-
Je něco špatně v tomto záznamu ?
The diameter of nanotubes formed on Ti-6Al-4V alloy controls the adhesion and differentiation of Saos-2 cells
E. Filova, J. Fojt, M. Kryslova, H. Moravec, L. Joska, L. Bacakova,
Jazyk angličtina Země Nový Zéland
Typ dokumentu časopisecké články, práce podpořená grantem
Grantová podpora
NT13297
MZ0
CEP - Centrální evidence projektů
Digitální knihovna NLK
Plný text - Článek
Zdroj
NLK
Directory of Open Access Journals
od 2006
Free Medical Journals
od 2006
PubMed Central
od 2006
Europe PubMed Central
od 2006
ProQuest Central
od 2012-01-01
Open Access Digital Library
od 2006-01-01
Open Access Digital Library
od 2009-01-01
Taylor & Francis Open Access
od 2006-09-01
Medline Complete (EBSCOhost)
od 2012-01-01
Health & Medicine (ProQuest)
od 2012-01-01
ROAD: Directory of Open Access Scholarly Resources
od 2006
PubMed
26648719
DOI
10.2147/ijn.s87474
Knihovny.cz E-zdroje
- MeSH
- aktiny metabolismus MeSH
- biologické markery metabolismus MeSH
- buněčná adheze účinky léků MeSH
- buněčná diferenciace účinky léků MeSH
- fluorescenční protilátková technika MeSH
- fotoelektronová spektroskopie MeSH
- lidé MeSH
- nádorové buněčné linie MeSH
- nanotrubičky chemie MeSH
- osteoblasty cytologie účinky léků MeSH
- osteogeneze účinky léků MeSH
- povrchové vlastnosti MeSH
- proliferace buněk účinky léků MeSH
- titan farmakologie MeSH
- velikost částic * MeSH
- viabilita buněk účinky léků MeSH
- vinkulin metabolismus MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
Ti-6Al-4V-based nanotubes were prepared on a Ti-6Al-4V surface by anodic oxidation on 10 V, 20 V, and 30 V samples. The 10 V, 20 V, and 30 V samples and a control smooth Ti-6Al-4V sample were evaluated in terms of their chemical composition, diameter distribution, and cellular response. The surfaces of the 10 V, 20 V, and 30 V samples consisted of nanotubes of a relatively wide range of diameters that increased with the voltage. Saos-2 cells had a similar initial adhesion on all nanotube samples to the control Ti-6Al-4V sample, but it was lower than on glass. On day 3, the highest concentrations of both vinculin and talin measured by enzyme-linked immunosorbent assay and intensity of immunofluorescence staining were on 30 V nanotubes. On the other hand, the highest concentrations of ALP, type I collagen, and osteopontin were found on 10 V and 20 V samples. The final cellular densities on 10 V, 20 V, and 30 V samples were higher than on glass. Therefore, the controlled anodization of Ti-6Al-4V seems to be a useful tool for preparing nanostructured materials with desirable biological properties.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc16027858
- 003
- CZ-PrNML
- 005
- 20191127093126.0
- 007
- ta
- 008
- 161005s2015 nz f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.2147/IJN.S87474 $2 doi
- 024 7_
- $a 10.2147/IJN.S87474 $2 doi
- 035 __
- $a (PubMed)26648719
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a nz
- 100 1_
- $a Filová, Elena, $u Department of Biomaterials and Tissue Engineering, Institute of Physiology, Czech Academy of Sciences, Prague, Czech Republic. $7 xx0074200 $d 1973-
- 245 14
- $a The diameter of nanotubes formed on Ti-6Al-4V alloy controls the adhesion and differentiation of Saos-2 cells / $c E. Filova, J. Fojt, M. Kryslova, H. Moravec, L. Joska, L. Bacakova,
- 520 9_
- $a Ti-6Al-4V-based nanotubes were prepared on a Ti-6Al-4V surface by anodic oxidation on 10 V, 20 V, and 30 V samples. The 10 V, 20 V, and 30 V samples and a control smooth Ti-6Al-4V sample were evaluated in terms of their chemical composition, diameter distribution, and cellular response. The surfaces of the 10 V, 20 V, and 30 V samples consisted of nanotubes of a relatively wide range of diameters that increased with the voltage. Saos-2 cells had a similar initial adhesion on all nanotube samples to the control Ti-6Al-4V sample, but it was lower than on glass. On day 3, the highest concentrations of both vinculin and talin measured by enzyme-linked immunosorbent assay and intensity of immunofluorescence staining were on 30 V nanotubes. On the other hand, the highest concentrations of ALP, type I collagen, and osteopontin were found on 10 V and 20 V samples. The final cellular densities on 10 V, 20 V, and 30 V samples were higher than on glass. Therefore, the controlled anodization of Ti-6Al-4V seems to be a useful tool for preparing nanostructured materials with desirable biological properties.
- 650 _2
- $a aktiny $x metabolismus $7 D000199
- 650 _2
- $a biologické markery $x metabolismus $7 D015415
- 650 _2
- $a buněčná adheze $x účinky léků $7 D002448
- 650 _2
- $a buněčná diferenciace $x účinky léků $7 D002454
- 650 _2
- $a nádorové buněčné linie $7 D045744
- 650 _2
- $a proliferace buněk $x účinky léků $7 D049109
- 650 _2
- $a viabilita buněk $x účinky léků $7 D002470
- 650 _2
- $a fluorescenční protilátková technika $7 D005455
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a nanotrubičky $x chemie $7 D043942
- 650 _2
- $a osteoblasty $x cytologie $x účinky léků $7 D010006
- 650 _2
- $a osteogeneze $x účinky léků $7 D010012
- 650 12
- $a velikost částic $7 D010316
- 650 _2
- $a fotoelektronová spektroskopie $7 D056951
- 650 _2
- $a povrchové vlastnosti $7 D013499
- 650 _2
- $a titan $x farmakologie $7 D014025
- 650 _2
- $a vinkulin $x metabolismus $7 D016596
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Fojt, Jaroslav $u Department of Metals and Corrosion Engineering, University of Chemistry and Technology, Prague, Czech Republic. $7 _AN077081
- 700 1_
- $a Krýslová, Markéta $u Department of Biomaterials and Tissue Engineering, Institute of Physiology, Czech Academy of Sciences, Prague, Czech Republic.
- 700 1_
- $a Moravec, Hynek $u Department of Metals and Corrosion Engineering, University of Chemistry and Technology, Prague, Czech Republic. $7 _AN077080
- 700 1_
- $a Joska, Luděk $u Department of Metals and Corrosion Engineering, University of Chemistry and Technology, Prague, Czech Republic. $7 xx0103993
- 700 1_
- $a Bačáková, Lucie, $u Department of Biomaterials and Tissue Engineering, Institute of Physiology, Czech Academy of Sciences, Prague, Czech Republic. $d 1958- $7 xx0070525
- 773 0_
- $w MED00176143 $t International journal of nanomedicine $x 1178-2013 $g Roč. 10, č. - (2015), s. 7145-7163
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/26648719 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20161005 $b ABA008
- 991 __
- $a 20191127093412 $b ABA008
- 999 __
- $a ok $b bmc $g 1166172 $s 952488
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2015 $b 10 $c - $d 7145-7163 $e 20151120 $i 1178-2013 $m International journal of nanomedicine $n Int J Nanomedicine $x MED00176143
- GRA __
- $a NT13297 $p MZ0
- LZP __
- $a Pubmed-20161005