-
Something wrong with this record ?
Geometric ring annuloplasty as an adjunct to aortic valve repair: clinical investigation of the HAART 300 device
D. Mazzitelli, T. Fischlein, JS. Rankin, YH. Choi, C. Stamm, S. Pfeiffer, J. Pirk, C. Detter, J. Kroll, F. Beyersdorf, CD. Griffin, M. Shrestha, C. Nöbauer, PS. Crooke, C. Schreiber, R. Lange,
Language English Country Germany
Document type Clinical Trial, Journal Article, Research Support, Non-U.S. Gov't
NLK
Free Medical Journals
from 1987
Medline Complete (EBSCOhost)
from 2012-11-01 to 1 year ago
PubMed
26156945
DOI
10.1093/ejcts/ezv234
Knihovny.cz E-resources
- MeSH
- Cardiac Valve Annuloplasty adverse effects instrumentation methods mortality MeSH
- Aortic Valve surgery MeSH
- Aortic Valve Insufficiency surgery MeSH
- Adult MeSH
- Middle Aged MeSH
- Humans MeSH
- Prospective Studies MeSH
- Reoperation MeSH
- Aged, 80 and over MeSH
- Aged MeSH
- Heart Valve Prosthesis adverse effects MeSH
- Check Tag
- Adult MeSH
- Middle Aged MeSH
- Humans MeSH
- Male MeSH
- Aged, 80 and over MeSH
- Aged MeSH
- Female MeSH
- Publication type
- Journal Article MeSH
- Clinical Trial MeSH
- Research Support, Non-U.S. Gov't MeSH
OBJECTIVES: This study assessed the safety and efficacy of an internal geometric annuloplasty ring in a regulatory trial of aortic valve reconstruction (ClinicalTrials.gov Identifier: NCT01400841). METHODS: Sixty-five patients with predominant moderate-to-severe trileaflet aortic insufficiency (AI) underwent aortic valve repair with an average age of 63 ± 13 years (mean ± SD). All had initial implantation of an internal aortic annuloplasty ring to correct annular dilatation and facilitate leaflet reconstruction. Leaflet plication was performed for prolapse in 80% of patients, and more complex leaflet procedures, usually employing autologous pericardium, were required in 22%. Ascending aortic and/or root aneurysms were replaced in 62%. RESULTS: Follow-up was for a maximum of 3 years and a mean of 2 years. No in-hospital operative mortalities, major complications or early or late valve-related events occurred. The annular diameter before repair was 26.5 ± 2.3 mm, and the average ring diameter used was 21.5 ± 1.6 mm. The preoperative AI grade (0-4) was 2.9 ± 0.8 and improved after repair to 0.6 ± 0.7 (P < 0.0001), as did the NYHA class. The mean valve gradient was 8.6 ± 4.3 mmHg, and at 3 years, the Kaplan-Meier survival rate was 95%, with no valve-related mortality. Over the 3 years, aortic valve replacement was required in 7 patients (10.8%) for reasons usually related to surgical technique. Most repair failures occurred early, and results stabilized after 6 months. No structural complications of the rings were observed. CONCLUSIONS: Geometric ring annuloplasty was a safe and effective adjunct to aortic valve repair. Initial correction of annular dilatation seemed to facilitate overall reconstruction. Because most early repair failures were technical, increasing experience with geometric ring annuloplasty for aortic valve reconstruction has the potential to standardize and improve outcomes.
BioStable Science and Engineering Inc Austin TX USA
Cardiothoracic Surgery Associates Nashville TN USA
Department of Cardiac and Thoracic Surgery University of Köln Cologne Germany
Department of Cardiac Surgery Deutsches Herzzentrum Berlin Berlin Germany
Department of Cardiac Surgery Institute for Clinical and Experimental Medicine Prague Czech Republic
Department of Cardiothoracic Surgery Hannover Medical School Hannover Germany
Department of Cardiovascular Surgery Albert Ludwigs University Freiburg Germany
Department of Cardiovascular Surgery Deutsches Herzzentrum München Munich Germany
Department of Cardiovascular Surgery University Heart Center Hamburg Germany
Department of Mathematics Vanderbilt University Nashville TN USA
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc17001101
- 003
- CZ-PrNML
- 005
- 20230302135622.0
- 007
- ta
- 008
- 170103s2016 gw f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1093/ejcts/ezv234 $2 doi
- 024 7_
- $a 10.1093/ejcts/ezv234 $2 doi
- 035 __
- $a (PubMed)26156945
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a gw
- 100 1_
- $a Mazzitelli, Domenico $u Department of Cardiovascular Surgery, Deutsches Herzzentrum München, Munich, Germany.
