-
Je něco špatně v tomto záznamu ?
Durability of Pulmonary Vein Isolation with Cryoballoon Ablation: Results from the Sustained PV Isolation with Arctic Front Advance (SUPIR) Study
VY. Reddy, L. Sediva, J. Petru, J. Skoda, M. Chovanec, Z. Chitovova, P. Di Stefano, E. Rubin, S. Dukkipati, P. Neuzil,
Jazyk angličtina Země Spojené státy americké
Typ dokumentu klinické zkoušky, časopisecké články, práce podpořená grantem
NLK
CINAHL Plus with Full Text (EBSCOhost)
od 1990-02-01 do Před 1 rokem
Medline Complete (EBSCOhost)
od 1990-02-01 do Před 1 rokem
PubMed
25644659
DOI
10.1111/jce.12626
Knihovny.cz E-zdroje
- MeSH
- akční potenciály MeSH
- časové faktory MeSH
- design vybavení MeSH
- elektrofyziologické techniky kardiologické MeSH
- ezofágoskopie MeSH
- fibrilace síní diagnóza patofyziologie chirurgie MeSH
- kryochirurgie škodlivé účinky přístrojové vybavení MeSH
- lidé středního věku MeSH
- lidé MeSH
- nerandomizované kontrolované studie jako téma MeSH
- prospektivní studie MeSH
- recidiva MeSH
- senioři MeSH
- srdeční katétry * MeSH
- venae pulmonales patofyziologie chirurgie MeSH
- výsledek terapie MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- klinické zkoušky MeSH
- práce podpořená grantem MeSH
- Geografické názvy
- Česká republika MeSH
INTRODUCTION: Pulmonary vein (PV) reconnection remains the most important cause of AF recurrence after AF ablation. The second-generation cryoballoon catheter's ability to achieve durable PV isolation was assessed in a prospective nonrandomized clinical trial. METHODS AND RESULTS: PV isolation was performed by 4-minute ablations. Following verification of electrical isolation by a multielectrode mapping catheter, 1 additional lesion per PV was applied. Esophageal temperatures were monitored and all patients underwent postprocedure esophageal endoscopy. All patients underwent a second PV remapping procedure at ∼3 months to assess for PVI durability. Eighty-four (100%) veins were acutely isolated using only the 28 mm cryoballoon in 21 consecutive PAF patients with 2.2 ± 0.6 cryoapplications per vein, with the majority (83%) occurring after a single freeze. One patient presented with hematemesis and an esophageal ulceration that was treated conservatively; there were no episodes of esophageal fistula or phrenic nerve palsy. At 3.4 (2.9-4.1) months postablation, 68/75 veins (91%) remained electrically isolated; all PVs remained durably isolated in 79% of patients. Two patients accounted for 5 of 7 reconducting veins. The most common site for reconnection was the inferior aspect of the RIPV (3/7 reconnections). Reconnected veins had poorer occlusion at the index ablation procedure than veins that maintained chronic isolation (occlusion grade 2.9 ± 0.7 vs. 3.4 ± 0.7, P = 0.001). Clinical AF recurrence was detected in 2 patients (11%) at follow-up. CONCLUSIONS: The improved thermodynamic characteristics of the second-generation cryoballoon led to a high rate of both single-shot PVI and chronic lesion durability. This high rate of durable PV isolation is anticipated to translate to improved clinical outcome.
Cardiac Arrhythmia Service of the Mt Sinai Hospital New York New York USA
EMEA Regional Clinical Center Medtronic Clinical Research Institute Milan Italy
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc16010590
- 003
- CZ-PrNML
- 005
- 20160414121308.0
- 007
- ta
- 008
- 160408s2015 xxu f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1111/jce.12626 $2 doi
- 024 7_
- $a 10.1111/jce.12626 $2 doi
- 035 __
- $a (PubMed)25644659
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xxu
- 100 1_
- $a Reddy, Vivek Y $u Cardiac Arrhythmia Service of the Mt. Sinai Hospital, New York, New York, USA.
