• Something wrong with this record ?

Fractal Analysis and Hurst Parameter for Intrapartum Fetal Heart Rate Variability Analysis: A Versatile Alternative to Frequency Bands and LF/HF Ratio

M. Doret, J. Spilka, V. Chudáček, P. Gonçalves, P. Abry,

. 2015 ; 10 (8) : e0136661. [pub] 20150831

Language English Country United States

Document type Journal Article, Observational Study, Research Support, Non-U.S. Gov't

BACKGROUND: The fetal heart rate (FHR) is commonly monitored during labor to detect early fetal acidosis. FHR variability is traditionally investigated using Fourier transform, often with adult predefined frequency band powers and the corresponding LF/HF ratio. However, fetal conditions differ from adults and modify spectrum repartition along frequencies. AIMS: This study questions the arbitrariness definition and relevance of the frequency band splitting procedure, and thus of the calculation of the underlying LF/HF ratio, as efficient tools for characterizing intrapartum FHR variability. STUDY DESIGN: The last 30 minutes before delivery of the intrapartum FHR were analyzed. SUBJECTS: Case-control study. A total of 45 singletons divided into two groups based on umbilical cord arterial pH: the Index group with pH ≤ 7.05 (n = 15) and Control group with pH > 7.05 (n = 30). OUTCOME MEASURES: Frequency band-based LF/HF ratio and Hurst parameter. RESULTS: This study shows that the intrapartum FHR is characterized by fractal temporal dynamics and promotes the Hurst parameter as a potential marker of fetal acidosis. This parameter preserves the intuition of a power frequency balance, while avoiding the frequency band splitting procedure and thus the arbitrary choice of a frequency separating bands. The study also shows that extending the frequency range covered by the adult-based bands to higher and lower frequencies permits the Hurst parameter to achieve better performance for identifying fetal acidosis. CONCLUSIONS: The Hurst parameter provides a robust and versatile tool for quantifying FHR variability, yields better acidosis detection performance compared to the LF/HF ratio, and avoids arbitrariness in spectral band splitting and definitions.

References provided by Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc16020337
003      
CZ-PrNML
005      
20160722120027.0
007      
ta
008      
160722s2015 xxu f 000 0|eng||
009      
AR
024    7_
$a 10.1371/journal.pone.0136661 $2 doi
024    7_
$a 10.1371/journal.pone.0136661 $2 doi
035    __
$a (PubMed)26322889
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xxu
100    1_
$a Doret, Muriel $u Department of Obstetrics and Gynaecology, Hospices Civils de Lyon, Hôpital Femme-Mère-Enfant, Bron, France.
245    10
$a Fractal Analysis and Hurst Parameter for Intrapartum Fetal Heart Rate Variability Analysis: A Versatile Alternative to Frequency Bands and LF/HF Ratio / $c M. Doret, J. Spilka, V. Chudáček, P. Gonçalves, P. Abry,
520    9_
$a BACKGROUND: The fetal heart rate (FHR) is commonly monitored during labor to detect early fetal acidosis. FHR variability is traditionally investigated using Fourier transform, often with adult predefined frequency band powers and the corresponding LF/HF ratio. However, fetal conditions differ from adults and modify spectrum repartition along frequencies. AIMS: This study questions the arbitrariness definition and relevance of the frequency band splitting procedure, and thus of the calculation of the underlying LF/HF ratio, as efficient tools for characterizing intrapartum FHR variability. STUDY DESIGN: The last 30 minutes before delivery of the intrapartum FHR were analyzed. SUBJECTS: Case-control study. A total of 45 singletons divided into two groups based on umbilical cord arterial pH: the Index group with pH ≤ 7.05 (n = 15) and Control group with pH > 7.05 (n = 30). OUTCOME MEASURES: Frequency band-based LF/HF ratio and Hurst parameter. RESULTS: This study shows that the intrapartum FHR is characterized by fractal temporal dynamics and promotes the Hurst parameter as a potential marker of fetal acidosis. This parameter preserves the intuition of a power frequency balance, while avoiding the frequency band splitting procedure and thus the arbitrary choice of a frequency separating bands. The study also shows that extending the frequency range covered by the adult-based bands to higher and lower frequencies permits the Hurst parameter to achieve better performance for identifying fetal acidosis. CONCLUSIONS: The Hurst parameter provides a robust and versatile tool for quantifying FHR variability, yields better acidosis detection performance compared to the LF/HF ratio, and avoids arbitrariness in spectral band splitting and definitions.
650    _2
$a acidóza $x krev $7 D000138
650    _2
$a asfyxie novorozenců $x diagnóza $7 D001238
650    _2
$a studie případů a kontrol $7 D016022
650    _2
$a ženské pohlaví $7 D005260
650    _2
$a fetální krev $x fyziologie $7 D005312
650    12
$a monitorování plodu $7 D005323
650    _2
$a fraktály $7 D017709
650    _2
$a srdeční frekvence plodu $x fyziologie $7 D006340
650    _2
$a lidé $7 D006801
650    _2
$a novorozenec $7 D007231
650    _2
$a porodní děj $7 D007743
650    _2
$a těhotenství $7 D011247
655    _2
$a časopisecké články $7 D016428
655    _2
$a pozorovací studie $7 D064888
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Spilka, Jiří $u Physics Department, CNRS, ENS Lyon, France; Czech Institute of Informatics, Robotics and Cybernetics, Czech Technical University in Prague, Prague, Czech Republic.
700    1_
$a Chudáček, Václav $u Czech Institute of Informatics, Robotics and Cybernetics, Czech Technical University in Prague, Prague, Czech Republic.
700    1_
$a Gonçalves, Paulo $u Computer Science Department, INRIA, ENS Lyon, France.
700    1_
$a Abry, Patrice $u Physics Department, CNRS, ENS Lyon, France. $7 gn_A_00000854
773    0_
$w MED00180950 $t PloS one $x 1932-6203 $g Roč. 10, č. 8 (2015), s. e0136661
856    41
$u https://pubmed.ncbi.nlm.nih.gov/26322889 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20160722 $b ABA008
991    __
$a 20160722120241 $b ABA008
999    __
$a ok $b bmc $g 1155007 $s 944865
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2015 $b 10 $c 8 $d e0136661 $e 20150831 $i 1932-6203 $m PLoS One $n PLoS One $x MED00180950
LZP    __
$a Pubmed-20160722

Find record

Citation metrics

Loading data ...

Archiving options

Loading data ...