Colorimetric sensor based on bubble wrap and camera phone for glucose determination

Pavla Martinkova, Miroslav Pohanka

. 2016 ; 14 (4) : 315-319.

Jazyk angličtina Země Česko

Perzistentní odkaz   https://www.medvik.cz/link/bmc17012169

Glucose is a typical marker of diabetes mellitus but it corresponds also with metabolic syndrome, immune disorders and some types of poisoning. Hence fast, low cost and simple method for its determination is required. Bubble wrap, cheap and available material, was used for immobilization of glucose oxidase (GOx) and peroxidase (POx), the enzymes necessary for colorimetric determination of glucose. Method is based on reaction of enzymes (immobilized in sol-gel membrane inside the bubbles) with substrates glucose and o-phenylenediamine dihydrochloride (o-PD) providing intensive coloration. The color change can be easily tracked by phone integrated camera. Color intensity expressed in red-green-blue (RGB) color model was used for displaying of photos and for gaining numeric data representing concentrations of glucose. The assay exerted good correlation of color intensity with the concentration of glucose, adequately low limit of detection (750 mmol/l) for glucose blood assay, no influence of interferents or matrix substances and by sufficient long term stability of sol-gel membrane. The sensor was found as low-cost simple way to analyze glucose blood levels with promising prospects in the field of portable devices.

Citace poskytuje Crossref.org

Bibliografie atd.

Literatura

000      
00000naa a2200000 a 4500
001      
bmc17012169
003      
CZ-PrNML
005      
20170601113914.0
007      
ta
008      
170407s2016 xr ad f 000 0|eng||
009      
AR
024    7_
$a 10.1016/j.jab.2016.05.003 $2 doi
040    __
$a ABA008 $d ABA008 $e AACR2 $b cze
041    0_
$a eng
044    __
$a xr
100    1_
$a Martínková, Pavla $7 _AN086247 $u Faculty of Military Health Sciences, University of Defense, Brno, Trebesska 1575, 50001 Hradec Kralove, Czech Republic
245    10
$a Colorimetric sensor based on bubble wrap and camera phone for glucose determination / $c Pavla Martinkova, Miroslav Pohanka
504    __
$a Literatura
520    9_
$a Glucose is a typical marker of diabetes mellitus but it corresponds also with metabolic syndrome, immune disorders and some types of poisoning. Hence fast, low cost and simple method for its determination is required. Bubble wrap, cheap and available material, was used for immobilization of glucose oxidase (GOx) and peroxidase (POx), the enzymes necessary for colorimetric determination of glucose. Method is based on reaction of enzymes (immobilized in sol-gel membrane inside the bubbles) with substrates glucose and o-phenylenediamine dihydrochloride (o-PD) providing intensive coloration. The color change can be easily tracked by phone integrated camera. Color intensity expressed in red-green-blue (RGB) color model was used for displaying of photos and for gaining numeric data representing concentrations of glucose. The assay exerted good correlation of color intensity with the concentration of glucose, adequately low limit of detection (750 mmol/l) for glucose blood assay, no influence of interferents or matrix substances and by sufficient long term stability of sol-gel membrane. The sensor was found as low-cost simple way to analyze glucose blood levels with promising prospects in the field of portable devices.
650    _2
$a krevní glukóza $x analýza $7 D001786
650    12
$a biosenzitivní techniky $x metody $7 D015374
650    _2
$a glukosaoxidasa $7 D005949
650    _2
$a peroxidasa $7 D009195
650    _2
$a reagenční diagnostické soupravy $7 D011933
650    _2
$a kolorimetrie $x metody $x přístrojové vybavení $7 D003124
650    _2
$a plastické hmoty $7 D010969
650    _2
$a gely $7 D005782
650    _2
$a indikátory a reagencie $7 D007202
650    _2
$a fotografování $7 D010781
650    _2
$a membrány umělé $7 D008567
700    1_
$a Pohanka, Miroslav $7 hka2010563580 $u Faculty of Military Health Sciences, University of Defense, Brno, Trebesska 1575, 50001 Hradec Kralove, Czech Republic
773    0_
$t Journal of applied biomedicine $x 1214-021X $g Roč. 14, č. 4 (2016), s. 315-319 $w MED00012667
856    41
$u https://jab.zsf.jcu.cz/pdfs/jab/2016/04/08.pdf $y plný text volně přístupný
910    __
$a ABA008 $b B 2301 $c 1249 $y 4 $z 0
990    __
$a 20170407165523 $b ABA008
991    __
$a 20170601114316 $b ABA008
999    __
$a ok $b bmc $g 1198037 $s 972937
BAS    __
$a 3
BMC    __
$a 2016 $b 14 $c 4 $d 315-319 $i 1214-021X $m Journal of Applied Biomedicine $x MED00012667
LZP    __
$c NLK125 $d 20170601 $a NLK 2017-15/dk

Najít záznam

Citační ukazatele

Pouze přihlášení uživatelé

Možnosti archivace

Nahrávání dat ...