phase Microextraction methods MeSH
- Check Tag
- Humans MeSH
- Male MeSH
- Publication type
- Journal Article MeSH
- Research Support, Non-U.S. Gov't MeSH
A novel approach for automation of Micro-Extraction by Packed Sorbent (MEPS), a solid phase extraction technique, is presented, enabling precise and repeatable liquid handling due to the employment of sequential injection technique. The developed system was used for human urine sample clean-up and pre-concentration of betaxolol before its separation and determination. A commercial MEPS C-18 cartridge was integrated into an SIChrom™ system. The chromatographic separation was performed on a monolithic High Resolution C18 (50×4.6 mm) column which was coupled on-line in the system with Micro-Extraction using an additional selection valve. A mixture of acetonitrile and aqueous solution of 0.5% triethylamine with acetic acid, pH adjusted to 4.5 in ratio 30:70 was used as a mobile phase for elution of betaxolol from MEPS directly onto the monolithic column where the separation took place. Betaxolol was quantified by a fluorescence detector at wavelengths λ(ex)=220 nm and λ(em)=305 nm. The linear calibration range of 5-400 ng mL(-1), with limit of detection 1.5 ng mL(-1) and limit of quantification 5 ng mL(-1) and correlation r=0.9998 for both the standard and urine matrix calibration were achieved. The system recovery was 105±5%; 100±4%; 108±1% for three concentration levels of betaxolol in 10 times diluted urine - 5, 20 and 200 ng mL(-1), respectively.
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc16010100
- 003
- CZ-PrNML
- 005
- 20160418112132.0
- 007
- ta
- 008
- 160408s2015 ne f 000 0|engg|
- 009
- AR
- 024 7_
- $a 10.1016/j.talanta.2015.05.048 $2 doi
- 024 7_
- $a 10.1016/j.talanta.2015.05.048 $2 doi
- 035 __
- $a (PubMed)26078140
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a ne
- 100 1_
- $a Šrámková, Ivana $u Department of Analytical Chemistry, Faculty of Pharmacy, Charles University in Prague, Heyrovského 1203, Hradec Králové 50005, Czech Republic.
- 245 10
- $a On-line coupling of Micro-Extraction by Packed Sorbent with Sequential Injection Chromatography system for direct extraction and determination of betaxolol in human urine / $c I. Šrámková, P. Chocholouš, H. Sklenářová, D. Šatínský,
- 520 9_
- $a A novel approach for automation of Micro-Extraction by Packed Sorbent (MEPS), a solid phase extraction technique, is presented, enabling precise and repeatable liquid handling due to the employment of sequential injection technique. The developed system was used for human urine sample clean-up and pre-concentration of betaxolol before its separation and determination. A commercial MEPS C-18 cartridge was integrated into an SIChrom™ system. The chromatographic separation was performed on a monolithic High Resolution C18 (50×4.6 mm) column which was coupled on-line in the system with Micro-Extraction using an additional selection valve. A mixture of acetonitrile and aqueous solution of 0.5% triethylamine with acetic acid, pH adjusted to 4.5 in ratio 30:70 was used as a mobile phase for elution of betaxolol from MEPS directly onto the monolithic column where the separation took place. Betaxolol was quantified by a fluorescence detector at wavelengths λ(ex)=220 nm and λ(em)=305 nm. The linear calibration range of 5-400 ng mL(-1), with limit of detection 1.5 ng mL(-1) and limit of quantification 5 ng mL(-1) and correlation r=0.9998 for both the standard and urine matrix calibration were achieved. The system recovery was 105±5%; 100±4%; 108±1% for three concentration levels of betaxolol in 10 times diluted urine - 5, 20 and 200 ng mL(-1), respectively.
- 650 _2
- $a betaxolol $x izolace a purifikace $x moč $7 D015784
- 650 _2
- $a chromatografie $x metody $7 D002845
- 650 _2
- $a design vybavení $7 D004867
- 650 _2
- $a lidé $7 D006801
- 650 12
- $a injekce $7 D007267
- 650 _2
- $a mužské pohlaví $7 D008297
- 650 _2
- $a mikroextrakce na pevné fázi $x metody $7 D052617
- 650 _2
- $a fluorescenční spektrometrie $7 D013050
- 650 _2
- $a analýza moči $x přístrojové vybavení $x metody $7 D016482
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Chocholouš, Petr $u Department of Analytical Chemistry, Faculty of Pharmacy, Charles University in Prague, Heyrovského 1203, Hradec Králové 50005, Czech Republic.
- 700 1_
- $a Sklenářová, Hana $u Department of Analytical Chemistry, Faculty of Pharmacy, Charles University in Prague, Heyrovského 1203, Hradec Králové 50005, Czech Republic.
- 700 1_
- $a Šatínský, Dalibor $u Department of Analytical Chemistry, Faculty of Pharmacy, Charles University in Prague, Heyrovského 1203, Hradec Králové 50005, Czech Republic. Electronic address: satinsky@faf.cuni.cz.
- 773 0_
- $w MED00004484 $t Talanta $x 1873-3573 $g Roč. 143, č. - (2015), s. 132-7
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/26078140 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20160408 $b ABA008
- 991 __
- $a 20160418112219 $b ABA008
- 999 __
- $a ok $b bmc $g 1113529 $s 934468
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2015 $b 143 $c - $d 132-7 $e 20150522 $i 1873-3573 $m Talanta $n Talanta $x MED00004484
- LZP __
- $a Pubmed-20160408