• Something wrong with this record ?

A modular Geant4 model of Leksell Gamma Knife Perfexion™

J. Pipek, J. Novotný, J. Novotný, P. Kozubíková,

. 2014 ; 59 (24) : 7609-23.

Language English Country England, Great Britain

Document type Journal Article, Research Support, Non-U.S. Gov't

This work presents a Monte Carlo model of Leksell Gamma Knife Perfexion as well as the main parameters of the dose distribution in the standard phantom obtained using this model. The model is developed in the Geant4 simulation toolkit in a modular way which enables its reuse in other Perfexion studies. Large phase space files were created, containing particles that are entering the inner machine cavity after being transported through the collimation system. All 14 output factors of the machine and effective output factors for both the 4 mm (0.830 ± 0.009) and 8 mm (0.921 ± 0.004) collimators were calculated. Dose profiles along the main axes are also included for each collimator size. All results are compared to the values obtained from the treatment planning system, from experiments, and from other Monte Carlo models.

References provided by Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc16010694
003      
CZ-PrNML
005      
20160418100437.0
007      
ta
008      
160408s2014 enk f 000 0|eng||
009      
AR
024    7_
$a 10.1088/0031-9155/59/24/7609 $2 doi
024    7_
$a 10.1088/0031-9155/59/24/7609 $2 doi
035    __
$a (PubMed)25415510
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a enk
100    1_
$a Pipek, J $u Czech Technical University in Prague, Faculty of Nuclear Sciences and Physical Engineering, Břehová 7, 115 19 Prague 1, Czech Republic.
245    12
$a A modular Geant4 model of Leksell Gamma Knife Perfexion™ / $c J. Pipek, J. Novotný, J. Novotný, P. Kozubíková,
520    9_
$a This work presents a Monte Carlo model of Leksell Gamma Knife Perfexion as well as the main parameters of the dose distribution in the standard phantom obtained using this model. The model is developed in the Geant4 simulation toolkit in a modular way which enables its reuse in other Perfexion studies. Large phase space files were created, containing particles that are entering the inner machine cavity after being transported through the collimation system. All 14 output factors of the machine and effective output factors for both the 4 mm (0.830 ± 0.009) and 8 mm (0.921 ± 0.004) collimators were calculated. Dose profiles along the main axes are also included for each collimator size. All results are compared to the values obtained from the treatment planning system, from experiments, and from other Monte Carlo models.
650    12
$a počítačová simulace $7 D003198
650    _2
$a lidé $7 D006801
650    12
$a statistické modely $7 D015233
650    12
$a metoda Monte Carlo $7 D009010
650    _2
$a nádory $x chirurgie $7 D009369
650    12
$a fantomy radiodiagnostické $7 D019047
650    _2
$a radiochirurgie $x metody $7 D016634
650    _2
$a plánování radioterapie pomocí počítače $7 D011880
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Novotný, J
700    1_
$a Novotný, J
700    1_
$a Kozubíková, P
773    0_
$w MED00003821 $t Physics in medicine and biology $x 1361-6560 $g Roč. 59, č. 24 (2014), s. 7609-23
856    41
$u https://pubmed.ncbi.nlm.nih.gov/25415510 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20160408 $b ABA008
991    __
$a 20160418100524 $b ABA008
999    __
$a ok $b bmc $g 1114123 $s 935062
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2014 $b 59 $c 24 $d 7609-23 $i 1361-6560 $m Physics in medicine and biology $n Phys Med Biol $x MED00003821
LZP    __
$a Pubmed-20160408

Find record

Citation metrics

Loading data ...

Archiving options

Loading data ...