Je něco špatně v tomto záznamu ?
Colorimetric sensor based on bubble wrap and camera phone for glucose determination
Pavla Martinkova, Miroslav Pohanka
Jazyk angličtina Země Česko
- MeSH
- biosenzitivní techniky * metody MeSH
- fotografování MeSH
- gely MeSH
- glukosaoxidasa MeSH
- indikátory a reagencie MeSH
- kolorimetrie metody přístrojové vybavení MeSH
- krevní glukóza analýza MeSH
- membrány umělé MeSH
- peroxidasa MeSH
- plastické hmoty MeSH
- reagenční diagnostické soupravy MeSH
Glucose is a typical marker of diabetes mellitus but it corresponds also with metabolic syndrome, immune disorders and some types of poisoning. Hence fast, low cost and simple method for its determination is required. Bubble wrap, cheap and available material, was used for immobilization of glucose oxidase (GOx) and peroxidase (POx), the enzymes necessary for colorimetric determination of glucose. Method is based on reaction of enzymes (immobilized in sol-gel membrane inside the bubbles) with substrates glucose and o-phenylenediamine dihydrochloride (o-PD) providing intensive coloration. The color change can be easily tracked by phone integrated camera. Color intensity expressed in red-green-blue (RGB) color model was used for displaying of photos and for gaining numeric data representing concentrations of glucose. The assay exerted good correlation of color intensity with the concentration of glucose, adequately low limit of detection (750 mmol/l) for glucose blood assay, no influence of interferents or matrix substances and by sufficient long term stability of sol-gel membrane. The sensor was found as low-cost simple way to analyze glucose blood levels with promising prospects in the field of portable devices.
Citace poskytuje Crossref.org
Literatura
- 000
- 00000naa a2200000 a 4500
- 001
- bmc17012169
- 003
- CZ-PrNML
- 005
- 20170601113914.0
- 007
- ta
- 008
- 170407s2016 xr ad f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1016/j.jab.2016.05.003 $2 doi
- 040 __
- $a ABA008 $d ABA008 $e AACR2 $b cze
- 041 0_
- $a eng
- 044 __
- $a xr
- 100 1_
- $a Martínková, Pavla $7 _AN086247 $u Faculty of Military Health Sciences, University of Defense, Brno, Trebesska 1575, 50001 Hradec Kralove, Czech Republic
- 245 10
- $a Colorimetric sensor based on bubble wrap and camera phone for glucose determination / $c Pavla Martinkova, Miroslav Pohanka
- 504 __
- $a Literatura
- 520 9_
- $a Glucose is a typical marker of diabetes mellitus but it corresponds also with metabolic syndrome, immune disorders and some types of poisoning. Hence fast, low cost and simple method for its determination is required. Bubble wrap, cheap and available material, was used for immobilization of glucose oxidase (GOx) and peroxidase (POx), the enzymes necessary for colorimetric determination of glucose. Method is based on reaction of enzymes (immobilized in sol-gel membrane inside the bubbles) with substrates glucose and o-phenylenediamine dihydrochloride (o-PD) providing intensive coloration. The color change can be easily tracked by phone integrated camera. Color intensity expressed in red-green-blue (RGB) color model was used for displaying of photos and for gaining numeric data representing concentrations of glucose. The assay exerted good correlation of color intensity with the concentration of glucose, adequately low limit of detection (750 mmol/l) for glucose blood assay, no influence of interferents or matrix substances and by sufficient long term stability of sol-gel membrane. The sensor was found as low-cost simple way to analyze glucose blood levels with promising prospects in the field of portable devices.
- 650 _2
- $a krevní glukóza $x analýza $7 D001786
- 650 12
- $a biosenzitivní techniky $x metody $7 D015374
- 650 _2
- $a glukosaoxidasa $7 D005949
- 650 _2
- $a peroxidasa $7 D009195
- 650 _2
- $a reagenční diagnostické soupravy $7 D011933
- 650 _2
- $a kolorimetrie $x metody $x přístrojové vybavení $7 D003124
- 650 _2
- $a plastické hmoty $7 D010969
- 650 _2
- $a gely $7 D005782
- 650 _2
- $a indikátory a reagencie $7 D007202
- 650 _2
- $a fotografování $7 D010781
- 650 _2
- $a membrány umělé $7 D008567
- 700 1_
- $a Pohanka, Miroslav $7 hka2010563580 $u Faculty of Military Health Sciences, University of Defense, Brno, Trebesska 1575, 50001 Hradec Kralove, Czech Republic
- 773 0_
- $t Journal of applied biomedicine $x 1214-021X $g Roč. 14, č. 4 (2016), s. 315-319 $w MED00012667
- 856 41
- $u https://jab.zsf.jcu.cz/pdfs/jab/2016/04/08.pdf $y plný text volně přístupný
- 910 __
- $a ABA008 $b B 2301 $c 1249 $y 4 $z 0
- 990 __
- $a 20170407165523 $b ABA008
- 991 __
- $a 20170601114316 $b ABA008
- 999 __
- $a ok $b bmc $g 1198037 $s 972937
- BAS __
- $a 3
- BMC __
- $a 2016 $b 14 $c 4 $d 315-319 $i 1214-021X $m Journal of Applied Biomedicine $x MED00012667
- LZP __
- $c NLK125 $d 20170601 $a NLK 2017-15/dk