Je něco špatně v tomto záznamu ?
Delivery of heliox with a semi-closed circuit during spontaneous breathing: a comparative economic theoretical study
I. Jurickova, K. Roubík, M. Muller,
Jazyk angličtina Země Anglie, Velká Británie
Typ dokumentu srovnávací studie, časopisecké články, práce podpořená grantem
Grantová podpora
NT14473
MZ0
CEP - Centrální evidence projektů
Digitální knihovna NLK
Plný text - Článek
Zdroj
NLK
BioMedCentral
od 2001-12-01
BioMedCentral Open Access
od 2001
Directory of Open Access Journals
od 2001
Free Medical Journals
od 2001
PubMed Central
od 2001
Europe PubMed Central
od 2001
ProQuest Central
od 2009-01-01
Open Access Digital Library
od 2001-01-01
Open Access Digital Library
od 2001-01-01
Open Access Digital Library
od 2001-09-01
Medline Complete (EBSCOhost)
od 2001-01-01
Health & Medicine (ProQuest)
od 2009-01-01
ROAD: Directory of Open Access Scholarly Resources
od 2001
Springer Nature OA/Free Journals
od 2001-12-01
- MeSH
- anesteziologický okruh ekonomika přístrojové vybavení MeSH
- ekonomické modely MeSH
- helium aplikace a dávkování ekonomika MeSH
- kyslík aplikace a dávkování ekonomika MeSH
- lidé MeSH
- náklady a analýza nákladů MeSH
- obstrukce dýchacích cest ekonomika terapie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- srovnávací studie MeSH
BACKGROUND: Heliox is a mixture of oxygen and helium which reduces airway resistance in patients with airway obstruction. In clinical practice, patients breathing spontaneously receive heliox via an open circuit. Recently, a semi-closed circuit for heliox administration has been proposed which minimizes consumption of heliox and therefore cost of the heliox therapy; although, the semi-closed circuit is associated with additional costs. The aim of the study is to conduct an economical analysis comparing total cost of heliox therapy using an open versus a semi-closed circuit in spontaneously breathing patients with airway obstruction. METHODS: Four different systems for heliox administration were analyzed: an open circuit and three alternatives of a semi-closed circuit involving a custom made semi-closed circuit and two standard anesthesia machines. Total costs of heliox therapy were calculated for all the systems. For calculation of gas consumption, the clinical procedures limiting continuous heliox therapy including the aerosol therapy, personal hygiene and nutrition were taken into account. A sensitivity analysis was conducted for main input variables that may influence the results of the study. RESULTS: Price of gases consumed by a semi-closed system represents less than 20 % of price of gases when a standard open circuit is used. This represents a saving of approximately 540 EUR per patient. The initial cost of the custom-made semi-closed circuit recuperates after treatment of 18 patients. The corresponding number of patients is 32 when a low-cost anesthesia machine is initially acquired and rises to 69 when a highly advanced anesthesia machine is considered. CONCLUSIONS: Heliox therapy in spontaneously breathing patients using a semi-closed circuit becomes more cost-effective compared to the open circuit, currently used in clinical practice, when applied in a sufficient number of cases. The impact of finding a cheaper way of heliox administration on the clinical practice needs to be ascertained.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc16020696
- 003
- CZ-PrNML
- 005
- 20171205143055.0
- 007
- ta
- 008
- 160722s2015 enk f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1186/s12890-015-0060-9 $2 doi
- 024 7_
- $a 10.1186/s12890-015-0060-9 $2 doi
- 035 __
- $a (PubMed)26059111
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a enk
- 100 1_
- $a Kubátová, Ivana $7 jo2014841294 $u Department of Biomedical Technology, Faculty of Biomedical Engineering, Czech Technical University in Prague, Prague, Czech Republic. ivana.jurickova@fbmi.cvut.cz.
- 245 10
- $a Delivery of heliox with a semi-closed circuit during spontaneous breathing: a comparative economic theoretical study / $c I. Jurickova, K. Roubík, M. Muller,
- 520 9_
- $a BACKGROUND: Heliox is a mixture of oxygen and helium which reduces airway resistance in patients with airway obstruction. In clinical practice, patients breathing spontaneously receive heliox via an open circuit. Recently, a semi-closed circuit for heliox administration has been proposed which minimizes consumption of heliox and therefore cost of the heliox therapy; although, the semi-closed circuit is associated with additional costs. The aim of the study is to conduct an economical analysis comparing total cost of heliox therapy using an open versus a semi-closed circuit in spontaneously breathing patients with airway obstruction. METHODS: Four different systems for heliox administration were analyzed: an open circuit and three alternatives of a semi-closed circuit involving a custom made semi-closed circuit and two standard anesthesia machines. Total costs of heliox therapy were calculated for all the systems. For calculation of gas consumption, the clinical procedures limiting continuous heliox therapy including the aerosol therapy, personal hygiene and nutrition were taken into account. A sensitivity analysis was conducted for main input variables that may influence the results of the study. RESULTS: Price of gases consumed by a semi-closed system represents less than 20 % of price of gases when a standard open circuit is used. This represents a saving of approximately 540 EUR per patient. The initial cost of the custom-made semi-closed circuit recuperates after treatment of 18 patients. The corresponding number of patients is 32 when a low-cost anesthesia machine is initially acquired and rises to 69 when a highly advanced anesthesia machine is considered. CONCLUSIONS: Heliox therapy in spontaneously breathing patients using a semi-closed circuit becomes more cost-effective compared to the open circuit, currently used in clinical practice, when applied in a sufficient number of cases. The impact of finding a cheaper way of heliox administration on the clinical practice needs to be ascertained.
- 650 _2
- $a obstrukce dýchacích cest $x ekonomika $x terapie $7 D000402
- 650 _2
- $a anesteziologický okruh $x ekonomika $x přístrojové vybavení $7 D000764
- 650 _2
- $a náklady a analýza nákladů $7 D003365
- 650 _2
- $a helium $x aplikace a dávkování $x ekonomika $7 D006371
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a ekonomické modely $7 D018803
- 650 _2
- $a kyslík $x aplikace a dávkování $x ekonomika $7 D010100
- 655 _2
- $a srovnávací studie $7 D003160
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Roubík, Karel, $u Department of Biomedical Technology, Faculty of Biomedical Engineering, Czech Technical University in Prague, Prague, Czech Republic. roubik@fbmi.cvut.cz. $d 1971- $7 ntka173892
- 700 1_
- $a Muller, Martin $u Department of Biomedical Technology, Faculty of Biomedical Engineering, Czech Technical University in Prague, Prague, Czech Republic. martin.muller@uvn.cz. Department of Anesthesiology, Resuscitation and Intensive Care Medicine, First Faculty of Medicine Charles University in Prague and the Military University Hospital in Prague, Prague, Czech Republic. martin.muller@uvn.cz.
- 773 0_
- $w MED00008206 $t BMC pulmonary medicine $x 1471-2466 $g Roč. 15, č. - (2015), s. 65
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/26059111 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20160722 $b ABA008
- 991 __
- $a 20171205143232 $b ABA008
- 999 __
- $a ok $b bmc $g 1155366 $s 945224
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2015 $b 15 $c - $d 65 $e 20150610 $i 1471-2466 $m BMC pulmonary medicine $n BMC Pulm Med $x MED00008206
- GRA __
- $a NT14473 $p MZ0
- LZP __
- $a Pubmed-20160722