-
Je něco špatně v tomto záznamu ?
Performance comparison of three trypsin columns used in liquid chromatography
T. Šlechtová, M. Gilar, K. Kalíková, SM. Moore, JW. Jorgenson, E. Tesařová,
Jazyk angličtina Země Nizozemsko
Typ dokumentu časopisecké články
- MeSH
- chromatografie kapalinová * přístrojové vybavení metody MeSH
- enzymy imobilizované * chemie metabolismus MeSH
- trypsin * chemie metabolismus MeSH
- Publikační typ
- časopisecké články MeSH
Trypsin is the most widely used enzyme in proteomic research due to its high specificity. Although the in-solution digestion is predominantly used, it has several drawbacks, such as long digestion times, autolysis, and intolerance to high temperatures or organic solvents. To overcome these shortcomings trypsin was covalently immobilized on solid support and tested for its proteolytic activity. Trypsin was immobilized on bridge-ethyl hybrid silica sorbent with 300Å pores, packed in 2.1×30mm column and compared with Perfinity and Poroszyme trypsin columns. Catalytic efficiency of enzymatic reactors was tested using Nα-Benzoyl-l-arginine 4-nitroanilide hydrochloride as a substrate. The impact of buffer pH, mobile phase flow rate, and temperature on enzymatic activity was investigated. Digestion speed generally increased with the temperature from 20 to 37°C. Digestion speed also increased with pH from 7.0 to 9.0; the activity of prototype enzyme reactor was highest at pH 9.0, when it activity exceeded both commercial reactors. Preliminary data for fast protein digestion are presented.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc17023283
- 003
- CZ-PrNML
- 005
- 20170720123131.0
- 007
- ta
- 008
- 170720s2017 ne f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1016/j.chroma.2017.02.024 $2 doi
- 035 __
- $a (PubMed)28215403
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a ne
- 100 1_
- $a Šlechtová, Tereza $u Department of Physical and Macromolecular Chemistry, Faculty of Science, Charles University, Hlavova 8, 128 43, Prague, Czechia.
- 245 10
- $a Performance comparison of three trypsin columns used in liquid chromatography / $c T. Šlechtová, M. Gilar, K. Kalíková, SM. Moore, JW. Jorgenson, E. Tesařová,
- 520 9_
- $a Trypsin is the most widely used enzyme in proteomic research due to its high specificity. Although the in-solution digestion is predominantly used, it has several drawbacks, such as long digestion times, autolysis, and intolerance to high temperatures or organic solvents. To overcome these shortcomings trypsin was covalently immobilized on solid support and tested for its proteolytic activity. Trypsin was immobilized on bridge-ethyl hybrid silica sorbent with 300Å pores, packed in 2.1×30mm column and compared with Perfinity and Poroszyme trypsin columns. Catalytic efficiency of enzymatic reactors was tested using Nα-Benzoyl-l-arginine 4-nitroanilide hydrochloride as a substrate. The impact of buffer pH, mobile phase flow rate, and temperature on enzymatic activity was investigated. Digestion speed generally increased with the temperature from 20 to 37°C. Digestion speed also increased with pH from 7.0 to 9.0; the activity of prototype enzyme reactor was highest at pH 9.0, when it activity exceeded both commercial reactors. Preliminary data for fast protein digestion are presented.
- 650 12
- $a chromatografie kapalinová $x přístrojové vybavení $x metody $7 D002853
- 650 12
- $a enzymy imobilizované $x chemie $x metabolismus $7 D004800
- 650 12
- $a trypsin $x chemie $x metabolismus $7 D014357
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Gilar, Martin $u Waters Corporation, 34 Maple Street, Milford, MA 01757, USA. Electronic address: Martin_Gilar@waters.com.
- 700 1_
- $a Kalíková, Květa $u Department of Physical and Macromolecular Chemistry, Faculty of Science, Charles University, Hlavova 8, 128 43, Prague, Czechia.
- 700 1_
- $a Moore, Stephanie M $u Department of Chemistry, University of North Carolina at Chapel Hill, Chapel Hill, NC 27599-3290, USA.
- 700 1_
- $a Jorgenson, James W $u Department of Chemistry, University of North Carolina at Chapel Hill, Chapel Hill, NC 27599-3290, USA.
- 700 1_
- $a Tesařová, Eva $u Department of Physical and Macromolecular Chemistry, Faculty of Science, Charles University, Hlavova 8, 128 43, Prague, Czechia.
- 773 0_
- $w MED00004962 $t Journal of chromatography. A $x 1873-3778 $g Roč. 1490, č. - (2017), s. 126-132
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/28215403 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20170720 $b ABA008
- 991 __
- $a 20170720123624 $b ABA008
- 999 __
- $a ok $b bmc $g 1238964 $s 984196
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2017 $b 1490 $c - $d 126-132 $e 20170214 $i 1873-3778 $m Journal of chromatography. A, Including electrophoresis and other separation methods $n J Chromatogr A $x MED00004962
- LZP __
- $a Pubmed-20170720