-
Je něco špatně v tomto záznamu ?
HILIC-MS Determination of Genotoxic Impurity of 2-Chloro-N-(2-Chloroethyl)Ethanamine in the Vortioxetine Manufacturing Process
M. Douša, R. Klvaňa, J. Doubský, J. Srbek, J. Richter, M. Exner, P. Gibala,
Jazyk angličtina Země Spojené státy americké
Typ dokumentu hodnotící studie, časopisecké články
PubMed
26223463
DOI
10.1093/chromsci/bmv107
Knihovny.cz E-zdroje
- MeSH
- hmotnostní spektrometrie metody MeSH
- kontaminace léku * MeSH
- mutageny analýza MeSH
- piperaziny analýza MeSH
- sulfidy analýza MeSH
- vysokoúčinná kapalinová chromatografie metody MeSH
- Publikační typ
- časopisecké články MeSH
- hodnotící studie MeSH
In the last decade, pharmaceutical regulatory agencies are focused on monitoring and evaluation of trace-level genotoxic impurities (GTIs) in drug substances, which requires manufacturers to deliver innovative approaches for their analysis and control. GTIs in the low p.p.m. level rising from the process of drug production have to be positively identified and quantified. Therefore, sensitive and selective analytical methods are necessary for required quantification level of these GTIs. Unfortunately, general guidance on how to develop strategy of the analysis and control of GTIs is currently missing in the pharmaceutical industry. Therefore, practical example of the analytical control of 2-chloro-N-(2-chloroethyl)ethanamine GTI in the vortioxetine (VOR) manufacturing process was demonstrated in this work. QDa mass detection with electrospray ionization in selected-ion recording mode was utilized for quantitation of GTIs. The method of hydrophilic interaction liquid chromatography coupled with mass spectrometry detection (HILIC-MS) was validated as per International Conference on Harmonization guidelines and was able to quantitate GTIs at 75 p.p.m. with respect to VOR. The HILIC-MS method was achieved using a Primesep B column (150 × 4.6 mm, 5.0 µm; Sielc, USA) using mobile phase consisting of 10 mM ammonium formate buffer pH 3.0 and acetonitrile (5 : 95, v/v) at 0.8 mL/min flow rate. The QDa mass detector was operated in the positive ion mode. Quadrupole mass analyzer was employed in selected-ion monitoring mode using target ion at m/z 142 as [M+H](+).
Waters Gesellschaft m b H Psohlavců 43 147 00 Prague 4 Czech Republic
Zentiva k s Praha a Sanofi Company U Kabelovny 130 102 37 Prague 10 Czech Republic
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc17001077
- 003
- CZ-PrNML
- 005
- 20170119095943.0
- 007
- ta
- 008
- 170103s2016 xxu f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1093/chromsci/bmv107 $2 doi
- 024 7_
- $a 10.1093/chromsci/bmv107 $2 doi
- 035 __
- $a (PubMed)26223463
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xxu
- 100 1_
- $a Douša, Michal $u Zentiva, k.s. Praha, a Sanofi Company, U Kabelovny 130, 102 37 Prague 10, Czech Republic michal.dousa@seznam.cz.
- 245 10
- $a HILIC-MS Determination of Genotoxic Impurity of 2-Chloro-N-(2-Chloroethyl)Ethanamine in the Vortioxetine Manufacturing Process / $c M. Douša, R. Klvaňa, J. Doubský, J. Srbek, J. Richter, M. Exner, P. Gibala,
- 520 9_
- $a In the last decade, pharmaceutical regulatory agencies are focused on monitoring and evaluation of trace-level genotoxic impurities (GTIs) in drug substances, which requires manufacturers to deliver innovative approaches for their analysis and control. GTIs in the low p.p.m. level rising from the process of drug production have to be positively identified and quantified. Therefore, sensitive and selective analytical methods are necessary for required quantification level of these GTIs. Unfortunately, general guidance on how to develop strategy of the analysis and control of GTIs is currently missing in the pharmaceutical industry. Therefore, practical example of the analytical control of 2-chloro-N-(2-chloroethyl)ethanamine GTI in the vortioxetine (VOR) manufacturing process was demonstrated in this work. QDa mass detection with electrospray ionization in selected-ion recording mode was utilized for quantitation of GTIs. The method of hydrophilic interaction liquid chromatography coupled with mass spectrometry detection (HILIC-MS) was validated as per International Conference on Harmonization guidelines and was able to quantitate GTIs at 75 p.p.m. with respect to VOR. The HILIC-MS method was achieved using a Primesep B column (150 × 4.6 mm, 5.0 µm; Sielc, USA) using mobile phase consisting of 10 mM ammonium formate buffer pH 3.0 and acetonitrile (5 : 95, v/v) at 0.8 mL/min flow rate. The QDa mass detector was operated in the positive ion mode. Quadrupole mass analyzer was employed in selected-ion monitoring mode using target ion at m/z 142 as [M+H](+).
- 650 _2
- $a vysokoúčinná kapalinová chromatografie $x metody $7 D002851
- 650 12
- $a kontaminace léku $7 D004340
- 650 _2
- $a hmotnostní spektrometrie $x metody $7 D013058
- 650 _2
- $a mutageny $x analýza $7 D009153
- 650 _2
- $a piperaziny $x analýza $7 D010879
- 650 _2
- $a sulfidy $x analýza $7 D013440
- 655 _2
- $a hodnotící studie $7 D023362
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Klvaňa, Robert $u Zentiva, k.s. Praha, a Sanofi Company, U Kabelovny 130, 102 37 Prague 10, Czech Republic.
- 700 1_
- $a Doubský, Jan $u Zentiva, k.s. Praha, a Sanofi Company, U Kabelovny 130, 102 37 Prague 10, Czech Republic.
- 700 1_
- $a Srbek, Jan $u Zentiva, k.s. Praha, a Sanofi Company, U Kabelovny 130, 102 37 Prague 10, Czech Republic.
- 700 1_
- $a Richter, Jindřich $u Zentiva, k.s. Praha, a Sanofi Company, U Kabelovny 130, 102 37 Prague 10, Czech Republic.
- 700 1_
- $a Exner, Marek $u Waters Gesellschaft m.b.H, Psohlavců 43, 147 00 Prague 4, Czech Republic.
- 700 1_
- $a Gibala, Petr $u Zentiva, k.s. Praha, a Sanofi Company, U Kabelovny 130, 102 37 Prague 10, Czech Republic.
- 773 0_
- $w MED00002734 $t Journal of chromatographic science $x 1945-239X $g Roč. 54, č. 2 (2016), s. 119-24
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/26223463 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20170103 $b ABA008
- 991 __
- $a 20170119100052 $b ABA008
- 999 __
- $a ok $b bmc $g 1180217 $s 961644
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2016 $b 54 $c 2 $d 119-24 $e 20150729 $i 1945-239X $m Journal of chromatographic science $n J Chromatogr Sci $x MED00002734
- LZP __
- $a Pubmed-20170103