A study to establish international diagnostic reference levels for paediatric computed tomography

J. Vassileva, M. Rehani, D. Kostova-Lefterova, HM. Al-Naemi, JS. Al Suwaidi, D. Arandjic, EH. Bashier, S. Kodlulovich Renha, L. El-Nachef, JG. Aguilar, V. Gershan, E. Gershkevitsh, E. Gruppetta, A. Hustuc, A. Jauhari, MH. Kharita, N....

. 2015 ; 165 (1-4) : 70-80. [pub] 20150401

Jazyk angličtina Země Anglie, Velká Británie

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc16020901

The article reports results from the largest international dose survey in paediatric computed tomography (CT) in 32 countries and proposes international diagnostic reference levels (DRLs) in terms of computed tomography dose index (CTDI vol) and dose length product (DLP). It also assesses whether mean or median values of individual facilities should be used. A total of 6115 individual patient data were recorded among four age groups: <1 y, >1-5 y, >5-10 y and >10-15 y. CTDIw, CTDI vol and DLP from the CT console were recorded in dedicated forms together with patient data and technical parameters. Statistical analysis was performed, and international DRLs were established at rounded 75th percentile values of distribution of median values from all CT facilities. The study presents evidence in favour of using median rather than mean of patient dose indices as the representative of typical local dose in a facility, and for establishing DRLs as third quartile of median values. International DRLs were established for paediatric CT examinations for routine head, chest and abdomen in the four age groups. DRLs for CTDI vol are similar to the reference values from other published reports, with some differences for chest and abdomen CT. Higher variations were observed between DLP values, based on a survey of whole multi-phase exams. It may be noted that other studies in literature were based on single phase only. DRLs reported in this article can be used in countries without sufficient medical physics support to identify non-optimised practice. Recommendations to improve the accuracy and importance of future surveys are provided.

Al Sabah Hospital Kuwait City Kuwait

Atomic Energy Commission of Syria Damascus Syria

Centro de Investigación en Ciencias Atómicas Nucleares y Moleculares Universidad de Costa Rica San José Costa Rica

Children Clinical University Hospital Riga Latvia

Clinical Radiology Institute University Medical Center Ljubljana Slovenia

Département de Physique Médicale Centre de Recherche Nucléaire D'Alger Algiers Algiers

Department of Radiology The National Hospital of Sri Lanka Colombo Sri Lanka

Faculty of Medicine Department of Radiology Chiang Mai University Chiang Mai Thailand

Hamad Medical Corp Doha Qatar

Harvard Medical School and Massachusetts General Hospital Boston USA

Hospital of Lithuanian University of Health Science Kauno Klinikos Kaunas Lithuania

Institute of Nuclear Medicine and Oncology PAEC Lahore Pakistan

Institute of Physics Ss Cyril and Methodius University Skopje The former Yugoslav Republic of Macedonia

International Atomic Energy Agency Vienna Austria

Lebanese Atomic Eneregy Commission Beirut Lebanon

Mater Dei Hospital TalQroqq Msida Malta

Medical Education Department Dubai Health Authority Dubai UAE

Ministry of Health Malaysia Putrajaya Wilayah Persekutuan Malaysia

Ministry of Health Medical Technology and Infrastructure Administration Jerusalem Israel

National Centre of Public Health Chisinau Republic of Moldova

National Centre of Radiobiology and Radiation Protection Sofia Bulgaria

National Institute for Nuclear Research Carretera Mexico Toluca La Marquesa Ocoyoacac Mexico

National Nuclear Energy Commission Rio de Janeiro Brazil

National Radiation Protection Department Iranian Nuclear Regulatory Authority Tehran Iran

National Radiation Protection Institute Prague Czech Republic

North Estonia Medical Centre Tallinn Estonia

Pusat Kajian Radiografi dan Imajing Depok Indonesia

Radiation Protection Department Vinca Institute of Nuclear Sciences Belgrade Serbia

