On-line coupling of Micro-Extraction by Packed Sorbent with Sequential Injection Chromatography system for direct extraction and determination of betaxolol in human urine

I. Šrámková, P. Chocholouš, H. Sklenářová, D. Šatínský,

. 2015 ; 143 (-) : 132-7. [pub] 20150522

Jazyk angličtina Země Nizozemsko

Typ dokumentu časopisecké články, práce podpořená grantem

Perzistentní odkaz   https://www.medvik.cz/link/bmc16010100

A novel approach for automation of Micro-Extraction by Packed Sorbent (MEPS), a solid phase extraction technique, is presented, enabling precise and repeatable liquid handling due to the employment of sequential injection technique. The developed system was used for human urine sample clean-up and pre-concentration of betaxolol before its separation and determination. A commercial MEPS C-18 cartridge was integrated into an SIChrom™ system. The chromatographic separation was performed on a monolithic High Resolution C18 (50×4.6 mm) column which was coupled on-line in the system with Micro-Extraction using an additional selection valve. A mixture of acetonitrile and aqueous solution of 0.5% triethylamine with acetic acid, pH adjusted to 4.5 in ratio 30:70 was used as a mobile phase for elution of betaxolol from MEPS directly onto the monolithic column where the separation took place. Betaxolol was quantified by a fluorescence detector at wavelengths λ(ex)=220 nm and λ(em)=305 nm. The linear calibration range of 5-400 ng mL(-1), with limit of detection 1.5 ng mL(-1) and limit of quantification 5 ng mL(-1) and correlation r=0.9998 for both the standard and urine matrix calibration were achieved. The system recovery was 105±5%; 100±4%; 108±1% for three concentration levels of betaxolol in 10 times diluted urine - 5, 20 and 200 ng mL(-1), respectively.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc16010100
003      
CZ-PrNML
005      
20160418112132.0
007      
ta
008      
160408s2015 ne f 000 0|engg|
009      
AR
024    7_
$a 10.1016/j.talanta.2015.05.048 $2 doi
024    7_
$a 10.1016/j.talanta.2015.05.048 $2 doi
035    __
$a (PubMed)26078140
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a ne
100    1_
$a Šrámková, Ivana $u Department of Analytical Chemistry, Faculty of Pharmacy, Charles University in Prague, Heyrovského 1203, Hradec Králové 50005, Czech Republic.
245    10
$a On-line coupling of Micro-Extraction by Packed Sorbent with Sequential Injection Chromatography system for direct extraction and determination of betaxolol in human urine / $c I. Šrámková, P. Chocholouš, H. Sklenářová, D. Šatínský,
520    9_
$a A novel approach for automation of Micro-Extraction by Packed Sorbent (MEPS), a solid phase extraction technique, is presented, enabling precise and repeatable liquid handling due to the employment of sequential injection technique. The developed system was used for human urine sample clean-up and pre-concentration of betaxolol before its separation and determination. A commercial MEPS C-18 cartridge was integrated into an SIChrom™ system. The chromatographic separation was performed on a monolithic High Resolution C18 (50×4.6 mm) column which was coupled on-line in the system with Micro-Extraction using an additional selection valve. A mixture of acetonitrile and aqueous solution of 0.5% triethylamine with acetic acid, pH adjusted to 4.5 in ratio 30:70 was used as a mobile phase for elution of betaxolol from MEPS directly onto the monolithic column where the separation took place. Betaxolol was quantified by a fluorescence detector at wavelengths λ(ex)=220 nm and λ(em)=305 nm. The linear calibration range of 5-400 ng mL(-1), with limit of detection 1.5 ng mL(-1) and limit of quantification 5 ng mL(-1) and correlation r=0.9998 for both the standard and urine matrix calibration were achieved. The system recovery was 105±5%; 100±4%; 108±1% for three concentration levels of betaxolol in 10 times diluted urine - 5, 20 and 200 ng mL(-1), respectively.
650    _2
$a betaxolol $x izolace a purifikace $x moč $7 D015784
650    _2
$a chromatografie $x metody $7 D002845
650    _2
$a design vybavení $7 D004867
650    _2
$a lidé $7 D006801
650    12
$a injekce $7 D007267
650    _2
$a mužské pohlaví $7 D008297
650    _2
$a mikroextrakce na pevné fázi $x metody $7 D052617
650    _2
$a fluorescenční spektrometrie $7 D013050
650    _2
$a analýza moči $x přístrojové vybavení $x metody $7 D016482
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Chocholouš, Petr $u Department of Analytical Chemistry, Faculty of Pharmacy, Charles University in Prague, Heyrovského 1203, Hradec Králové 50005, Czech Republic.
700    1_
$a Sklenářová, Hana $u Department of Analytical Chemistry, Faculty of Pharmacy, Charles University in Prague, Heyrovského 1203, Hradec Králové 50005, Czech Republic.
700    1_
$a Šatínský, Dalibor $u Department of Analytical Chemistry, Faculty of Pharmacy, Charles University in Prague, Heyrovského 1203, Hradec Králové 50005, Czech Republic. Electronic address: satinsky@faf.cuni.cz.
773    0_
$w MED00004484 $t Talanta $x 1873-3573 $g Roč. 143, č. - (2015), s. 132-7
856    41
$u https://pubmed.ncbi.nlm.nih.gov/26078140 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20160408 $b ABA008
991    __
$a 20160418112219 $b ABA008
999    __
$a ok $b bmc $g 1113529 $s 934468
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2015 $b 143 $c - $d 132-7 $e 20150522 $i 1873-3573 $m Talanta $n Talanta $x MED00004484
LZP    __
$a Pubmed-20160408

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...