- 245 10
- $a Durability of Pulmonary Vein Isolation with Cryoballoon Ablation: Results from the Sustained PV Isolation with Arctic Front Advance (SUPIR) Study / $c VY. Reddy, L. Sediva, J. Petru, J. Skoda, M. Chovanec, Z. Chitovova, P. Di Stefano, E. Rubin, S. Dukkipati, P. Neuzil,
- 520 9_
- $a INTRODUCTION: Pulmonary vein (PV) reconnection remains the most important cause of AF recurrence after AF ablation. The second-generation cryoballoon catheter's ability to achieve durable PV isolation was assessed in a prospective nonrandomized clinical trial. METHODS AND RESULTS: PV isolation was performed by 4-minute ablations. Following verification of electrical isolation by a multielectrode mapping catheter, 1 additional lesion per PV was applied. Esophageal temperatures were monitored and all patients underwent postprocedure esophageal endoscopy. All patients underwent a second PV remapping procedure at ∼3 months to assess for PVI durability. Eighty-four (100%) veins were acutely isolated using only the 28 mm cryoballoon in 21 consecutive PAF patients with 2.2 ± 0.6 cryoapplications per vein, with the majority (83%) occurring after a single freeze. One patient presented with hematemesis and an esophageal ulceration that was treated conservatively; there were no episodes of esophageal fistula or phrenic nerve palsy. At 3.4 (2.9-4.1) months postablation, 68/75 veins (91%) remained electrically isolated; all PVs remained durably isolated in 79% of patients. Two patients accounted for 5 of 7 reconducting veins. The most common site for reconnection was the inferior aspect of the RIPV (3/7 reconnections). Reconnected veins had poorer occlusion at the index ablation procedure than veins that maintained chronic isolation (occlusion grade 2.9 ± 0.7 vs. 3.4 ± 0.7, P = 0.001). Clinical AF recurrence was detected in 2 patients (11%) at follow-up. CONCLUSIONS: The improved thermodynamic characteristics of the second-generation cryoballoon led to a high rate of both single-shot PVI and chronic lesion durability. This high rate of durable PV isolation is anticipated to translate to improved clinical outcome.
- 650 _2
- $a akční potenciály $7 D000200
- 650 _2
- $a senioři $7 D000368
- 650 _2
- $a fibrilace síní $x diagnóza $x patofyziologie $x chirurgie $7 D001281
- 650 12
- $a srdeční katétry $7 D062906
- 650 _2
- $a kryochirurgie $x škodlivé účinky $x přístrojové vybavení $7 D003452
- 650 _2
- $a elektrofyziologické techniky kardiologické $7 D022062
- 650 _2
- $a design vybavení $7 D004867
- 650 _2
- $a ezofágoskopie $7 D004945
- 650 _2
- $a ženské pohlaví $7 D005260
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a mužské pohlaví $7 D008297
- 650 _2
- $a lidé středního věku $7 D008875
- 650 _2
- $a nerandomizované kontrolované studie jako téma $7 D065228
- 650 _2
- $a prospektivní studie $7 D011446
- 650 _2
- $a venae pulmonales $x patofyziologie $x chirurgie $7 D011667
- 650 _2
- $a recidiva $7 D012008
- 650 _2
- $a časové faktory $7 D013997
- 650 _2
- $a výsledek terapie $7 D016896
- 651 _2
- $a Česká republika $7 D018153
- 655 _2
- $a klinické zkoušky $7 D016430
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Sediva, Lucie $u Homolka Hospital, Prague, Czech Republic.
- 700 1_
- $a Petru, Jan $u Homolka Hospital, Prague, Czech Republic.
- 700 1_
- $a Skoda, Jan $u Homolka Hospital, Prague, Czech Republic.
- 700 1_
- $a Chovanec, Milan $u Homolka Hospital, Prague, Czech Republic.
- 700 1_
- $a Chitovova, Zita $u Homolka Hospital, Prague, Czech Republic.
- 700 1_
- $a Di Stefano, Paola $u EMEA Regional Clinical Center, Medtronic Clinical Research Institute, Milan, Italy.
- 700 1_
- $a Rubin, Ethel $u Medtronic Inc., Minneapolis, Minnesota, USA.
- 700 1_
- $a Dukkipati, Srinivas $u Cardiac Arrhythmia Service of the Mt. Sinai Hospital, New York, New York, USA.
- 700 1_
- $a Neuzil, Petr $u Homolka Hospital, Prague, Czech Republic.
- 773 0_
- $w MED00002569 $t Journal of cardiovascular electrophysiology $x 1540-8167 $g Roč. 26, č. 5 (2015), s. 493-500
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/25644659 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20160408 $b ABA008
- 991 __
- $a 20160414121352 $b ABA008
- 999 __
- $a ok $b bmc $g 1114019 $s 934958
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2015 $b 26 $c 5 $d 493-500 $e 20150415 $i 1540-8167 $m Journal of cardiovascular electrophysiology $n J Cardiovasc Electrophysiol $x MED00002569
- LZP __
- $a Pubmed-20160408