Radiologist Ministry of Health Yangon Myanmar

Research Center of Radiation Medicine and Burns Yerevan Armenia

Slovak Medical University Limbova Bratislava Slovakia

State Office for Radiological and Nuclear Safety Zagreb Croatia

Sudan Atomic Energy Commission Khartoum Sudan

Tanzania Atomic Energy Commission Arusha Tanzania

Universidade Federal de Pernambuco Cidade Universitaria Recife PE Brazil

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc16020901
003      
CZ-PrNML
005      
20160722121434.0
007      
ta
008      
160722s2015 enk f 000 0|eng||
009      
AR
024    7_
$a 10.1093/rpd/ncv116 $2 doi
024    7_
$a 10.1093/rpd/ncv116 $2 doi
035    __
$a (PubMed)25836685
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a enk
100    1_
$a Vassileva, J $u International Atomic Energy Agency, Vienna, Austria j.vassileva@iaea.org.
245    12
$a A study to establish international diagnostic reference levels for paediatric computed tomography / $c J. Vassileva, M. Rehani, D. Kostova-Lefterova, HM. Al-Naemi, JS. Al Suwaidi, D. Arandjic, EH. Bashier, S. Kodlulovich Renha, L. El-Nachef, JG. Aguilar, V. Gershan, E. Gershkevitsh, E. Gruppetta, A. Hustuc, A. Jauhari, MH. Kharita, N. Khelassi-Toutaoui, HR. Khosravi, H. Khoury, I. Kralik, S. Mahere, J. Mazuoliene, P. Mora, W. Muhogora, P. Muthuvelu, D. Nikodemova, L. Novak, A. Pallewatte, D. Pekarovič, M. Shaaban, E. Shelly, K. Stepanyan, N. Thelsy, P. Visrutaratna, A. Zaman,
520    9_
$a The article reports results from the largest international dose survey in paediatric computed tomography (CT) in 32 countries and proposes international diagnostic reference levels (DRLs) in terms of computed tomography dose index (CTDI vol) and dose length product (DLP). It also assesses whether mean or median values of individual facilities should be used. A total of 6115 individual patient data were recorded among four age groups: <1 y, >1-5 y, >5-10 y and >10-15 y. CTDIw, CTDI vol and DLP from the CT console were recorded in dedicated forms together with patient data and technical parameters. Statistical analysis was performed, and international DRLs were established at rounded 75th percentile values of distribution of median values from all CT facilities. The study presents evidence in favour of using median rather than mean of patient dose indices as the representative of typical local dose in a facility, and for establishing DRLs as third quartile of median values. International DRLs were established for paediatric CT examinations for routine head, chest and abdomen in the four age groups. DRLs for CTDI vol are similar to the reference values from other published reports, with some differences for chest and abdomen CT. Higher variations were observed between DLP values, based on a survey of whole multi-phase exams. It may be noted that other studies in literature were based on single phase only. DRLs reported in this article can be used in countries without sufficient medical physics support to identify non-optimised practice. Recommendations to improve the accuracy and importance of future surveys are provided.
650    _2
$a mladiství $7 D000293
650    _2
$a dítě $7 D002648
650    _2
$a předškolní dítě $7 D002675
650    _2
$a ženské pohlaví $7 D005260
650    _2
$a průzkumy zdravotní péče $7 D019538
650    _2
$a lidé $7 D006801
650    _2
$a kojenec $7 D007223
650    _2
$a novorozenec $7 D007231
650    _2
$a internacionalita $7 D038622
650    _2
$a mužské pohlaví $7 D008297
650    _2
$a pediatrie $x normy $7 D010372
650    _2
$a dávka záření $7 D011829
650    _2
$a radiační expozice $x normy $x statistika a číselné údaje $7 D000069079
650    _2
$a monitorování radiace $x normy $x statistika a číselné údaje $7 D011834
650    _2
$a referenční hodnoty $7 D012016
650    _2
$a počítačová rentgenová tomografie $x normy $x statistika a číselné údaje $7 D014057
655    _2
$a časopisecké články $7 D016428
700    1_
$a Rehani, M $u Harvard Medical School and Massachusetts General Hospital, Boston, USA.