- 245 10
- $a Geometric ring annuloplasty as an adjunct to aortic valve repair: clinical investigation of the HAART 300 device / $c D. Mazzitelli, T. Fischlein, JS. Rankin, YH. Choi, C. Stamm, S. Pfeiffer, J. Pirk, C. Detter, J. Kroll, F. Beyersdorf, CD. Griffin, M. Shrestha, C. Nöbauer, PS. Crooke, C. Schreiber, R. Lange,
- 520 9_
- $a OBJECTIVES: This study assessed the safety and efficacy of an internal geometric annuloplasty ring in a regulatory trial of aortic valve reconstruction (ClinicalTrials.gov Identifier: NCT01400841). METHODS: Sixty-five patients with predominant moderate-to-severe trileaflet aortic insufficiency (AI) underwent aortic valve repair with an average age of 63 ± 13 years (mean ± SD). All had initial implantation of an internal aortic annuloplasty ring to correct annular dilatation and facilitate leaflet reconstruction. Leaflet plication was performed for prolapse in 80% of patients, and more complex leaflet procedures, usually employing autologous pericardium, were required in 22%. Ascending aortic and/or root aneurysms were replaced in 62%. RESULTS: Follow-up was for a maximum of 3 years and a mean of 2 years. No in-hospital operative mortalities, major complications or early or late valve-related events occurred. The annular diameter before repair was 26.5 ± 2.3 mm, and the average ring diameter used was 21.5 ± 1.6 mm. The preoperative AI grade (0-4) was 2.9 ± 0.8 and improved after repair to 0.6 ± 0.7 (P < 0.0001), as did the NYHA class. The mean valve gradient was 8.6 ± 4.3 mmHg, and at 3 years, the Kaplan-Meier survival rate was 95%, with no valve-related mortality. Over the 3 years, aortic valve replacement was required in 7 patients (10.8%) for reasons usually related to surgical technique. Most repair failures occurred early, and results stabilized after 6 months. No structural complications of the rings were observed. CONCLUSIONS: Geometric ring annuloplasty was a safe and effective adjunct to aortic valve repair. Initial correction of annular dilatation seemed to facilitate overall reconstruction. Because most early repair failures were technical, increasing experience with geometric ring annuloplasty for aortic valve reconstruction has the potential to standardize and improve outcomes.
- 650 _2
- $a dospělí $7 D000328
- 650 _2
- $a senioři $7 D000368
- 650 _2
- $a senioři nad 80 let $7 D000369
- 650 _2
- $a aortální chlopeň $x chirurgie $7 D001021
- 650 _2
- $a aortální insuficience $x chirurgie $7 D001022
- 650 _2
- $a anuloplastika srdeční chlopně $x škodlivé účinky $x přístrojové vybavení $x metody $x mortalita $7 D058385
- 650 _2
- $a ženské pohlaví $7 D005260
- 650 _2
- $a srdeční chlopně umělé $x škodlivé účinky $7 D006350
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a mužské pohlaví $7 D008297
- 650 _2
- $a lidé středního věku $7 D008875
- 650 _2
- $a prospektivní studie $7 D011446
- 650 _2
- $a reoperace $7 D012086
- 655 _2
- $a klinické zkoušky $7 D016430
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Fischlein, Theodor $u Department of Cardiovascular Surgery, Klinikum Nürnberg, Paracelsus Medical University, Nuremberg, Germany.
- 700 1_
- $a Rankin, J Scott $u Cardiothoracic Surgery Associates, Nashville, TN, USA jsrankinmd@cs.com.
- 700 1_
- $a Choi, Yeong-Hoon $u Department of Cardiac and Thoracic Surgery, University of Köln, Cologne, Germany.
- 700 1_
- $a Stamm, Christof $u Department of Cardiac Surgery, Deutsches Herzzentrum Berlin, Berlin, Germany.
- 700 1_
- $a Pfeiffer, Steffen $u Department of Cardiovascular Surgery, Klinikum Nürnberg, Paracelsus Medical University, Nuremberg, Germany.
- 700 1_
- $a Pirk, Jan $u Department of Cardiac Surgery, Institute for Clinical and Experimental Medicine, Prague, Czech Republic.
- 700 1_
- $a Detter, Christian $u Department of Cardiovascular Surgery, University Heart Center, Hamburg, Germany.
- 700 1_
- $a Kroll, Johannes $u Department of Cardiovascular Surgery, Albert-Ludwigs University, Freiburg, Germany.
- 700 1_
- $a Beyersdorf, Friedhelm $u Department of Cardiovascular Surgery, Albert-Ludwigs University, Freiburg, Germany.
- 700 1_
- $a Griffin, Charles D $u BioStable Science and Engineering, Inc., Austin, TX, USA.
- 700 1_
- $a Shrestha, Malakh $u Department of Cardiothoracic Surgery, Hannover Medical School, Hannover, Germany.
- 700 1_
- $a Nöbauer, Christian $u Department of Cardiovascular Surgery, Deutsches Herzzentrum München, Munich, Germany.
- 700 1_
- $a Crooke, Philip S $u Department of Mathematics, Vanderbilt University, Nashville, TN, USA.
- 700 1_
- $a Schreiber, Christian $u Department of Cardiovascular Surgery, Deutsches Herzzentrum München, Munich, Germany.
- 700 1_
- $a Lange, Rüdiger, $u Department of Cardiovascular Surgery, Deutsches Herzzentrum München, Munich, Germany. $d 1953- $7 xx0282824
- 773 0_
- $w MED00001607 $t European journal of cardio-thoracic surgery $x 1873-734X $g Roč. 49, č. 3 (2016), s. 987-93
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/26156945 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20170103 $b ABA008
- 991 __
- $a 20230302135616 $b ABA008
- 999 __
- $a ok $b bmc $g 1180241 $s 961668
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2016 $b 49 $c 3 $d 987-93 $e 20150708 $i 1873-734X $m European journal of cardio-thoracic surgery $n Eur J Cardiothorac Surg $x MED00001607
- LZP __
- $a Pubmed-20170103