Prediction of gradient retention data for hydrophilic interaction liquid chromatographic separation of native and fluorescently labeled oligosaccharides
N. Vaňková, P. Česla,
Language English Country Netherlands
Document type Journal Article
- MeSH
- Chromatography, Liquid methods MeSH
- Fluorescent Dyes chemistry MeSH
- Hydrophobic and Hydrophilic Interactions MeSH
- Naphthalenes chemistry MeSH
- Oligosaccharides chemistry isolation & purification MeSH
- ortho-Aminobenzoates chemistry MeSH
- Silicon Dioxide MeSH
- Publication type
- Journal Article MeSH
In this work, we have investigated the predictive properties of mixed-mode retention model and oligomeric mixed-mode model, taking into account the contribution of monomeric units to the retention, in hydrophilic interaction liquid chromatography. The gradient retention times of native maltooligosaccharides and their fluorescent derivatives were predicted in the oligomeric series with number of monomeric glucose units in the range from two to seven. The maltooligosaccharides were separated on a packed column with carbamoyl-bonded silica stationary phase and 15 gradient profiles with different initial and final mobile phase composition were used with the gradient times 5; 7.5 and 10min. The predicted gradient retention times were compared for calculations based on isocratic retention data and gradient retention data, which provided better accuracy of the results. By comparing two different mobile phase additives, the more accurate retention times were predicted in mobile phases containing ammonium acetate. The acidic derivatives, prepared by reaction of an oligosaccharide with 2-aminobenzoic acid or 8-aminonaphthalene-1,3,6-trisulfonic acid, provided more accurate predictions of the retention data in comparison to native oligosaccharides or their neutral derivatives. The oligomeric mixed-mode model allowed prediction of gradient retention times using only one gradient profile, which significantly speeded-up the method development.
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc17023344
- 003
- CZ-PrNML
- 005
- 20170720123134.0
- 007
- ta
- 008
- 170720s2017 ne f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1016/j.chroma.2017.01.032 $2 doi
- 035 __
- $a (PubMed)28108080
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a ne
- 100 1_
- $a Vaňková, Nikola $u Department of Analytical Chemistry, Faculty of Chemical Technology, University of Pardubice, Studentská 573, Pardubice, CZ-53210, Czechia.
- 245 10
- $a Prediction of gradient retention data for hydrophilic interaction liquid chromatographic separation of native and fluorescently labeled oligosaccharides / $c N. Vaňková, P. Česla,
- 520 9_
- $a In this work, we have investigated the predictive properties of mixed-mode retention model and oligomeric mixed-mode model, taking into account the contribution of monomeric units to the retention, in hydrophilic interaction liquid chromatography. The gradient retention times of native maltooligosaccharides and their fluorescent derivatives were predicted in the oligomeric series with number of monomeric glucose units in the range from two to seven. The maltooligosaccharides were separated on a packed column with carbamoyl-bonded silica stationary phase and 15 gradient profiles with different initial and final mobile phase composition were used with the gradient times 5; 7.5 and 10min. The predicted gradient retention times were compared for calculations based on isocratic retention data and gradient retention data, which provided better accuracy of the results. By comparing two different mobile phase additives, the more accurate retention times were predicted in mobile phases containing ammonium acetate. The acidic derivatives, prepared by reaction of an oligosaccharide with 2-aminobenzoic acid or 8-aminonaphthalene-1,3,6-trisulfonic acid, provided more accurate predictions of the retention data in comparison to native oligosaccharides or their neutral derivatives. The oligomeric mixed-mode model allowed prediction of gradient retention times using only one gradient profile, which significantly speeded-up the method development.
- 650 _2
- $a chromatografie kapalinová $x metody $7 D002853
- 650 _2
- $a fluorescenční barviva $x chemie $7 D005456
- 650 _2
- $a hydrofobní a hydrofilní interakce $7 D057927
- 650 _2
- $a naftaleny $x chemie $7 D009281
- 650 _2
- $a oligosacharidy $x chemie $x izolace a purifikace $7 D009844
- 650 _2
- $a oxid křemičitý $7 D012822
- 650 _2
- $a ortoaminobenzoáty $x chemie $7 D062367
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Česla, Petr $u Department of Analytical Chemistry, Faculty of Chemical Technology, University of Pardubice, Studentská 573, Pardubice, CZ-53210, Czechia. Electronic address: Petr.Cesla@upce.cz.
- 773 0_
- $w MED00004962 $t Journal of chromatography. A $x 1873-3778 $g Roč. 1485, č. - (2017), s. 82-89
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/28108080 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20170720 $b ABA008
- 991 __
- $a 20170720123627 $b ABA008
- 999 __
- $a ok $b bmc $g 1239025 $s 984257
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2017 $b 1485 $c - $d 82-89 $e 20170116 $i 1873-3778 $m Journal of chromatography. A, Including electrophoresis and other separation methods $n J Chromatogr A $x MED00004962
- LZP __
- $a Pubmed-20170720