Ohybová tuhost zubu čepovce po přední fixaci jedním tahovým šroubem - biomechanická studie
[Odontoid bending stiffness after anterior fixation with a single lag screw: biomechanical study]

P. Buchvald, L. Čapek, P. Barsa

. 2015 ; 82 (3) : 235-238.

Jazyk čeština Země Česko

Typ dokumentu anglický abstrakt, časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc16013693

Digitální knihovna NLK
Zdroj

E-zdroje Online

NLK Free Medical Journals od 2006

Odkazy

PubMed 26317296

PURPOSE OF THE STUDY The aim of the experiment was to compare the bending stiffness of an intact odontoid process with bending stiffness after its simulated type II fracture was fixed with a single lag screw. The experiment was done with a desire to answer the question of whether a single osteosynthetic screw is sufficient for good fixation of a type II odontoid fracture. MATERIAL AND METHODS The C2 vertebrae of six cadavers were used. With simultaneous measurement of odontoid bending stiffness, the occurrence of a fracture (type IIA, Grauer's modification of the Anderson- D'Alonzo classification) was simulated using action exerted by a tearing machine in the direction perpendicular to the odontoid axis. Each odontoid fracture was subsequently treated by direct osteosynthesis with a single lag screw inserted in the axial direction by a standard surgical procedure in order to provide conditions similar to those achieved by routine surgical management. The treated odontoid process was subsequently subjected to the same tearing machine loading as applied to it at the start of the experiment. The bending stiffness measured was then compared with that found before the fracture occurred. The results were statistically evaluated by the t-test for paired samples at the level of significance α = 0.05. RESULTS The average value of bending stiffness for odontoid processes of intact vertebrae at the moment of fracture occurrence was 318.3 N/mm. After single axial lag screw fixation of the fracture, the average bending stiffness for the odontoid processes treated was 331.3 N/mm. DISCUSSION Higher values of bending stiffness after screw fixation were found in all specimens and, in comparison with the values recorded before simulated fractures, the increase was statistically significant. CONCLUSIONS The results of our measurements suggest that the single lag screw fixation of a type IIA odontoid fracture will provide better stability for the fracture fragment-C2 body complex on antero-posterior perpendicular loading than can be found in intact C2 vertebrae. Key words: odontoid fracture, odontoid fixation, bending stiffness, lag screw.

Odontoid bending stiffness after anterior fixation with a single lag screw: biomechanical study

000      
00000naa a2200000 a 4500
001      
bmc16013693
003      
CZ-PrNML
005      
20160531084044.0
007      
ta
008      
160506s2015 xr ad f 000 0|cze||
009      
AR
024    7_
$2 doi $a 10.55095/achot2015/035
035    __
$a (PubMed)26317296
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a cze $b eng
044    __
$a xr
100    1_
$a Buchvald, Pavel $u Neurocentrum, Krajská nemocnice Liberec, a. s. $7 xx0195755
245    10
$a Ohybová tuhost zubu čepovce po přední fixaci jedním tahovým šroubem - biomechanická studie / $c P. Buchvald, L. Čapek, P. Barsa
246    31
$a Odontoid bending stiffness after anterior fixation with a single lag screw: biomechanical study
520    9_
$a PURPOSE OF THE STUDY The aim of the experiment was to compare the bending stiffness of an intact odontoid process with bending stiffness after its simulated type II fracture was fixed with a single lag screw. The experiment was done with a desire to answer the question of whether a single osteosynthetic screw is sufficient for good fixation of a type II odontoid fracture. MATERIAL AND METHODS The C2 vertebrae of six cadavers were used. With simultaneous measurement of odontoid bending stiffness, the occurrence of a fracture (type IIA, Grauer's modification of the Anderson- D'Alonzo classification) was simulated using action exerted by a tearing machine in the direction perpendicular to the odontoid axis. Each odontoid fracture was subsequently treated by direct osteosynthesis with a single lag screw inserted in the axial direction by a standard surgical procedure in order to provide conditions similar to those achieved by routine surgical management. The treated odontoid process was subsequently subjected to the same tearing machine loading as applied to it at the start of the experiment. The bending stiffness measured was then compared with that found before the fracture occurred. The results were statistically evaluated by the t-test for paired samples at the level of significance α = 0.05. RESULTS The average value of bending stiffness for odontoid processes of intact vertebrae at the moment of fracture occurrence was 318.3 N/mm. After single axial lag screw fixation of the fracture, the average bending stiffness for the odontoid processes treated was 331.3 N/mm. DISCUSSION Higher values of bending stiffness after screw fixation were found in all specimens and, in comparison with the values recorded before simulated fractures, the increase was statistically significant. CONCLUSIONS The results of our measurements suggest that the single lag screw fixation of a type IIA odontoid fracture will provide better stability for the fracture fragment-C2 body complex on antero-posterior perpendicular loading than can be found in intact C2 vertebrae. Key words: odontoid fracture, odontoid fixation, bending stiffness, lag screw.
650    _2
$a senioři $7 D000368
650    _2
$a biomechanika $x fyziologie $7 D001696
650    12
$a kostní šrouby $7 D001863
650    _2
$a mrtvola $7 D002102
650    _2
$a ženské pohlaví $7 D005260
650    _2
$a vnitřní fixace fraktury $x přístrojové vybavení $7 D005593
650    _2
$a lidé $7 D006801
650    _2
$a mužské pohlaví $7 D008297
650    _2
$a lidé středního věku $7 D008875
650    _2
$a dens axis $x zranění $x chirurgie $7 D009809
650    _2
$a fraktury páteře $x patofyziologie $x chirurgie $7 D016103
655    _2
$a anglický abstrakt $7 D004740
655    _2
$a časopisecké články $7 D016428
700    1_
$a Čapek, Lukáš, $d 1979- $7 mzk2007390351 $u Fakulta strojní, Technická univerzita Liberec
700    1_
$a Barsa, Pavel $7 jx20070719015 $u Neurocentrum, Krajská nemocnice Liberec, a. s.
773    0_
$w MED00011021 $t Acta chirurgiae orthopaedicae et traumatologiae Čechoslovaca $x 0001-5415 $g Roč. 82, č. 3 (2015), s. 235-238
910    __
$a ABA008 $b A 8 $c 507 $y 4 $z 0
990    __
$a 20160506 $b ABA008
991    __
$a 20160520104504 $b ABA008
999    __
$a ok $b bmc $g 1126009 $s 938105
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2015 $b 82 $c 3 $d 235-238 $i 0001-5415 $m Acta chirurgiae orthopaedicae et traumatologiae Čechoslovaca $n Acta chir. orthop. traumatol. Čechoslovaca $x MED00011021
LZP    __
$b NLK118 $a Pubmed-20160506

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...