700    1_
$a Kostova-Lefterova, D $u National Centre of Radiobiology and Radiation Protection, Sofia, Bulgaria.
700    1_
$a Al-Naemi, H M $u Hamad Medical Corp, Doha, Qatar. $7 gn_A_00004670
700    1_
$a Al Suwaidi, J S $u Medical Education Department, Dubai Health Authority, Dubai, UAE. $7 gn_A_00003188
700    1_
$a Arandjic, D $u Radiation Protection Department, Vinca Institute of Nuclear Sciences, Belgrade, Serbia. $7 gn_A_00007986
700    1_
$a Bashier, E H O $u Sudan Atomic Energy Commission, Khartoum, Sudan.
700    1_
$a Kodlulovich Renha, S $u National Nuclear Energy Commission, Rio de Janeiro, Brazil.
700    1_
$a El-Nachef, L $u Lebanese Atomic Eneregy Commission, Beirut, Lebanon.
700    1_
$a Aguilar, J G $u National Institute for Nuclear Research, Carretera Mexico-Toluca, La Marquesa, Ocoyoacac, Mexico. $7 gn_A_00002307
700    1_
$a Gershan, V $u Institute of Physics, Ss Cyril and Methodius University, Skopje, The former Yugoslav Republic of Macedonia.
700    1_
$a Gershkevitsh, E $u North Estonia Medical Centre, Tallinn, Estonia.
700    1_
$a Gruppetta, E $u Mater Dei Hospital, TalQroqq, Msida, Malta.
700    1_
$a Hustuc, A $u National Centre of Public Health, Chisinau, Republic of Moldova.
700    1_
$a Jauhari, A $u Pusat Kajian Radiografi dan Imajing, Depok, Indonesia.
700    1_
$a Kharita, Mohammad Hassan $u Atomic Energy Commission of Syria, Damascus, Syria.
700    1_
$a Khelassi-Toutaoui, N $u Département de Physique Médicale, Centre de Recherche Nucléaire D'Alger, Algiers, Algiers.
700    1_
$a Khosravi, H R $u National Radiation Protection Department, Iranian Nuclear Regulatory Authority, Tehran, Iran.
700    1_
$a Khoury, H $u Universidade Federal de Pernambuco, Cidade Universitaria, Recife PE, Brazil.
700    1_
$a Kralik, I $u State Office for Radiological and Nuclear Safety, Zagreb, Croatia.
700    1_
$a Mahere, S $u Children Clinical University Hospital, Riga, Latvia.
700    1_
$a Mazuoliene, J $u Hospital of Lithuanian University of Health Science Kauno Klinikos, Kaunas, Lithuania.
700    1_
$a Mora, P $u Centro de Investigación en Ciencias Atómicas, Nucleares y Moleculares, Universidad de Costa Rica, San José, Costa Rica.
700    1_
$a Muhogora, W $u Tanzania Atomic Energy Commission, Arusha, Tanzania.
700    1_
$a Muthuvelu, P $u Ministry of Health Malaysia, Putrajaya Wilayah Persekutuan, Malaysia.
700    1_
$a Nikodemova, D $u Slovak Medical University, Limbova, Bratislava, Slovakia.
700    1_
$a Novak, L $u National Radiation Protection Institute, Prague, Czech Republic.
700    1_
$a Pallewatte, A $u Department of Radiology, The National Hospital of Sri Lanka, Colombo, Sri Lanka.
700    1_
$a Pekarovič, D $u Clinical Radiology Institute, University Medical Center, Ljubljana, Slovenia.
700    1_
$a Shaaban, M $u Al-Sabah Hospital, Kuwait City, Kuwait.
700    1_
$a Shelly, E $u Ministry of Health, Medical Technology and Infrastructure Administration, Jerusalem, Israel.
700    1_
$a Stepanyan, K $u Research Center of Radiation Medicine and Burns, Yerevan, Armenia.
700    1_
$a Thelsy, N $u Radiologist Ministry of Health, Yangon, Myanmar.
700    1_
$a Visrutaratna, P $u Faculty of Medicine, Department of Radiology, Chiang Mai University, Chiang Mai, Thailand.
700    1_
$a Zaman, A $u Institute of Nuclear Medicine and Oncology, PAEC, Lahore, Pakistan.
773    0_
$w MED00004029 $t Radiation protection dosimetry $x 1742-3406 $g Roč. 165, č. 1-4 (2015), s. 70-80
856    41
$u https://pubmed.ncbi.nlm.nih.gov/25836685 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20160722 $b ABA008
991    __
$a 20160722121648 $b ABA008
999    __
$a ok $b bmc $g 1155571 $s 945429
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2015 $b 165 $c 1-4 $d 70-80 $e 20150401 $i 1742-3406 $m Radiation protection dosimetry $n Radiat Prot Dosimetry $x MED00004029
LZP    __
$a Pubmed-20160722

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...